Netgear RP334 Installation Guide - Page 2

c. Europe If your service provider uses Alcatel's ANT ADSL Network Termination with PPTP - manual

Page 2 highlights

4 LAUNCH YOUR BROWSER This section describes the steps required to configure your router using a web browser such as Microsoft Internet Explorer or Netscape Navigator. This will provide a basic configuration for Internet access. 1. From any PC on your local network, launch your web browser. 2. In the Address box of your browser, type http://192.168.0.1 and press ENTER. 3. A log-in box will appear. For Name, enter admin. For Password, enter 1234. If your router's configuration password has been previously changed from the factory default of 1234, enter the current password. 4. At the opening screen, select WIZARD SETUP. 5. In the first Wizard screen, enter your account's Host Name and Domain Name. 6. Click Next to go to the ISP Parameters screen. This screen determines whether a login program will be run. a. If your service provider does not require a login program, leave Encapsulation as Ethernet and proceed to Step 7. b. If your service provider uses PPPoE, select Encapsulation as PPPoE, and enter these additional parameters: - If your connection supports multiple ISPs, enter the Service Name of the one you use. Otherwise leave Service Name blank. - Enter the user name and password provided by your ISP. These fields are case sensitive. - If you wish to change the login timeout, enter a new value in seconds. Proceed to Step 7. c. (Europe) If your service provider uses Alcatel's ANT (ADSL Network Termination) with PPTP as a login method, select Encapsulation as PPTP, and enter these additional paramenter: - Enter the PPTP login user name and password provided by your ISP. - If you wish to change the login timeout, enter a new value in seconds. - If provided by your ISP, enter your PPTP IP Address and the Server IP Address of their PPTP Server. - If provided by your ISP, enter the Connection ID/Name for yoour service. Otherwise leaves this field blank. Proceed to Step 7. c. If your service provider is RoadRunner AND you are required to run a RoadRunner login program, leave Encapsulation as Ethernet and select Service Type as either RR-Manager or RR-Toshiba. Enter these additional parameters:. - If your cable modem is Toshiba, select RR-Toshiba. Otherwise select RR-Manager. - Enter the user name and password provided by your ISP. These fields are case sensitive. - If RoadRunner provided an authentication server address, enter it as Login Server IP address. Otherwise, leave this field as 0.0.0.0. Not all RoadRunner regions require a login program. If your region does not require a login, leave Service Type as Standard. 7. Click on Next to go to the final Wizard screen shown below. a. WAN IP Address Assignment: Unless your ISP has assigned a fixed permanent IP address for your use, select "Get automatically from ISP". Otherwise, enter your IP Address, Subnet Mask, and the IP Address of your ISP's gateway router. b. DNS Server Address Assignment: If you know that your ISP does not automatically transmit DNS addresses to the router during login, select "Use this server" and enter the IP address of the ISP's DNS server. A DNS server is a host on the Internet that translates Internet names (such as www addresses) to numeric IP addresses. Typically your ISP transfers the IP addresses of one or two DNS servers to your router during login. If the ISP does not transfer an address, you must obtain it from the ISP and enter it manually here. If you enter an address here, you should reboot your PCs after configuring the router. c. WAN MAC address: If your ISP allows access by only one specific PC's Ethernet MAC address, select "Spoof this PC's MAC address" and enter the IP address of that PC. - For convenience, the IP address of the PC you are now using should already appear. If this is not the PC whose MAC address is to be used, enter that PC's IP address. - Some ISPs will register the Ethernet MAC address of the network interface card in your PC when your account is first opened. They will then only accept traffic from the MAC address of that PC. This feature allows your router to masquerade as that PC by using its MAC address. 8. Click Finish. 