Miele PT 7136 Operating and Installation manual - Page 28
Other faults, Possible fault, Solution, The program, runs too long or, stops., The laundry is - vented dryer
View all Miele PT 7136 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Frequently asked questions Other faults What if ... The program runs too long or stops. The laundry is not dry enough. Possible fault Solution In some cases "Clean out airways" is displayed. See "Settings - Supervisor level - Clean the airways". Open and close the dryer door. The air supply is insufficient. Open a window or door to increase the air flow. The lint filter is clogged with lint. Remove the lint. The exhaust hose or the - Check the exhaust parts connection is clogged with regularly (e.g. wall vent duct, lint. louvered wall vent, bends, etc.) for air permeability. - Remove the lint. The laundry was not spun Spin laundry thoroughly before sufficiently in the washer. drying. The dryer has over-loaded. Regard the maximum load size per program. Metallic zippers prevent a correct measurement of the laundry's residual moisture. - Open the zippers of the laundry before drying. If the problem persists, dry items with long zippers using the "Warm air" program. The load contained too - Continue drying using the many dissimilar items (size "Warm air" program. and fabrics.) - See the "Program Guide" for suitable programs. 28