Onkyo PCA1120 Owners Manual - Page 1

Onkyo PCA1120 Manual

Page 1 highlights

.0/0108&3".1-*'*&3 *OTUSVDUJPO.BOVBM 'FBUVSFT ɹ˔Y8BUPINT GPSDPNNFSDJBMBOEJOEVTUSJBMVTF ɹ˔-P; PINT )J; 7 DPNQBUJCMF ɹ˔JOQVUBOEMPPQPVU ɹ˔1SFTFU&2 )1'BOE-1'GPSMPVETQFBLFST ɹ˔%ZOBNJD-PVEOFTTGPSDPNGPSUBCMF#(. ɹ˔4FUVQEPOFMPDBMMZGSPNSFBSQBOFM ɹ˔&YQBOEBCMFXJUIPQUJPOBMQPXFSBNQMJpFS1 6SBDLNPVOUBCMF XJUIPQUJPOBM*3, 4/" * 2 9 4 0 3 5 4 7 A* 1BDLBHF$POUFOUT ɹɾ.BJO6OJU ɾ*OTUSVDUJPO.BOVBM 5IJT%PDVNFOU ɹɾ"$1PXFS$PSE ɾ4BGFUZ*OGPSNBUJPO ɹɾQJO&VSPCMPDLT  ɾ8BSSBOUZ$BSE 5IJTQSPEVDUJTJOUFOEFEGPSDPNNFSDJBMQSPGFTTJPOBMVTF *UTIPVMECFJOTUBMMFEPOMZCZBTQFDJBMMZUSBJOFEUFDIOJDJBO 4ZTUFN$POpHVSBUJPO&YBNQMFT 4FFXFCTJUFGPSEFUBJMFEDPOOFDUJPOT ˙&YBNQMF" &YQBOEJOHUIFTZTUFNVTJOHUIF.$" 1$" YTIPXO  BOEBEEJUJPOBMTQFBLFST .$" ̇ *OUIFNBJOTQBDF ɾɹɾɹɾ )J;TQFBLFST 3BUFEUPUBM8PSMFTT 1$" *OUIF7*1BSFB ɾɹɾɹɾ -P;TQFBLFST $PNQPTJUFJNQFEBODFЊPSNPSF 1$" *OUIFUFSSBDFBSFB ɾɹɾɹɾ %SJQQSPPGTQFBLFS )J;8PSMFTT -P;ЊPSNPSF *OUIJTDPOpHVSBUJPOXJUINVMUJQMFSPPNTBOETQFBLFSUZQFT UIF.$"DPOUSPMTUIFPWFSBMMWPMVNFPGUIFTZTUFN XIJMFFBDI 1$"WPMVNFMFWFMDBOCFBEKVTUFEGPSJUTSPPN ˙&YBNQMF# *."(&/054)08/ %SJWJOHBQBTTJWFTVCXPPGFSXJUIUIF1$"   5IF1$"IBTCVJMUJODSPTTPWFSTFUUJOHTGPSUIJTBQQMJDBUJPO ˙&YBNQMF$ &BTZ#(.TZTUFN 1$" ɾɹɾɹɾ -P;TQFBLFST $PNQPTJUFJNQFEBODFЊPSNPSF 4FUVQ4UFQT 4UFQ 1 2 3 4 5 6 7 8 9 10 %*14XJUDIFT 4UFQ AC INLET IR IN SPEAKER OUT 1 2 3 4 5 6 7 8 9 10 RS232 SET UP REMOTE VOL 1 2 3 4 5 6 7 8 9 10 SOUND MODE MODEL NO. PCA1120 Input : 100 -240 V 50 / 60 Hz Class2 Wiring COM 70 V 100 V 2 Ω - 8 Ω L R LINE OUT LINE IN (MONO) (MONO/STEREO) 0QUJPO 4QFBLFST 4UFQ .$"PS &YUFSOBM1MBZFS 4UFQ "$1PXFS 1$" 4QFBLFS&YQBOTJPO 0QUJPO 3FNPUF 7PMVNF$POUSPMMFS 1$"3FBS1BOFM ᶃ ᶈᶉ ᶊ ᶇ AC INLET IR IN SPEAKER OUT 1 2 3 4 5 6 7 8 9 10 RS232 SET UP REMOTE VOL 1 2 3 4 5 6 7 8 9 10 SOUND MODE MODEL NO. PCA1120 Input : 100 -240 V 50 / 60 Hz Class2 Wiring COM 70 V 100 V 2 Ω - 8 Ω ᶄ ᶅ L R LINE OUT LINE IN (MONO) (MONO/STEREO) ᶆ ᶃ"$*OMFU 77)[  ˰TFF4UFQ ᶄ41&",&30655FSNJOBMTʢ &VSPCMPDLʣ ɹɹ/05& ɹɹɹ*UJTJNQPSUBOUUPSFBEʠ 4UFQ$POOFDUJOH4QFBLFSTʡCFGPSFBUUFNQUJOHUPVTFUIJTUFSNJOBM ɹɹɹ*.1301&34&561$"/3&46-5*/."-'6/$5*0/03'*3& ˰TFF4UFQ ᶅ3FNPUF7PMVNF$POUSPMMFS5FSNJOBMʢ &VSPCMPDLʣ ɹɹ6TFGPSDPOOFDUJOHBDPNNFSDJBMMZBWBJMBCMFWPMVNFDPOUSPM ˰TFF0QUJPO 4UFQɿ %*14XJUDI4FUUJOHT ˙4UFQ"*OJUJBM4FUVQ4XJUDIFT ɹɹ*.1035"/5*ODPSSFDUTFUUJOHTDBOEBNBHFZPVSFRVJQNFOU   4FUVQDBSFGVMMZUPFOTVSFTBGFPQFSBUJPO ɹɹ*.1035"/5%*14XJUDITFUUJOHDIBOHFTXJMMOPUBQQMZVOUJMUIFVOJUJTQPXFS   DZDMFECZSFNPWJOHUIF"$QPXFSDPSEGPSBXIJMF BOESFJOTFSUJOH  ɹɹ-PDLTUIFGSPOUQBOFMDPOUSPMTXJUIUIFFYDFQUJPOPGUIF1PXFSCVUUPOBOE.BTUFS7PMVNF  6OMPDL -PDL 