5- TEST YOUR CONNECTION Accessing the Internet Click the NETGEAR Web site address to test your Internet connection. When your router and PCs are configured correctly, your router automatically accesses the Internet when one of your LAN devices requires access. It is not necessary to run a dialer application, such as Dial-Up Networking or RoadRunner Login, to connect, log in, or disconnect. These functions are performed by the router as needed. To access the Internet: 1. From the PC connected to your router, launch a browser such as Microsoft Internet Explorer or Netscape Navigator. You should see the Internet LED blink, indicating communication to the ISP. The browser should begin to display a Web page. If you have trouble accessing the Internet, refer to the "Troubleshooting" section of this guide. Configuring for Content Filtering and Reporting After you have successfully configured your router for Internet access, you can configure it for content filtering and reporting by following these steps: 1. Re-enter the browser configuration by accessing http://192.168.0.1, logging in if necessary. 2. Click Advanced, then Security. To receive logs and alerts by e-mail: a. Select the e-mail tab and enter your e-mail account's Outgoing (SMTP) Mail Server name. b. Enter the e-mail address to which the router should send logs and alerts. c. Select when you would like to receive logs and alerts. d. Click Apply. 3. To specify blocking of keywords in Web site names, or blocking of Internet domains: a. Click the Keywords tab. b. Click the Enable Keyword Blocking checkbox. c. Enter the keywords or domain names that you wish to block access to. For each entry, type the entry and click Add Keyword. d. Click Apply. For more information on configuring the content filtering and reporting features of your router, refer to the Reference Guide for the Model RP334 Cable/DSL Phoneline Safe Router in the enclosed Model RP334 Resource CD-ROM. 6 ENJOY BEING CONNECTED! Features Your RP334 Phoneline Router provides you with the following key features: • Customized Web content filtering capability, based on time-of-day, web address or web address keywords • E-mailed instant alerts and notification of router activity • Shared, high-speed Internet access using one Internet address • Provides VPN pass-through for an extra layer of security for shared resources • Hardware-based Network Address Translation (NAT) • Integrated 3-port, 10/100 Mbps switch • Visual monitoring of router status and activity • Compatibility with Windows, Macintosh, and Linux operating systems • Five-year warranty on unit, one-year warranty on power supply • Free technical support seven days a week, twenty-four hours a day PRODUCT ILLUSTRATIONS Front Panel The front panel of the Model RP334 router (Figure 2-1) contains status LEDs. Phoneline Router PHONELINE RP334 Power LED T est LED Internet Ethernet LEDs Local Ethernet LEDs Phoneline LED LEDs You can use some of the LEDs to verify connections. Table 2-1 lists and describes each LED on the front panel of the Model RP334 router. These LEDs are green when lit. Label PWR (Power) TEST Internet LNK ACT (Activity) Activity On Off On Off Blinking Description Power is supplied to the router. Power is not supplied to the router. The system is not ready or has failed to start up. The system is ready and running. The system is initializing. On Blinking The Internet port has detected a link with an attached device. Data is being transmitted or received by the Internet port. Phoneline LNK ACT (Activity) Local LNK/ACT (Link/Activity) 100 (100 Mbps) On Blinking The Phoneline port has detected a link with an attached device. Data is being transmitted or received by the Phoneline port. On Blinking On Off The Local Ethernet port has etected a link with an attached device. Data is being transmitted or received by the Local Ethernet port. The port is operating at 100Mbps. The port is operating at 10Mbps. Rear Panel The rear panel of the Model RP334 router (Figure 2-1) contains port connections and a power switch. PHONELINE To Wall To Phone LOCAL 10/100 3 2 1 INTERNET Local Phoneline Port Default Local Internet Reset Ethernet Ethernet Button Ports Port Power Switch Power Connector TROUBLESHOOTING Symptom Cause Solu tion PWR and other LEDs are not lit when you switch on your router No power is received to the router Make sure the power cord is properly connected to the router. Make sure you are using the correct NETGEAR power adapter supplied with your router. Make sure the power adapter is properly connected to a functioning power outlet. After you apply power to the router, the TEST LED should turn off after approximately 90 seconds. If the TEST LED does not turn off, switch off the router; then switch it on again. LOCAL or INTERNET Hardware connection LINK/ACT LEDs do not problem light when connected to your PCs or modem Make sure the Ethernet cable connections are secure at the router and at the device to which you are connected. Make sure the