NEC V552-TM External Control Codes - Page 5

III. Communication specification, Communication Parameter

Page 5 highlights

III. Communication specification 3. Communication Parameter 3.1 RS-232C Remote control (1) Communication system (2) Interface (3) Baud rate (4) Data length (5) Parity (6) Stop bit (7) Communication code Asynchronous RS-232C 9600bps 8bits None 1 bit ASCII 3.2 LAN control (1) Communication system (2) Interface (3) Communication layer (4) IP address (5) Port No. TCP/IP (Internet protocol suite) Ethernet (CSMA/CD) Transport layer (TCP) * Using the payload of TCP segment. (Default) 192.168.0.10 * If you need to change, Please refer "Network settings" on User's manual. 7142 (Fixed) (Note) The monitor will disconnect the connection if no packet data is received for 15 minutes. And the controller (PC) has to re-connect to control the monitor again, after 15 minutes or more. 3.3 Communication timing The controller should wait for a packet interval before next command is sent. The packet interval needs to be longer than 600msec for the LCD monitor. (5/72)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

(5/72)
III. Communication specification
3. Communication Parameter
3.1 RS-232C Remote control
(1) Communication system
Asynchronous
(2) Interface
RS-232C
(3) Baud rate
9600bps
(4) Data length
8bits
(5) Parity
None
(6) Stop bit
1 bit
(7) Communication code
ASCII
3.2 LAN control
(1) Communication system
TCP/IP (Internet protocol suite)
(2) Interface
Ethernet (CSMA/CD)
(3) Communication layer
Transport layer (TCP)
* Using the payload of TCP segment.
(4) IP address
(Default) 192.168.0.10
* If you need to change,
Please refer
Network settings
on User
s manual.
(5) Port No.
7142 (Fixed)
(Note)
The monitor will disconnect the connection if no packet data is received for 15 minutes.
And the controller (PC) has to re-connect to control the monitor again, after 15 minutes or more.
3.3 Communication timing
The controller should wait for a packet interval before next command is sent.
The packet interval needs to be longer than 600msec for the LCD monitor.