111. AUTO ADJUST EXECUTE2 Function: This command executes the Auto Adjust. Command: 03H BAH 00H 00H 01H 00H BEH Response: At the time of a success 23H BAH 01H xxH 01H 00H CKS (*1) (*2) (*3) Response: At the time of a failure A3H BAH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 305-1. BASE MODEL TYPE REQUEST Function: This command acquires the projector type. Command: 00H BFH 00H 00H 01H 00H C0H Response: At the time of a success 20H BFH 01H xxH 10H DATA01 ... DATA16 CKS (*1) (*2) (*3) Data Portion Contents DATA01 00H fixed DATA02 ... 03 Projector type See DATA13...14 DATA04 ... 12 Model name (NULL termination character string) DATA13 ... 14 Projector type
![](/manual_guide/products/nec-np115-np115-rs232-codes-projectors-c793467/50.png)
111. AUTO ADJUST EXECUTE2
**********************************************************************
Function:
This command executes the Auto Adjust.
Command:
03H
BAH
00H
00H
01H
00H
BEH
Response: At the time of a success
23H
BAH
01H
xxH
01H
00H
CKS
(*1)
(*2)
(*3)
Response: At the time of a failure
A3H
BAH
01H
xxH
02H
DATA01
DATA02
CKS
(*1)
(*2)
(*4)
(*3)
305-1. BASE MODEL TYPE REQUEST
**********************************************************************
Function:
This command acquires the projector type.
Command:
00H
BFH
00H
00H
01H
00H
C0H
Response: At the time of a success
20H
BFH
01H
xxH
10H
DATA01 ... DATA16
CKS
(*1)
(*2)
(*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01
00H fixed
DATA02 ... 03
Projector type
See DATA13...14
DATA04 ... 12
Model name (NULL termination character string)
DATA13 ... 14
Projector type