  • 1
  • 2

1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
SPEAKER OUT
Class2
Wiring
IR IN
RS232
AC
INLET
REMOTE VOL
SET UP
SOUND MODE
L
R
COM
70 V
2
Ω
- 8
Ω
100 V
(MONO)
(MONO/STEREO)
LINE IN
LINE OUT
MODEL NO.
PCA1120
100 -240 V
50 / 60 Hz
Input :
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
SPEAKER OUT
Class2
Wiring
IR IN
RS232
AC
INLET
REMOTE VOL
SET UP
SOUND MODE
L
R
COM
70 V
2
Ω
- 8
Ω
100 V
(MONO)
(MONO/STEREO)
LINE IN
LINE OUT
MODEL NO.
PCA1120
100 -240 V
50 / 60 Hz
Input :
(MONO)
(MONO/STEREO)
LINE IN
LINE OUT
(MONO)
(MONO/STEREO)
LINE IN
LINE OUT
MODEL NO.
PCA1120
#6, 7 [ IR Code ]
Set the IR ID of this unit to avoid mis-operation of multiple units.
#10 NOT USED
#9 [ Speaker Lo-Z ]
If Switch #8 is set to Lo-Z, you must adjust this switch according to your speaker specifications.
#8 [ SPEAKER OUT ]
Select Hi-Z or Lo-Z depending on your speaker specifications.
Hi-Z(70V / 100V)
Lo-Z(2Ω / 4Ω)
8
Lo-Z : 4Ω minimum
Lo-Z : 2Ω minimum
9
ID 1
(Same as MCA1120. This does not switch ID of MCA1120.)
ID 2
ID 3
6
7
Step 1:DIP Switch Settings
#5 [ Volume Control ]
Select which type of optional external volume controller: Volume Control(10kΩ、B-curve type),
or Infrared Remote System.
#2 [ Auto Standby ]
The PCA1120 automatically goes into the standby state after two hours when there is no audio
signal and no operation.
#3 [ Auto Power On ]
When an audio signal is detected on LINE IN during Standby, the power is turned on automatically.
#4 NOT USED
■ Step 1-A : [ SET UP ] Initial Setup Switches
IMPORTANT: Incorrect settings can damage your equipment.
Set up carefully to ensure safe operation.
IMPORTANT: DIP Switch setting changes will not apply until the unit is power
cycled by removing the AC power cord for a while, and reinserting.
#1 [ Keylock ]
Locks the front panel controls with the exception of the Power button and Master Volume.
On (LINEIN)
Off
3
Off
On
2
1
Lock
Unlock
Using a Volume Control (10kΩ) or Unusing an External Control
IR control
5
Step 2:Connecting Speakers
・Connect MCA1120 or external player to LINE IN terminals by RCA cable
.
You can use either L or R terminal for the output of monaural player.
Stereo signals are internally mixed into mono.
