Miele KF 2981 SF Operating and Installation instructions - Page 19

Side-by-side, ... with partition wall, at least, 8 16 mm, narrower than, 5/16 160 mm, thicker than

Page 19 highlights

Installation information Side-by-side This appliance can be installed side-byside with another refrigeration appliance. The following overview will show you which side-by-side options you have with your appliance: A side-by-side merging kit and a top frame (KTF) are required for this. Both are available from your Miele dealer or Miele Technical Service. Instructions for installing appliances side-by-side can be found in the sideby-side merging kit instruction manual. The appliances are secured individually in their niche using the supplied installation material. If the partition wall a is narrower than 6 5/16" (160 mm), you will need the side panel heater from the side-by-side installation kit to prevent condensation from forming and any resulting damage. If the partition wall a is thicker than 6 5/16" (160 mm), you do not need the side-by-side installation kit, nor the side panel heater. . . . without partition wall ... with partition wall The wall a between the side-by-side appliances must be at least 5/8" (16 mm) thick. If the appliances are to be installed next to each other without a partition wall between them, they will need to be joined together with the side-by-side installation kit. In addition, you must install the side panel heater to prevent condensation from forming and any resulting damage. 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Installation information
19
Side-by-side
This appliance can be installed side-by-
side with another refrigeration appli-
ance. The following overview will show
you which side-by-side options you
have with your appliance:
A side-by-side merging kit and a top
frame (KTF) are required for this. Both
are available from your Miele dealer or
Miele Technical Service.
Instructions for installing appliances
side-by-side can be found in the side-
by-side merging kit instruction man-
ual.
... with partition wall
The wall
a
between the side-by-side
appliances must be
at least
5/8" (16 mm)
thick.
The appliances are secured individually
in their niche using the supplied instal-
lation material.
If the partition wall
a
is
narrower than
6 5/16" (160 mm)
, you will need the
side panel heater from the side-by-side
installation kit to prevent condensation
from forming and any resulting damage.
If the partition wall
a
is
thicker than
6 5/16" (160 mm)
, you do not need the
side-by-side installation kit, nor the side
panel heater.
. . . without partition wall
If the appliances are to be installed next
to each other without a partition wall
between them, they will need to be
joined together with the side-by-side in-
stallation kit. In addition, you must in-
stall the side panel heater to prevent
condensation from forming and any re-
sulting damage.