NaceCare CVC 370 WV370 / WV470 / 800 Owners Manual - Page 12
Fault Finding, Dry Mode, Wet Mode
View all NaceCare CVC 370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Fault Finding This machine can be used for wet and dry pick up. Dry Mode If the vacuum cleaner stops working switch off and remove the plug from the wall before investigating were the fault lies. If the vacuum cleaner will not pick up any debris from the surface, switch off and remove the plug from the wall, inspect the floor tool, wands and hose for blockages, if no blockages are found, the dust bag may be full if the dust bag is not full the filter may be blocked. Wet Mode If the vacuum cleaner stops working switch off and remove the plug from the wall before investigating were the fault lies. If the vacuum cleaner has a blockage and will not pick up liquid, switch off and remove the plug from the wall, has the float valve operated, this will shut off the suction and the pitch of the vacuum motor will change Remove the power head and empty the liquid out of the container, if the container is empty, check that the floor tool wands and hose are not blocked. After use always inspect the machine for damage. Data CVC 370 WV 370 WV 470 CVC 370 WV 370 WV 470 Motor 1200W 1200W 1200W Capacity Dry 15 Ltrs 15 Ltrs 27 Ltrs AirFlo 40 L/sec 40 L/sec 40 L/sec Capacity Wet 9 Ltrs 9 Ltrs 20 Ltrs Suction 2500 mm 2500 mm 2500 mm Size 355x355x510 355x355x510 355x355x710 Cleaning Range 28.8m 28.8m 28.8m Weight 7.1 Kgs 7.1 Kgs 9.6 Kgs Class II Sound Pressure 73-77 dB (IEC 60704-2-1) Uncertianty: 0.2 dB (A)