IMAGE ADJUST The position of the image can be adjusted and flickering of the image can be corrected. Example: Adjusting the vertical position On "VIDEO WALL" menu, select "IMAGE ADJUST", then press the MENU/ENTER button. The "IMAGE ADJUST" screen appears. On "V-POSITION" of "IMAGE ADJUST" menu, adjust the position. IMAGE ADJUST ASPECT MODE : NORMAL V-POSITION H-POSITION V-HEIGHT H-WIDTH AUTO PICTURE : OFF FINE PICTURE PICTURE ADJ. V-POSITION +64 SEL. ADJ. EXIT RETURN Information Ⅵ IMAGE ADJUST settings These are the same functions as the IMAGE ADJUST menu on page 22. P. ON DELAY (Power on delay) Use this function to activate power-on delay. Turn on the AUTO ID before the following operations. Example: Setting "ON" On "P. ON DELAY" of "VIDEO WALL" menu, select "ON". VIDEO WALL DIVIDER : 1 POSITION DISP. MODE : SPLIT AUTO ID : OFF IMAGE ADJUST P. ON DELAY : ON PLE LINK : OFF REPEAT TIMER : OFF SEL. ADJ. EXIT RETURN Information Ⅵ P. ON DELAY settings ON: Turns on the main power of each display after a delay time. OFF: Turns on the main power of all displays at the same time. (Only for 16 and 25 screens) MODE1: Turns on the main power of each display delayed. MODE2: Turns on the main power of each display more delayed. * Once this function has been set to "ON", the POWER ON/OFF button on the remote control does not function except for the No.1 monitor. By pressing the POWER ON button on the remote control the No.1 monitor will turn on and the others will be turned on one by one automatically. * From the second monitor onward, neither the POWER button on the unit nor the POWER ON button on the remote control works. However, by pressing and holding the POWER ON button for more than 3 seconds, the monitor will be turned on. PLE LINK Use this function to set a uniform brightness for each display. Turn on the AUTO ID and set the DIVIDER (at 1, 4 or 9) before the following operations. Example: Setting "ON" On "PLE LINK" of "VIDEO WALL" menu, select "ON", then press the MENU/ENTER button. VIDEO WALL DIVIDER : 1 POSITION DISP. MODE : SPLIT AUTO ID : OFF IMAGE ADJUST P. ON DELAY : OFF PLE LINK : ON REPEAT TIMER : OFF SEL. ADJ. EXIT RETURN Information Ⅵ PLE LINK settings ON: Sets a uniform brightness for each screen in a video wall. This can be set only when a 2×2 or 3×3 video wall is selected. OFF: Sets the individual screen brightness for each screen in a video wall. * When this function is set "ON", connect your plasma displays with the remote cable (optional) in the order of the position numbers for the 2×2 video wall. See the drawing below. * If there are changes in the DIVIDER or POSITION, the PLE LINK will automatically turn OFF. REMOTE IN No.1 No.2 No.4 No.3 Display 1 REMOTE OUT REMOTE IN No.1 No.2 No.4 No.3 Display 2 REMOTE OUT REMOTE OUT No.1 No.2 No.4 No.3 Display 4 REMOTE OUT REMOTE IN No.1 No.2 No.4 No.3 REMOTE IN Display 3 * With the 3×3 video wall, connect the final display to the first display the same way as with 2×2 video wall. Note: The remote control can be operated unless the IR REMOTE is set to "OFF". 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

33
PLE LINK
Use this function to set a uniform brightness for each
display.
Turn on the AUTO ID and set the DIVIDER (at 1, 4 or 9)
before the following operations.
Example: Setting
ON
On
PLE LINK
of
VIDEO WALL
menu, select
ON
,
then press the MENU/ENTER button.
VIDEO WALL
EXIT
DIVIDER
POSITION
DISP. MODE
AUTO ID
IMAGE ADJUST
P. ON DELAY
PLE LINK
REPEAT TIMER
:
1
:
SPLIT
:
OFF
:
OFF
:
ON
:
OFF
SEL.
RETURN
ADJ.
Information
±
PLE LINK settings
ON:
Sets a uniform brightness for each screen in a video
wall. This can be set only when a 2
×
2 or 3
×
3 video
wall is selected.
OFF:
Sets the individual screen brightness for each
screen in a video wall.
* When this function is set
ON
, connect your plasma
displays with the remote cable (optional) in the order of
the position numbers for the 2
×
2 video wall. See the
drawing below.
* If there are changes in the DIVIDER or POSITION,
the PLE LINK will automatically turn OFF.
REMOTE
IN
REMOTE
IN
REMOTE
OUT
REMOTE
OUT
REMOTE
IN
REMOTE
OUT
REMOTE
OUT
REMOTE
IN
No.1 No.2
No.3
No.4
No.1 No.2
No.3
No.4
No.1 No.2
No.3
No.4
No.1 No.2
No.3
No.4
Display 1
Display 2
Display 4
Display 3
* With the 3
×
3 video wall, connect the final display to
the first display the same way as with 2
×
2 video wall.
Note:
The remote control can be operated unless the
IR REMOTE is set to
OFF
.
IMAGE ADJUST
The position of the image can be adjusted and flickering
of the image can be corrected.
Example: Adjusting the vertical position
On
VIDEO WALL
menu, select
IMAGE ADJUST
, then
press the MENU/ENTER button.
The
IMAGE ADJUST
screen appears.
On
V-POSITION
of
IMAGE ADJUST
menu, adjust the
position.
IMAGE ADJUST
EXIT
ASPECT MODE
V-POSITION
H-POSITION
V-HEIGHT
H-WIDTH
AUTO PICTURE
FINE PICTURE
PICTURE ADJ.
:
NORMAL
:
OFF
SEL.
RETURN
ADJ.
V-POSITION
+64
Information
±
IMAGE ADJUST settings
These are the same functions as the IMAGE ADJUST
menu on page 22.
P. ON DELAY (Power on delay)
Use this function to activate power-on delay.
Turn on the AUTO ID before the following operations.
Example: Setting
ON
On
P. ON DELAY
of
VIDEO WALL
menu, select
ON
.
VIDEO WALL
EXIT
DIVIDER
POSITION
DISP. MODE
AUTO ID
IMAGE ADJUST
P. ON DELAY
PLE LINK
REPEAT TIMER
:
1
:
SPLIT
:
OFF
:
ON
:
OFF
:
OFF
SEL.
RETURN
ADJ.
Information
±
P. ON DELAY settings
ON:
Turns on the main power of each display after a
delay time.
OFF:
Turns on the main power of all displays at the
same time.
(Only for 16 and 25 screens)
MODE1:
Turns on the main power of each display
delayed.
MODE2:
Turns on the main power of each display more
delayed.
* Once this function has been set to
ON
, the POWER
ON/OFF button on the remote control does not function
except for the No.1 monitor.
By pressing the POWER ON button on the remote
control the No.1 monitor will turn on and the others
will be turned on one by one automatically.
*
From the second monitor onward, neither the POWER
button on the unit nor the POWER ON button on the
remote control works. However, by pressing and holding
the POWER ON button for more than 3 seconds, the
monitor will be turned on.