■ LINE IN Connection
Step 3:
Connecting MCA1120 or External Players
RCA
L
R
(MONO/STEREO)
LINE IN
・Connect the supplied AC power cord to the AC Inlet and plug to AC outlet.
Step 4:Connecting Power Cord
AC power cord
AC Inlet
To AC outlet
~~~
~~~
PCA1120 Rear Panel
① AC Inlet
(IEC C13, 100V-240V 50/60 Hz) (⇒ see Step 4)
② SPEAKER OUT Terminals
(Euroblock)
NOTE
It is important to read
“Step 2: Connecting Speakers”
before attempting to use this terminal.
IMPROPER SETUP CAN RESULT IN MALFUNCTION OR FIRE. (⇒ see Step 2)
③ Remote Volume Controller Terminal
(Euroblock)
Use for connecting a commercially available volume control. (⇒ see Option 2)
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
SPEAKER OUT
Class2
Wiring
IR IN
RS232
AC
INLET
REMOTE VOL
SET UP
SOUND MODE
L
R
COM
70 V
2
Ω
- 8
Ω
100 V
(MONO)
(MONO/STEREO)
LINE IN
LINE OUT
MODEL NO.
PCA1120
100 -240 V
50 / 60 Hz
Input :
④ LINE OUT Terminal
(RCA Mono)
Use this output to link to expansion amplifier PCA1120 like in Example A.
(⇒ see Option 1 for Setup)
⑤ LINE IN Terminals
(RCA Stereo)
Use to connect MCA1120 or an external player such as CD, Music Streamer, etc. (⇒ see Step 3)
⑥ IR IN
(3.5mm Mini, Mono/2-pole)
For use with an external infrared controller.
⑦ RS232
(3.5mm Mini, Stereo/3-Pole)
For use with an external controller, or for Custom EQ programming.
IMPORTANT
: To prevent damage, unplug the power cord when inserting/removing
the RS232 cable.
⑧ DIP Switches
See Step 1 for instructions on how to set the DIP switches.
● 1 x 120W at 4ohms, for commercial and industrial use
● Lo-Z(8/4/2 ohms) / Hi-Z(70/100V) compatible
● 1 input and loop out
● Preset EQ, HPF and LPF for loudspeakers
● Dynamic Loudness for comfortable BGM
● Setup done locally from rear panel
● Expandable with optional power amplifier PCA1120
● 1U rack mountable (with optional IRK-44-3)
MONO POWER AMPLIFIER
Instruction Manual
(This Document)
Safety Information
Warranty Card
Main Unit
AC Power Cord
5-pin Euroblocks (2)
Features
Package Contents
This product is intended for commercial/professional use.
It should be installed only by a specially-trained technician.
■ Example B
(IMAGE NOT SHOWN)
Driving a passive subwoofer
with the PCA1120.
■ Example A
Expanding the system
using the MCA1120, PCA1120(x2 shown)
and additional speakers.
PCA1120
■ Example C
Easy BGM system
・ ・ ・
■ Step 1-B : [ SOUND MODE ] Sound Preferences Switches
Advanced configuration tools for EQ and DSP.
TIP: These setting changes are instant. No power cycle is necessary.
#6,7 [ BGM Mode ]
Select a Sound Mode based on the intended
“mood”
of the listening environment.
If using this unit to expand the MCA1120, set to [ Off ].
The Sound Mode of the MCA1120 will
carry over.
#8-10 [ Preset EQ for Loudspeaker ]
Select the EQ preset for your speaker type(see list below).
#3-5 [ HPF (High Pass Filter) ]
Depending on the purpose of this unit, settings are different. Please refer description below.
* When it is used as speaker amplifier.
・Use this filter to limit bass frequencies to the SPEAKER OUT terminals. The DIP switches
set the cutoff frequency.
* Only if it is used as Subwoofer amplifier (When Switch #2 is [ On ])
・These settings are for low pass filter.
NOTE : Do not set to [ Off ] when using Hi-Z speaker or the amplifier may go into
protection mode.
NOTE : Settings of DIP switch are different from MCA1120.
50 Hz
40 Hz
60 Hz
70 Hz
90 Hz
4
5
3
150 Hz
200 Hz
Off
(No filter or using [Preset EQ for Loudspeaker])
Lively :
An Upbeat sound. Great for a Gym, or Club
Natural : A Balanced Sound for most spaces
Off :
Flat Frequency response (Select this when connecting to MCA1120)
Calm :
A Relaxed, Laid-Back sound. Great for a Cafe, etc.
6
7
#2 [ Subwoofer Mode ]
If PCA1120 is used as a subwoofer amp, set to [ On ].
NOTE:
Subwoofer Mode [ On ] changes the HPF switches (3,4,5) to Low Pass Filter values.
