NEC SC46 MultiSync LCD SC40 SC46 User manual - Page 20

Remote Control ID Function - group

Page 20 highlights

Part Names and Functions - continued REMOTE CONTROL ID The remote control included with the display can be used to control up to 26 individual MultiSync SC monitors using what is called the REMOTE CONTROL ID mode. The REMOTE CONTROL ID mode works in conjunction with the Monitor ID, allowing control of up to 26 individual MultiSync SC monitors. For example: if there are many monitors being used in the same area, a remote control in normal mode would send signals to every monitor at the same time Figure 1. Using the remote in REMOTE CONTROL ID mode will only operate one specific monitor within the group Figure 2. TO SET REMOTE CONTROL ID: While holding down the REMOTE ID SET button on the remote control, use the KEYPAD to input the Monitor ID (1-26) of the display to be controlled via remote. The remote can then be used to operate the monitor having that specific Monitor ID number. When 0 is selected or when the remote control is in normal mode, all monitors will be operated. Remote Control ID Function Monitor ID:1 Monitor ID:2 Monitor ID:3 Remote works Remote works Remote works Figure 1 Remote in Normal mode or the REMOTE ID is set to 0 POWER GUIDE DVI VGA RGB/HV OPTION HDMI DVD/HD VIDEO TV PICTURE MODE SIZE AUDIO SOUND INPUT 1 4 7 DISPLAY 2 3 5 6 8 9 0 ENT MENU AUTO SET UP SET + EXIT VOL CH CH RTN + + MUTE STILL ON/OFF CAPTURE PIP ON/OFF INPUT CHANGE REMOTE ID SET RESET MTS SLEEP REMOTE CONTROLLER RU-M111 Monitor ID:1 Monitor ID:2 Monitor ID:3 TO USE REMOTE CONTROL ID MODE ID Mode - To enter ID Mode press the REMOTE ID SET button and hold down for 2 seconds. Normal Mode - To return to Normal Mode press the REMOTE ID RESET button and hold down for 2 seconds. In order for this feature to work properly, the display must be assigned a Monitor ID number. The Monitor ID number can be assigned under the MULTI DISPLAY menu in the OSD See page 29. Remote does not work Remote does not work Remote works Figure 2 Remote set up to use Remote ID:3 POWER GUIDE DVI VGA RGB/HV OPTION HDMI DVD/HD VIDEO TV PICTURE MODE SIZE AUDIO SOUND INPUT 1 4 7 DISPLAY 2 3 5 6 8 9 0 ENT MENU AUTO SET UP SET + EXIT VOL CH CH RTN + + MUTE STILL ON/OFF CAPTURE PIP ON/OFF INPUT CHANGE REMOTE ID SET RESET MTS SLEEP REMOTE CONTROLLER RU-M111 ID number assigned to display Monitor ID:1 Target ID:5 INFORMATION OSD Press the "DISPLAY" button on the remote to bring up the Information OSD. The Information OSD shows the monitor ID number and other information such as signal type, zoom method, etc. DVI AUDIO:IN1 SIZE:FULL 1024 X 768 48KHz/60Hz English-14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

English-14
REMOTE CONTROL ID
°e remote control included with the display can be used
to control up to 26 individual MultiSync SC monitors using
what is called the REMOTE CONTROL ID mode. °e RE-
MOTE CONTROL ID mode works in conjunction with the
Monitor ID, allowing control of up to 26 individual Multi-
Sync SC monitors. For example: if there are many monitors
being used in the same area, a remote control in normal
mode would send signals to every monitor at the same
time
Figure 1
. Using the remote in REMOTE CONTROL
ID mode will only operate one specific monitor within the
group
Figure 2
.
TO SET REMOTE CONTROL ID:
While holding down the REMOTE ID SET button on the
remote control, use the KEYPAD to input the Monitor ID
(1-26) of the display to be controlled via remote. °e remote
can then be used to operate the monitor having that specific
Monitor ID number.
When 0 is selected or when the remote control is in normal
mode, all monitors will be operated.
TO USE REMOTE CONTROL ID MODE
ID Mode - To enter ID Mode press the REMOTE ID SET
button and hold down for 2 seconds.
Normal Mode - To return to Normal Mode press the
REMOTE ID RESET button and hold down for 2 seconds.
In order for this feature to work properly, the display must be
assigned a Monitor ID number. °e Monitor ID number can
be assigned under the MULTI DISPLAY menu in the OSD
See page 29.
1
2
3
4
5
6
7
8
0
9
+
+
+
Monitor ID:1
Monitor ID:2
Monitor ID:3
Remote does
not work
Remote does
not work
Remote works
Figure 2
Remote set up to
use Remote ID:3
1
2
3
4
5
6
7
8
0
9
+
+
+
Monitor ID:1
Monitor ID:2
Monitor ID:3
Remote works
Remote works
Remote works
Figure 1
Remote in Normal
mode or the REMOTE
ID is set to 0
Remote Control ID Function
Monitor ID:1
Target ID:5
DVI
AUDIO:IN1
SIZE:FULL
1024 X 768
48KHz/60Hz
ID number assigned to display
INFORMATION OSD
Press the “DISPLAY” button
on the remote to bring up
the Information OSD. °e
Information OSD shows the
monitor ID number and other
information such as signal
type, zoom method, etc.
Part Names and Functions
- continued