Standby Mode setting for receiving commands

Page 3 highlights

2. Standby Mode setting for receiving commands The Standby Mode setting that can receive commands is different depending on the model. Please see the table below. Target command: "015. POWER ON" ■Projector Model name NP-M402W / NP-M362W / NP-M402X / NP-M362X / NP-M322X / NP-M282X / NP-M322W / NP-M352WS / NP-M302WS / NP-M332XS NP-PA622U / NP-PA522U / NP-PA672W / NP-PA572W / NP-PA722X / NP-PA622X NP-PA621U / NP-PA521U / NP-PA671W / NP-PA571W / NP-PA721X / NP-PA621X NP-PH1202HL / PH1002HL NP-PX651X / NP-PX581W NP-PX602UL / PX602WL NP-U321H NP-UM301X / NP-UM301W / NP-UM361X / NP-UM351W NP-UM352W Setting of the Standby Mode When connected using a serial cable When connected using via a wired LAN NORMAL, NETWORK STANDBY NETWORK STANDBY NORMAL, HTBaseT STANDBY HTBaseT STANDBY NORMAL, NETWORK STANDBY NORMAL, NETWORK STANDBY NORMAL, NETWORK STANDBY NORMAL, NETWORK STANDBY NORMAL(Standard), NETWORK STANDBY NORMAL, NETWORK STANDBY NETWORK STANDBY NETWORK STANDBY NETWORK STANDBY NETWORK STANDBY NETWORK STANDBY NETWORK STANDBY 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

2. Standby Mode setting for receiving commands
The Standby Mode setting that can receive commands is different depending on the model.
Please see the table below.
Target command: "015. POWER ON"
Projector
Model name
When connected using a serial cable
When connected using via a wired LAN
NP-M402W / NP-M362W / NP-M402X / NP-M362X / NP-M322X /
NP-M282X / NP-M322W / NP-M352WS / NP-M302WS / NP-M332XS
NORMAL, NETWORK STANDBY
NETWORK STANDBY
NP-PA622U / NP-PA522U / NP-PA672W / NP-PA572W /
NP-PA722X / NP-PA622X
NORMAL, HTBaseT STANDBY
HTBaseT STANDBY
NP-PA621U / NP-PA521U / NP-PA671W / NP-PA571W /
NP-PA721X / NP-PA621X
NORMAL, NETWORK STANDBY
NETWORK STANDBY
NP-PH1202HL / PH1002HL
NORMAL, NETWORK STANDBY
NETWORK STANDBY
NP-PX651X / NP-PX581W
NORMAL, NETWORK STANDBY
NETWORK STANDBY
NP-PX602UL / PX602WL
NORMAL, NETWORK STANDBY
NETWORK STANDBY
NP-U321H
NORMAL(Standard), NETWORK STANDBY
NETWORK STANDBY
NP-UM301X / NP-UM301W / NP-UM361X / NP-UM351W
NP-UM352W
NORMAL, NETWORK STANDBY
NETWORK STANDBY
Setting of the Standby Mode