Netgear GSM7328SO GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide
Netgear GSM7328SO Manual
UPC - 606449080162
View all Netgear GSM7328SO manuals
Add to My Manuals
Save this manual to your list of manuals |
Netgear GSM7328SO manual content summary:
- Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 1
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 202-10255-01 February 2007 - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 2
be subject to certain restrictions. Please refer to the notes in the operating instructions. It is hereby certified that the NETGEAR ProSafe™ 48-Port 10/100/1000 L3 managed Stackable Switch with 4 10 Gigabit I/O Slots GSM7352S has been suppressed in accordance with the conditions set out in the BMPT - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 3
, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, This is to certify that the NETGEAR ProSafe™ 48-Port 10/100/1000 L3 managed Stackable Switch with 4 10 Gigabit I/ O Slots GSM7352S is shielded against the generation of - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 4
Customer Support Refer to the Support Information Card that shipped with your Managed Stackable Layer 3 Fast Ethernet Switch. World Wide Web NETGEAR 10/100/1000 L3 managed Stackable Switch with 4 10 Gigabit I/O Slots GSM7352S • ProSafe™ 24 Fiber SFP Gigabit Layer 3 managed Stackable Switch with 4 - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 5
1-2 How to Print this Manual 1-3 Revision History ...1-4 Chapter 2 Introduction GSM7328S Front Panel and LEDs 2-1 GSM7328S Rear Panel 2-4 GSM7352S Front Panel and LEDs 2-4 GSM7352S Rear Panel 2-6 GSM7328FS Front Panel and LEDs 2-7 GSM7328FS Rear Panel 2-9 Safety Instructions ...2-10 Chapter - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 6
Connecting Equipment to the Switch 3-10 RJ-45 Ports ...3-10 Connecting a Console to the Switch 3-11 Chapter 4 Troubleshooting Troubleshooting Chart 4-1 Additional Troubleshooting Suggestions 4-2 Appendix A Technical Specifications Appendix B Default Configuration Settings vi v1.0, February 2007 - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 7
This Manual The Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide describes installation and basic troubleshoting for the NETGEAR® GSM7328S and GSM7352S switches. Audience, Conventions, Formats, and Scope This information in this guide is intended - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 8
GSM7352S • ProSafe™ 24 Fiber SFP Gigabit Layer 3 managed Stackable Switch with 4 10-Gigabit Slots GSM7328FS February 2007 Note: Product updates are available on the NETGEAR, Inc. Web site at http://kbserver.netgear.com/downloads_support.asp. How to Use This Manual The HTML version of this manual - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 9
of any page. • Click the Complete PDF Manual link at the top left of any page in the manual. The PDF version of the complete manual opens in a browser window. • Click the print icon in the upper left of your browser window. Tip: If your printer supports printing two pages on a single sheet of - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 10
Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Revision History Part Number Version Publication Date Description 201-10813-01 1.0 202-10255-01 1.0 March 2006 February 2007 Document Created. Added description of GSM7328FS switch. 1-4 About This Manual v1.0, February 2007 - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 11
increase productivity. This guide describes hardware installation and basic troubleshooting for the following NETGEAR switches: • ProSafe™ . The module bays support any combination of either the ProSafe 24-Gigabit Stackable Module (AX742) or the ProSafe 10-Gigabit Ethernet XFP Adapter (AX741). See " - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 12
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal1 LEDs RST RJ-45 jacks (reset button) Copper/fiber combo ports Stacking/XFP module bays Figure 2-1 The following table describes the - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 13
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Table 2-1. LED Descriptions for GSM7328S (continued) LED Description M1, M2, M3, M4 High-Speed I/O Modules (1 LED per module) XFP Module present or Stacking Adapter present and ACT LED: XFP Module present LED / - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 14
supplied power cord. The module bays support any combination of either the ProSafe 10-Gigabit Ethernet XFP Adapter (AX741) or the ProSafe 24 Redundant power supply connector Console GSM7352S Front Panel and LEDs The figure below shows the front panel of the GSM7352S. The front panel contains LEDs - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 15
and GSM7328FS Hardware Instal- The table below describes the GSM7352S LEDs on the front of the switch. Table 2-2. GSM7352S LED Description LED Description ID This is the stack member ID (1-8) that the software assigns to the switch. Master • Green: The switch is a master unit - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 16
48 media is changed to copper, the SFP LEDs change to OFF status. GSM7352S Rear Panel The rear panel has four module bays, a redundant power supply connector supplied power cord. The module bays support any combination of either the ProSafe 10-Gigabit Ethernet XFP Adapter (AX741) or the ProSafe 24- - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 17
RJ-45 jacks, copper/fiber combo ports, and two module bays. The module bays support any combination of either the ProSafe 24-Gigabit Stackable Module (AX742) or the ProSafe 10-Gigabit Ethernet XFP Adapter (AX741). See "High-Speed I/O Module Bays" in Chapter 3. LEDs RST (reset button) Copper/fiber - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 18
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Table 2-3. LED Descriptions for GSM7328FS LED Description Power /Status LED • Solid Green: Power is supplied to the switch and it is - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 19
GSM7352S and GSM7328FS Hardware Instal- Table 2-3. LED Descriptions for GSM7328FS (continued) LED 4-10GbE interface Module One LED /module RPS LED Description XFP Module Present or Stacking Adapter Off: NETGEAR RPS Bank support any combination of either the ProSafe 10-Gigabit Ethernet XFP Adapter - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 20
Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Safety Instructions Use the following safety guidelines If the system gets wet, see the appropriate section in your troubleshooting guide or contact your trained service provider. • Do not push any objects into the openings of your - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 21
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- • To help avoid damaging power cables are equipped with three-prong plugs to help ensure proper grounding. Do not use adapter plugs or remove the grounding prong from a cable. If you must use an extension cable - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 22
