NEC E657Q External Control Codes - Page 9

Message block format

Page 9 highlights

4.2 Message block format Header Message Check code Delimiter "Message block format" is allied to the "Message Type" in the "Header". Refer to the section 4.1 "Header block format" for more detail. 1) Get current parameter The controller sends this message when you want to get the status of the monitor. For the status that you want to get, specify the "OP code page" and "OP code", refer to "Appendix A. Operation code table". "Message format" of the "Get current parameter" is as follows, STX OP code OP code ETX page Hi Lo Hi Lo  Refer to section 5.1 "Get current parameter from a monitor." for more details. 2) Get Parameter reply The monitor will reply with the status of the requested item specified by the controller in the "Get parameter message". "Message format" of the "Get parameter reply" is as follows, STX Result OP code OP code Type Max value Current Value ETX page Hi Lo Hi Lo Hi Lo Hi Lo MSB LSB MSB LSB  Refer to section 5.2 "Get parameter reply" for more details. 3) Set parameter The controller sends this message to change a setting of the monitor. Message format of the "Set parameter" is as follows, STX OP code OP code Set Value ETX page Hi Lo Hi Lo MSB LSB  Refer to section 5.3 "Set parameter" for more details. 4) Set Parameter reply The monitor replies with this message for a confirmation of the "Set parameter message". Message format of the "Set parameter reply" is as follows, STX Result OP code OP code Type Max value Requested setting ETX page Value Hi Lo Hi Lo Hi Lo Hi Lo MSB LSB MSB LSB  Refer to section 5.4 "Set parameter reply" for more details. 5) Command "Command message" format depends on each command. Usually, this "command message" is used for some non-slider controls and some special operations, such as "Get timing report", "power control", etc. Refer to section 5.5 "Commands message" for (9/47)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

(9/47)
4.2 Message block format
Message block format
is allied to the
Message Type
in the
Header
.
Refer to the section 4.1
Header block format
for more detail.
1) Get current parameter
The controller sends this message when you want to get the status of the monitor.
For the status that you want to get, specify the
OP code page
and
OP code
,
refer to
Appendix A. Operation code table
.
Message format
of the
Get current parameter
is as follows,
Refer to section 5.1
Get current parameter from a monitor.
for more details.
2) Get Parameter reply
The monitor will reply with the status of the requested item specified by the controller
in the
Get parameter message
.
Message format
of the
Get parameter reply
is as follows,
Refer to section 5.2
Get parameter reply
for more details.
3) Set parameter
The controller sends this message to change a setting of the monitor.
Message format of the
Set parameter
is as follows,
Refer to section 5.3
Set parameter
for more details.
4) Set Parameter reply
The monitor replies with this message for a confirmation of the
Set parameter message
.
Message format of the
Set parameter reply
is as follows,
Refer to section 5.4
Set parameter reply
for more details.
5) Command
Command message
format depends on each command.
Usually, this
command message
is used for some non-slider controls and some special operations,
such as
Get timing report
,
power control
, etc. Refer to section 5.5
Commands message
for
Header
Message
Check code
Delimiter
STX
OP code
page
OP code
ETX
Hi
Lo
Hi
Lo
STX
Result
OP code
page
OP code
Type
Max value
Current Value
ETX
Hi
Lo Hi
Lo
Hi
Lo
Hi
Lo
MSB
LSB
MSB
LSB
STX
OP code
page
OP code
Set Value
ETX
Hi Lo
Hi
Lo
MSB
LSB
STX
Result
OP code
page
OP code
Type
Max value
Requested setting
Value
ETX
Hi Lo Hi Lo Hi Lo Hi Lo MSB
LSB
MSB