039. LAMP MODE SET Function: This command sets the lamp mode of projector. Command: 03H B1H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 07H fixed DATA02 Setting Value 00H : Normal 01H : Eco Response: At the time of a success 23H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 046. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of projector. Command: 03H B0H 00H 00H 01H C3H 77H Response: At the time of a success 23H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 C3H fixed DATA02 Setting Value 00H : OFF 01H : ON Response: At the time of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3)