Off
On
2
#1 [ Music Optimizer ]
Advanced DSP improves the sound of compressed music formats, such as MP3.
Off
On
1
Type 1:Reserved for Onkyo
Type 2:Reserved for Onkyo
Type 3:Reserved for Onkyo
Off
8
9
10
Type 5:B16
Type 4:Reserved for Onkyo
Type 6:B40
Type 7:J24CT
1. Set #8 [ SET UP ] DIP switch [ SPEAKER OUT ] to [ Hi-Z ].
2. Connect the [ 100V ] or [ 70V ] terminal of SPEAKER OUT to
the + terminal on your speakers.
Next, connect the [ COM ] to
the ‒ terminal on your speakers.
■ Hi-Z (High Impedance) Connections
1. Set #8 [ SET UP ] DIP Switch [ SPEAKER OUT ] to [ Lo-Z ].
2.
Connect the + terminal of SPEAKER OUT to the + terminal on your speakers.
Next, connect the - to the ‒ terminal on your speakers.
■ Subwoofer Connections
(IMAGE NOT SHOWN)
・Confirm impedance of subwoofer. Then connect it by above either way.
■ Lo-Z (Low Impedance) Connections
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
Class2
Wiring
IR IN
RS232
AC
INLET
REMOTE VOL
SET UP
SOUND MODE
L
R
COM
70 V
2
Ω
- 8
Ω
100 V
100 -240 V
50 / 60 Hz
Input :
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
Class2
Wiring
RS232
AC
INLET
REMOTE VOL
SET UP
SOUND MODE
L
R
COM
70 V
2
Ω
- 8
Ω
100 V
100 -240 V
50 / 60 Hz
Input :
COM
70 V
2
Ω
- 8
Ω
100 V
~~
~~
■ When connecting
100V line
speakers
■ When connecting
70V line
speakers
SPEAKER OUT
COM
70 V
2
Ω
- 8
Ω
100 V
COM
70 V
2
Ω
- 8
Ω
100 V
System Configuration Examples
NOTE: It is important to read
“Step 2: Connecting Speakers”
before setting this switch.
IMPROPER SETUP CAN RESULT IN MALFUNCTION OR FIRE.
(⇒ see Step 2 for details)
NOTE: It is important to read
“Step 2: Connecting Speakers”
before setting this switch.
IMPROPER SETUP CAN RESULT IN MALFUNCTION OR FIRE.
(⇒ see Step 2 for details)
Connect AC power cord in final step.
Do not connect AC power cord before this step.
It may cause electric shock.
Check the connection pins of Euroblock and Lo-Z / Hi-Z settings of DIP switches
according to speaker specifications.
If these are not matched, it may cause malfunction or fire.
Pay close attention to speaker setting /
connection!
It may cause malfunction or fire.
SN 29403547A
2
*
9
4
0
3
5
4
7
A
Instruction Manual
See website for detailed connections.
Speakers
Step 2
AC Power
Step 4
Step 3
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
SPEAKER OUT
Class2
Wiring
IR IN
RS232
AC
INLET
REMOTE VOL
SET UP
SOUND MODE
L
R
COM
70 V
2
Ω
- 8
Ω
100 V
(MONO)
(MONO/STEREO)
LINE IN
LINE OUT
MODEL NO.
PCA1120
100 -240 V
50 / 60 Hz
Input :
DIP Switches
1
2
3
4
5
6
7
8
9
10
Step 1
Setup Steps
Option 1
Speaker Expansion
Option 2
Remote
Volume Controller
PCA1120
MCA1120 or
External Player
In the main space
MCA1120
In the VIP area
PCA1120
In the terrace area
PCA1120
Lo-Z speakers
Composite impedance 2Ω or more
・ ・ ・
Hi-Z
speakers
Rated total 120W or less
Drip-proof speaker
Hi-Z 120W or less /
Lo-Z 2Ω or more
・ ・ ・
・ ・ ・
Lo-Z speakers
Composite impedance 2Ω or more
The PCA1120 has built-in crossover settings for this application.
・Do not use the high impedance 70V line and 100V line terminals at the same time.
・Make sure that the total rated input power of the connected speakers is 120W or less.
・Do not connect the Lo-Z speakers to the Hi-Z terminals.
・When connecting multiple speakers, make sure that the total impedance is more than
the value of setting #9 [ Speaker Lo-Z ] of SET UP DIP switch.
In this configuration with multiple rooms and speaker types,
the MCA1120 controls the overall volume of the system, while each
PCA1120 volume level can be adjusted for its room.
MODEL NO.
PCA1120
*