connected device is powered on. Be sure you are using the correct cable: • If you are connecting one of the router's LAN ports to a PC, use a standard straight-through Ethernet cable like the one provided with your router. • When connecting the router's Internet port to a cable or DSL modem, use the cable supplied with your modem, not the one supplied with your router. Router is unable to load any Web pages from the Internet Your PC may not recognize any DNS server addresses A DNS server is a host on the Internet that translates Internet names (such as WWW addresses) to numeric IP addresses. Typically your ISP will provide the addresses of one or two DNS servers for your use. If you entered a DNS address into your router during the configuration, reboot your PC and verify the DNS address as described in "Verifying TCP/IP Properties." Alternatively, you may manually configure your PC with DNS addresses as explained in "Configuring TCP/IP" in the Reference Guide for the Model RP334 Cable/DSLPhoneline Router. Your PC may not have If your PC obtains its information from the router by the router configured DHCP, reboot the PC and verify the gateway address as as its TCP/IP gateway described below in "Verifying TCP/IP Properties." Phoneline Link LED is not ON Your router may have been unable to obtain a WAN IP address from the ISP Verify that the router has a WAN IP address by following these steps: 1. Launch a browser and selct an external site. 2. Return to the Main Menu of the router's configuration (http://192.168.0.1). 3. Under the Advanced heading, click on Maintenance. 4. Check that an IP address is shown for the WAN Port. If 0.0.0.0 is shown, reconfirm the configuration information from your ISP. Port connection not functioning Make sure that the telephone cable is connected between the RP334 port labeled "to Wall" and the telephone wall jeck. Phoneline Link LED flashes ON and OFF Telephone or fax connected to the Phoneline port. Make sure there is at least one other PC or Bridge ON and connected to the RP334. Make sure the telephone cable attached to the telephone or fax machine is at least 5 feet long. Verifying TCP/IP Properties (Windows) After the Windows PC is configured and has rebooted, you can check the TCP/IP configuration using the Windows utility winipcfg.exe (for Windows NT systems, use ipconfig.exe). To check your PC's TCP/IP configuration: 1. On the Windows taskbar, click the Start button, and then click Run. The Run window opens. 2. Type winipcfg, and then click OK. The IP Configuration window opens. 3. Select your Ethernet adapter. The window is updated to show your settings, which should match the values below if you are using the default TCP/IP settings that NETGEAR recommends: • The IP Address is between 192.168.0.2 and 192.168.0.32 • The Subnet Mask is 255.255.255.0 • The Default Gateway is 192.168.0.1 4. Click More Info, and verify that the "DNS Servers" box displays 192.168.0.1. Verifying TCP/IP Properties (Macintosh) After the Macintosh has rebooted, check the TCP/IP properties: 1. From the Apple menu, select the TCP/IP Control Panel. 2. If you are using the default TCP/IP settings that NETGEAR recommends, your setting should match these: • The IP Address is between 192.168.0.2 and 192.168.0.32 • The Subnet Mask is 255.255.255.0 • The Router address is 192.168.0.1 • Name server address is 192.168.0.1 © 2001 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of NETGEAR, Inc. Other brand and product names are trademarks or registered trademarks of their respective holders. Information is subject to change without notice. Statement of Conditions In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products described in this document without notice. NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein. Certificate of the Manufacturer/Importer It is hereby certified that the NETGEAR Model RP334 Cable/DSL Phoneline Router has been suppressed in accordance with the conditions set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/1992. The operation of some equipment (for example, test transmitters) in accordance with the regulations may, however, be subject to certain restrictions. Please refer to the notes in the operating instructions. Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the market and has been granted the right to test the series for compliance with the regulations. Bestätigung des Herstellers/Importeurs Es wird hiermit bestätigt, daß das Model RP334 Cable/DSL Phoneline Router gemäß der im BMPT-AmtsblVfg 243/1991 und Vfg 46/1992 aufgeführten Bestimmungen entstört ist. Das vorschriftsmäßige Betreiben einiger Geräte (z.B. Testsender) kann jedoch gewissen Beschränkungen unterliegen. Lesen Sie dazu bitte die Anmerkungen in der Betriebsanleitung. Das Bundesamt für Zulassungen in der Telekommunikation wurde davon unterrichtet, daß dieses Gerät auf den Markt gebracht wurde und es ist berechtigt, die Serie auf die Erfüllung der Vorschriften hin zu überprüfen. Voluntary Control Council for Interference (VCCI) Statement This equipment is in the second category (information equipment to be used in residential areas) and conforms to the standards set by the Voluntary Control Council for Interference by Data Processing Equipment and Electronic Office Machines that are aimed at preventing radio interference in residential areas. EN 55 022 Declaration of Conformance This is to certify that the NETGEAR Model RP334 Cable/DSL Phoneline Router is shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class B (CISPR 22). Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. FCC Part 68 Compliance Statement This equipment complies with Part 68 of FCC Rules. All direct connections to telephone network lines must be made using standard plugs and jacks compliant with FCC Part 68. Canadian Department of Communications Radio Interference Regulations This digital apparatus (NETGEAR Model RP334 Cable/DSL Phoneline Router) does not exceed the Class B limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications. Règlement sur le brouillage radioélectrique du ministère des Communications Cet appareil numérique (NETGEAR Model RP334 Cable/DSL Phoneline Router) respecte les limites de bruits radioélectriques visant les appareils numériques de classe B prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada.

  • 1
  • 2

Configuring for Content Filtering and Reporting
After you have successfully configured your router for Internet access,you can configure it for content fil-
tering and reporting by following these steps:
1. Re-enter the browser configuration by accessing http://192.168.0.1, logging in if necessary.
2. Click Advanced, then Security. To receive logs and alerts by e-mail:
a. Select the e-mail tab and enter your e-mail account’s Outgoing (SMTP) Mail Server name.
b. Enter the e-mail address to which the router should send logs and alerts.
c. Select when you would like to receive logs and alerts.
d.
Click Apply.
3. To specify blocking of keywords in Web site names, or blocking of Internet domains:
a. Click the Keywords tab.
b. Click the Enable Keyword Blocking checkbox.
c. Enter the keywords or domain names that you wish to block access to.
For each entry, type the
entry and click Add Keyword.
d.
Click Apply.
For more information on configuring the content filtering and reporting features of your router,refer to
the
Reference Guide for the Model RP334 Cable/DSL Phoneline Safe Router
in the enclosed
Model RP334
Resource
CD-ROM.
Features
Your RP334 Phoneline Router provides you with the following key features:
Customized Web content filtering capability, based on time-of-day, web address or web address keywords
E-mailed instant alerts and notification of router activity
Shared, high-speed Internet access using one Internet address
• Hard
Provides VPN pass-through for an extra layer of security for shared resources
ware-based Network Address Translation (NAT)
Integrated 3-port, 10/100 Mbps switch
Visual monitoring of router status and activity
Compatibility with Windows, Macintosh, and Linux operating systems
Five-year warranty on unit, one-year warranty on power supply
Free technical support seven days a week, twenty-four hours a day
Front Panel
The front panel of the Model RP334 router (Figure 2-1) contains status LEDs.
LEDs
You can use some of the LEDs to verify connections. Table 2-1 lists and describes each LED on the
front panel of the Model RP334 router. These LEDs are green when lit.
Label
Activity
Description
PWR (Power)
On
Off
Power is supplied to the router.
TEST
On
The system is ready and running.
Blinking
The system is initializing.
Internet
Phoneline
LNK
On
The Internet port has detected a link with an attached device.
ACT (Activity)
Blinking
Data is being transmitted or received by the Internet port.
LNK
ACT (Activity)
On
The Phoneline port has detected a link with an attached device.
Data is being transmitted or received by the Phoneline port.
Rear Panel
The rear panel of the Model RP334 router (Figure 2-1) contains port connections and a power switch.
This section describes the steps required to configure your router using a web browser such as Microsoft
Internet Explorer or Netscape Navigator.This will provide a basic configuration for Internet access.
