Miele KF 1801 Vi Operating and Installation manual - Page 77
Plumbing 77, The shut-off valve for the water
View all Miele KF 1801 Vi manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
All plumbing work should be carried out by a suitably qualified and competent person, in accordance with all applicable local and national regulations. The water quality must conform to country requirements for drinking water. - The appliance is only suitable for connection to the cold water supply. - The water pressure must be between 25 and 120 psi (1.72-8.25 bar). - A separate shut-off valve must be installed, so that the water supply can be interrupted as needed. - The maximum outer diameter of the water pipe (without fittings): 3/8" (10 mm). The shut-off valve for the water connection must not be located behind the appliance. It is recommended to place the shut-off valve directly next to the appliance (base unit) or in another easily accessible location. Plumbing 77