NEC NP-PA550W-13ZL PA Series Installation Guide - Page 5

NEC Display Solutions of America, Inc.

Page 5 highlights

NEC Display Solutions of America, Inc. PA500U/PA500X/PA550W/PA600X Installation Guide Desktop and Ceiling Mount Rev 1.7 Ceiling Mount Installation X C 6.92 Screen Top 0.1H Shift Range Screen Center H ONLY FOR LENSES: NP12ZL: X = 9.23" NP13ZL: X = 9.51" NP14ZL: X = 9.03" NP15ZL: X = 9.00" Desktop Installation No Offset From Mount Pipe X = Distance from lens to mount center C = Distance from lens to screen ONLY FOR NP12ZL, NP13ZL, NP14ZL AND NP15ZL LENSES Shift Range Screen Center C Note: Lens Shift Feature is not available to NP11FL. This lens should only be used for "zero degree"/"no-offset" applications. See below C 3.53 Screen Center www.necdisplay.com PA500U/PA500X/PA550W/PA600X Page 5 of 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13

NEC Display Solutions of America, Inc.
PA500U/PA500X/PA550W/PA600X Installation Guide
Desktop and Ceiling Mount
Rev 1.7
www.necdisplay.com
PA500U/PA500X/PA550W/PA600X
Page 5 of 13
Ceiling Mount Installation
Desktop Installation
Note:
Lens Shift Feature is not available to NP11FL.
This lens should only be used for “zero degree”/”no-offset” applications.
See
below
X
Shift Range
Screen Center
0.1H
6.92
No Offset From Mount Pipe
Screen Top
C
H
X = Distance from lens to mount center
NP12ZL:
X = 9.23"
NP13ZL:
X = 9.51"
NP14ZL:
X = 9.03"
NP15ZL:
X = 9.00"
C = Distance from lens to screen
ONLY FOR LENSES:
Shift Range
Screen Center
C
ONLY FOR NP12ZL, NP13ZL, NP14ZL AND NP15ZL LENSES
3.53
C
Screen Center