1. From any PC on your local network, launch your web browser.
2. In the Address box of your browser, type http://192.168.0.1 and press ENTER.
3. A log-in box will appear. For Name, enter admin. For Password, enter 1234.
If your router’s configuration password has been previously changed from the factory default
of 1234, enter the current password.
4. At the opening screen,select WIZARD SETUP.
5. In the first Wizard screen, enter your account’s Host Name and Domain Name.
6. Click Next to go to the ISP Parameters screen.
This screen determines whether a login program will be run.
a. If your service provider does not require a login program, leave Encapsulation as Ethernet
and proceed to Step 7.
b. If your service provider uses PPPoE, select Encapsulation as PPPoE, and enter these
additional parameters:
If your connection supports multiple ISPs, enter the Service Name of the one you use.
Otherwise leave Service Name blank.
Enter the user name and password provided by your ISP.These fields are case sensitive.
If you wish to change the login timeout, enter a new value in seconds.
Proceed to Step 7.
c. If your service provider is RoadRunner AND you are required to run a RoadRunner login
program, leave Encapsulation as Ethernet and select Service Type as either RR-Manager or
RR-Toshiba. Enter these additional parameters:.
If your cable modem is Toshiba, select RR-Toshiba. Otherwise select RR-Manager.
Enter the user name and password provided by your ISP.These fields are case sensitive.
If RoadRunner provided an authentication server address,enter it as Login Server
IP address. Otherwise, leave this field as 0.0.0.0.
Not all RoadRunner regions require a login program. If your region does not require a login, leave
Service Type as Standard.
7. Click on Next to go to the final Wizard screen shown below.
a. WAN IP Address Assignment: Unless your ISP has assigned a fixed permanent IP address for
your use, select “Get automatically from ISP”. Otherwise, enter your IP Address, Subnet Mask,
and the IP Address of your ISP’s gateway router.
b. DNS Server Address Assignment: If you know that your ISP does not automatically transmit
DNS addresses to the router during login, select “Use this server” and enter the IP address of
the ISP’s DNS server.
A DNS server is a host on the Internet that translates Internet names (such as www addresses) to
numeric IP addresses.Typically your ISP transfers the IP addresses of one or two DNS servers to
your router during login. If the ISP does not transfer an address, you must obtain it from the ISP
and enter it manually here. If you enter an address here, you should reboot your PCs after configur-
ing the router.
c. WAN MAC address: If your ISP allows access by only one specific PC’s Ethernet MAC address,
select “Spoof this PC’s MAC address” and enter the IP address of that PC.
For convenience, the IP address of the PC you are now using should already appear. If this
is not the PC whose MAC address is to be used, enter that PC’s IP address.
Some ISPs will register the Ethernet MAC address of the network interface card in your
PC when your account is first opened.They will then only accept traffic from the MAC
address of that PC.This feature allows your router to masquerade as that PC by using its
MAC address.
8. Click Finish.
Accessing the Internet
Click the NETGEAR Web site address to test your Internet connection.
When your router and PCs are configured correctly,your router automatically accesses the Internet when
one of your LAN devices requires access. It is not necessary to run a dialer application, such as Dial-Up
Networking or RoadRunner Login, to connect, log in, or disconnect.These functions are performed by the
router as needed.
To access the Internet:
1. From the PC connected to your router, launch a browser such as Microsoft Internet Explorer or
Netscape Navigator.
You should see the Internet LED blink,indicating communication to the ISP.The browser should begin to
display a Web page.
If you have trouble accessing the Internet, refer to the “Troubleshooting” section of this guide.
Symptom
Cause
Solu
tion
PWR and other LEDs
No power is received
Make sure the power cord is properly connected to
are not lit when you
to the router
the router.
switch on your router
Make sure you are using the correct NETGEAR power
adapter supplied with your router.
Make sure the power adapter is properly connected to
a functioning power outlet.
After you apply power to the router,the TEST LED
should turn off after approximately 90 seconds.
If the TEST LED does not turn off, switch off the
router; then switch it on again.
