NEC PX-42VP5HA RS232 codes- Plasma - Page 21
PX-50XM3/50XM4/50XM5/50XM6
View all NEC PX-42VP5HA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Command: 1FH 80H 60H 6FH 00H 6EH Response: At the time of a success 7FH 60H 80H 61H 03H DATA00 DATA01 DATA02 CKS Data Portion Contents DATA00 Audio1 01H-0CH : Visual Input Data DATA01 Audio2 01H-0CH : Visual Input Data DATA02 Audio3 01H-0CH : Visual Input Data Visual Input Data 01H : VIDEO1*# 02H : VIDEO2*# 03H : VIDEO3* 04H : DVD/HD1* 05H : DVD/HD1# 05H : PC1* 06H : PC2* 06H : DVD/HD2*# 07H : PC/RGB*# 0AH : DVD (DVD1)* 0CH : HD2* 0DH : DVD2* 0EH : PC3* 0EH : DVD/HD3 (HDMI)# 0FH : DVD3 (SCART3)* 1AH : DVD/HD4 (HDMI)# • * PX-42VM4/42VP4/42VP4D/42VM5/42VP5/42VR5/42XM2/42XM3/42XM4/42XM5 • * PX-50XM3/50XM4/50XM5/50XM6 • * PX-61XM2/61XM3/61XM4/60XM5 • # PX-42XR4/42XR5/50XR5/50XR6/61XR4/60XR5 046. FAILURE MODE REQUEST Function: This command inquires the detection of any failures within the plasma. Command: 1FH 80H 60H 3FH 00H CKS Response: At the time of a success 7FH 60H 80H 3FH 02H DATA00 DATA00 CKS Data Portion Contents DATA00 Failure Mode Bit 0 : PDP MODULE 0 : Abnormal 1 : Normal Bit 1 : fixed (backup) Bit 2 : TEMPERATURE 0 : Abnormal 1 : Normal Bit 3 : FAN 0 : Abnormal