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- 2-12 v1.0, February 2007 Introduction - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 23
GSM7328S, GSM7352S, and preinstalled software • Power adapter cord • Rubber NETGEAR 7000 Series Managed Switch Administration Guide, the NETGEAR Installation Guide for the 7000 Series Stackable Managed Switch, and this Hardware Installation Guide • Warranty and Support Card • Installation Guide - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 24
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Protecting Against Electrostatic Discharge Warning: Static electricity can harm delicate components inside your system. To prevent static damage, discharge static electricity - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 25
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- 4. Make sure that all items are present. See "Package Contents" on page 3-1. Note: If any item is found missing or damaged, contact your local NETGEAR reseller for replacement. 5. Inspect the products and - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 26
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Select a Location The switch can be mounted in a standard 19-inch (48.26-centimeter) rack, wallmounted, or left freestanding (placed on a - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 27
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Install the Switch You can install the switch on a flat surface or in a standard 19-inch rack. Installing the Switch on a - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 28
3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal these steps to apply AC power. 1. Connect one end of the AC power adapter cable to the rear of the switch, and the other end to a grounded troubleshooting, see Chapter 4, "Troubleshooting". 3-6 Hardware Installation v1.0, February 2007 - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 29
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- High-Speed I/O the remaining module bays for 10-Gigabit Ethernet XFP Adapters (AX741). The modules and adapters are sold separately. Note: If you want to support more than two 10-Gigabit Ethernet connections, any - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 30
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- 2. To install additional Gigabit Ethernet modules, repeat step 1. High-Speed I/O Module Installation The High-Speed I/O Module Bays support ProSafe 10-Gigabit Ethernet XFP Adapter (AX741) or ProSafe 24-Gigabit - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 31
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Stacking You can connect up to eight switches to form a stack with a single management IP address. The switches automatically select a master unit. Once the master is selected, you can use its console to manage all - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 32
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Connecting a Redundant Power Supply Each switch has a redundant power supply (RPS) connector at the rear of the switch next to the - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 33
Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Connecting a Console to the Switch After you install the switch and apply power, you can connect to it with a terminal or workstation. You can use the Command Line Interface (CLI) to identify the IP address. If you are stacking - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 34
GSM7352S and GSM7328FS Hardware Instal- After you connect a console to the switch, you will need to configure the switch. The following documents are provided for this purpose: • Quick Installation Guide CD. • NETGEAR 7000 Series Managed Switch Administration Guide: Describes configuration tasks - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 35
lists symptoms, causes, and solutions of possible problems. Table 4-1. Troubleshooting Chart Problem Power LED is off. Link LED is off and comply with Ethernet specifications. See Appendix A. Check for a defective adapter card, cable, or port by testing it in an alternate environment where - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 36
4-1 do not resolve your problem, refer to the troubleshooting suggestions in this section. • Network Adapter Cards Make sure that the network adapter cards installed in the PCs are in working condition and the software driver has been installed. • Configuration: If problems occur after you change - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 37
IEEE Network Protocol and Standards compatibility Switch management GSM7328S GSM7352S 802.3 10BASE-T 802.3u 100BASE-TX 802.3z .3ab 1000BASE-T 802.3ae 10000BASE-LR 802.3ae 10000BASE-SR 802.3x flow control • Port mirroring support • SNMP v1, v2c, v3 • RFC1757 RMON 1 groups 1, 2, 3, and 9 • RFC1213 - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 38
GSM7352S GSM7328FS Layer 2 Services • 802.1Q Static VLAN (Up to 4k) • 802.1p Class of Service Aggregation (LACP) • IGMP v1, v2 Snooping Support Layer 3 Services • VLAN routing • Port routing • RIP Address 8K MAC addresses per system database size 10/100/1000 8MB embedded memory for Max support - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 39
(continued) Feature GSM7328S GSM7352S GSM7328FS Performance • Forwarding modes: Store-and-forward • Network latency: Less than 80 microseconds for 64-byte frames in store-and-forward mode for 10 Mbps to 100 Mbps transmission • Addressing: 48-bit MAC address • Acoustic noise: (ANSI - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 40
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- A-4 Technical Specifications v1.0, February 2007 - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 41
This appendix provides the default settings for the NETGEAR Model GSM7328S, GSM7352S, and GSM7328FS switches. Table B-1. Default Configuration VLAN All ports belong to default VLAN (VLAN 1) as untagged ports IP multicast filtering Disabled Spanning Tree Protocol Enabled (IEEE 802.1s) Admin - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 42
Managed Stackable Layer 3 Switches GSM7328S, GSM7352S and GSM7328FS Hardware Instal- Table B-1. Default Configuration Settings (continued) Features IP routing RIP MAC address aging OSPF SNMP community DHCP Server VLAN Ingress filtering IP multicast filtering VRRP Default Setting Disabled Disabled - Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 43
- Netgear GSM7328SO | GSM7328S, GSM7352S and GSM7328FS Hardware Installation Guide - Page 44
NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA February 2007
202-10255-01
February 2007
NETGEAR
, Inc.
4500 Great America Parkway
Santa Clara, CA 95054 USA
Managed Stackable Layer 3
Switches GSM7328S,
GSM7352S and
GSM7328FS Hardware
Installation Guide