LOCAL or INTERNET
Hardware connection
Make sure the Ethernet cable connections are secure at
LINK/ACT LEDs do not
problem
the router and at the device to which you are connected.
light when connected to
Make sure the connected device is powered on.
your PCs or modem
Be sure you are using the correct cable:
• If you are connecting one of the router's LAN
ports to a PC, use a standard straight-through
Ethernet cable like the one provided with your router.
• When connecting the router’s Internet port to a
cable or DSL modem, use the cable supplied with
your modem,not the one supplied with your router.
Router is unable to
Your PC may not
A DNS server is a host on the Internet that translates
load any Web pages
recognize any DNS
Internet names (such as WWW addresses) to numeric IP
from the Internet
server addresses
addresses.Typically your ISP will provide the addresses
of one or two DNS servers for your use. If you entered a
DNS address into your router during the configuration,
reboot your PC and verify the DNS address as described
in “Verifying TCP/IP Properties.” Alternatively, you may
manually configure your PC with DNS addresses as
explained in “Configuring TCP/IP” in the
Reference
Guide for the Model RP334 Cable/DSLPhoneline Router
.
Your PC may not have
If your PC obtains its information from the router by
the router configured
DHCP,reboot the PC and verify the gateway address as
as its TCP/IP gateway
described below in “Verifying TCP/IP Properties.”
Your router may have
Verify that the router has a WAN IP address by follow-
been unable to obtain
ing these steps:
a WAN IP address
1.
Launch a browser and selct an external site.
from the ISP
2.
Return to the Main Menu of the router’s
configuration (http://192.168.0.1).
3.
Under the Advanced heading, click on Maintenance.
4.
Check that an IP address is shown for the WAN
Port. If 0.0.0.0 is shown, reconfirm the configuration
information from your ISP.
Verifying TCP/IP Properties (Windows)
After the Windows PC is configured and has rebooted,you can check the TCP/IP configuration using the
Windows utility winipcfg.exe (for Windows NT systems,use ipconfig.exe).
To check your PC’s TCP/IP configuration:
1. On the Windows taskbar, click the Start button, and then click Run.The Run window opens.
2. Type
winipcfg
, and then click OK. The IP Configuration window opens.
3. Select your Ethernet adapter.The window is updated to show your settings, which should match the
values below if you are using the default TCP/IP settings that NETGEAR recommends:
The IP Address is between 192.168.0.2 and 192.168.0.32
The Subnet Mask is 255.255.255.0
The Default Gateway is 192.168.0.1
4. Click More Info, and verify that the “DNS Servers” box displays 192.168.0.1.
Verifying TCP/IP Properties (Macintosh)
After the Macintosh has rebooted, check the TCP/IP properties:
1. From the Apple menu, select the TCP/IP Control Panel.
2. If you are using the default TCP/IP settings that NETGEAR recommends, your setting should
match these:
The IP Address is between 192.168.0.2 and 192.168.0.32
The Subnet Mask is 255.255.255.0
The Router address is 192.168.0.1
Name server address is 192.168.0.1
© 2001 by NETGEAR, Inc. All rights reserved.
Trademarks
NETGEAR
is a trademark of NETGEAR, Inc. Other brand and product names are trademarks or
registered trademarks of their respective holders. Information is subject to change without notice.
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the
right to make changes to the products described in this document without notice.
NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or
circuit layout(s) described herein.
Certificate of the Manufacturer/Importer
It is hereby certified that the NETGEAR Model RP334 Cable/DSL Phoneline Router has been suppressed
in accordance with the conditions set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/1992.The opera-
tion of some equipment (for example, test transmitters) in accordance with the regulations may, however, be
subject to certain restrictions. Please refer to the notes in the operating instructions.
Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the
market and has been granted the right to test the series for compliance with the regulations.
