Page 2 highlights

Connect ground wire terminal to gear case as shown. Connector terminals joining gear case assembly to PCBA of the electronics assembly are to be tucked into channel as shown with wires placed down into wire traps. Watch for pinched wires here. Be sure that all mechanical and elec- trical components are placed firmly and squarely in the corresponding cavities of left housing halve. OB Be very careful and make sure that all wires and the wire ribbon are placed firmly down in wire channels and traps. Make sure there are no interferences when installing the right housing halve. ATTENTION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES

  • 1
  • 2

Connect ground wire
terminal to gear case
as shown.
Connector terminals joining
gear case assembly to PCBA
of the electronics assembly are
to be tucked into channel as
shown with wires placed
down into wire traps.
Watch for pinched
wires here.
Be sure that all mechanical and elec-
trical components are placed firmly
and squarely in the corresponding
cavities of left housing halve.
Be very careful and make sure that all
wires and the wire ribbon are placed
firmly down in wire channels and
traps.
Make sure there are no interferences
when installing the right housing
halve.
ATTENTION
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC
SENSITIVE
DEVICES