Bestätigung des Herstellers/Importeurs
Es wird hiermit bestätigt, daß das Model RP334 Cable/DSL Phoneline Router gemäß der im
BMPT-AmtsblVfg 243/1991 und Vfg 46/1992 aufgeführten Bestimmungen entstört ist. Das
vorschriftsmäßige Betreiben einiger Geräte (z.B.Testsender) kann jedoch gewissen Beschränkungen
unterliegen. Lesen Sie dazu bitte die Anmerkungen in der Betriebsanleitung.
Das Bundesamt für Zulassungen in der Telekommunikation wurde davon unterrichtet,daß dieses Gerät auf
den Markt gebracht wurde und es ist berechtigt,die Serie auf die Erfüllung der Vorschriften hin
zu überprüfen.
Voluntary Control Council for Interference (VCCI) Statement
This equipment is in the second category (information equipment to be used in residential areas) and con-
forms to the standards set by the Voluntary Control Council for Interference by Data Processing Equipment
and Electronic Office Machines that are aimed at preventing radio interference in residential areas.
EN 55 022 Declaration of Conformance
This is to certify that the NETGEAR Model RP334 Cable/DSL Phoneline Router is shielded against the
generation of radio interference in accordance with the application of Council Directive 89/336/EEC,
Article 4a. Conformity is declared by the application of EN 55 022 Class B (CISPR 22).
Federal Communications Commission (FCC) Compliance Notice:Radio Frequency Notice
This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant
to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful
interference in a residential installation.This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on,the user is encouraged to try to correct the interference
by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
Canadian Department of Communications Radio Interference Regulations
T
FCC Part 68 Compliance Statement
This equipment complies with Part 68 of FCC Rules. All direct connections to telephone network lines
must be made using standard plugs and jacks compliant with FCC Part 68.
his digital apparatus (NETGEAR Model RP334 Cable/DSL Phoneline Router) does not exceed the Class
B limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of
the Canadian Department of Communications.
Règlement sur le brouillage radioélectrique du ministère des Communications
Cet appareil numérique (NETGEAR Model RP334 Cable/DSL Phoneline Router) respecte les
limites de bruits radioélectriques visant les appareils numériques de classe B prescrites dans le Règlement
sur le brouillage radioélectrique du ministère des Communications du Canada.
6
-
TEST YOUR CONNECTION
ENJOY BEING CONNECTED!
5
PRODUCT ILLUSTRATIONS
TROUBLESHOOTING
4
LAUNCH YOUR BROWSER
The system is not ready or has failed to start up.
Off
Blinking
Local
LNK/ACT
(Link/Activity)
100 (100 Mbps)
On
The Local Ethernet port has etected a link with an attached device.
Data is being transmitted or received by the Local Ethernet port.
The port is operating at 100Mbps.
The port is operating at 10Mbps.
Blinking
On
Off
c. (Europe) If your service provider uses Alcatel’s ANT (ADSL Network Termination) with PPTP
as a login method, select Encapsulation as PPTP, and enter these additional paramenter:
– Enter the PPTP login user name and password provided by your ISP.
– If you wish to change the login timeout, enter a new value in seconds.
– If provided by your ISP, enter your PPTP IP Address and the Server IP Address of their PPTP Server.
– If provided by your ISP, enter the Connection ID/Name for yoour service. Otherwise leaves this field blank.
Proceed to Step 7.
Power is not supplied to the router.
Power LED
T est LED
Internet
Ethernet
LEDs
Local
Ethernet
LEDs
Phoneline LED
RP
334
Phoneline Router
PHONELINE
Power Connector
Power Switch
Internet
Ethernet
Port
Local
Ethernet
Ports
Default
Reset
Button
Local Phoneline Port
LOCAL
INTERNET
3
2
1
10/100
PHONELINE
To Wall
To Phone
Phoneline Link
LED is not ON
Phoneline Link LED
flashes ON and OFF
Port connection
not functioning
Telephone or fax
connected to the
Phoneline port.
Make sure that the telephone cable is connected
between the RP334 port labeled “to Wall” and the
telephone wall jeck.
Make sure there is at least one other PC or Bridge
ON and connected to the RP334.
Make sure the telephone cable attached to the
telephone or fax machine is at least 5 feet long.