Oregon Scientific EMR201 User Manual 2 - Page 1

Oregon Scientific EMR201 Manual

Page 1 highlights

Wireless Indoor and Outdoor Thermometer with LED Ice Alert Model: EMR201 USER MANUAL OVERVIEW FRONT VIEW OUT TEMP 1 2 IN TEMP 3 4 1. Remote sensor reception indicator 2. Outdoor temperature 3. Indoor temperature 4. Ice alert LED indicator BACK VIEW 1 2 RESET C/ F 1. °C / °F: Select temperature unit 2. RESET: Reset unit to default settings REMOTE SENSOR 2 1 4 3 5 1. LED status indicator 2. Wall mount hole 3. Battery compartment 4. RESET hole 5. CHANNEL switch GETTING STARTED INSERT BATTERIES 1. Remove the battery compartment. 2. Insert the batteries, matching the polarities (see FIG 2). 3. Press RESET after each battery change. LOCATION Indoor temperature area Outdoor temperature area MEANING Main unit batteries low Sensor batteries low REMOTE SENSOR To set up the sensor: 1. Open the battery compartment (see FIG 3). 2. Select channel 1 then press RESET. 3. Close the battery door. 4. Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount. TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 5 ft and which can shield it from direct sunlight or wet conditions for an accurate reading. NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. SENSOR DATA TRANSMISSION To search for a sensor: Reset the unit. The sensor reception icon in the remote sensor area shows the status: ICON DESCRIPTION OUT OUT Main unit is searching for sensor(s). OUT OUT OUT OUT A channel has been found. OUT The sensor cannot be found. TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. ICE WARNING If the channel 1 sensor falls between 3°C to -2 °C (37°F to 28°F), LED indicator will flash, and will stop flashing once the temperature is out of this range. RESET Press RESET to return to the default settings. PRECAUTIONS • Do not subject the unit to excessive force, shock, dust, temperature or humidity. • Do not cover the ventilation holes with any items such as newspapers, curtains etc. • Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. • Do not clean the unit with abrasive or corrosive materials. • Do not tamper with the unit's internal components. This invalidates the warranty. • Only use fresh batteries. Do not mix new and old batteries. • Images shown in this manual may differ from the actual display. • When disposing of this product, ensure it is collected separately for special treatment. • Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information. • The contents of this manual may not be reproduced without the permission of the manufacturer. • Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. • Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use. NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice. SPECIFICATIONS TYPE DESCRIPTION MAIN UNIT L x W x H 66 x 27.5 x 87.5 mm (2.59 x 1.08 x 3.44 in) Weight 241 g (8.5 oz) without battery Temperature range -5°C to 50°C (23°F to 122°F) Resolution 0.1°C (0.2°F) Signal frequency 433 MHz Humidity range 25% - 95% Humidity resolution 1% Power 2 x UM-4 (AAA) 1.5 V batteries REMOTE UNIT (THN132N) L x W x H 96 x 50 x 22 mm (3.78 x 1.97 x 0.87 in) Weight 62 g (2.22 ounces) Transmission range 30 m (98 ft) unobstructed Temperature range -20°C to 60°C (-4°F to 140°F) Power 1 x UM-3 (AA) 1.5 V batteries ABOUT OREGON SCIENTIFIC Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you're in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientific.com/service/support OR Call 1-800-853-8883. For international inquiries, please visit: www2.oregonscientific.com/about/international FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio / TV technician for help. DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com, or on the warranty card for this product) for all inquiries instead. We Name: Address: Telephone No.: Oregon Scientific, Inc. 19861 SW 95th Ave.,Tualatin, Oregon 97062 USA 1-800-853-8883 declare that the product Product No.: EMR201 Product Name: Wireless Indoor and Outdoor Thermometer with LED Ice Alert Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1,41 Man Yue St., Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. © 2007 Oregon Scientific. All rights reserved. P/N: 086L005000-011

  • 1

OVERVIEW
FRONT VIEW
1.
Remote sensor reception indicator
2.
Outdoor temperature
3.
Indoor temperature
4.
Ice alert LED indicator
BACK VIEW
1.
°C / °F
: Select temperature unit
2.
RESET
: Reset unit to default settings
REMOTE SENSOR
1.
LED
status indicator
2.
Wall mount hole
3.
Battery compartment
4.
RESET
hole
5.
CHANNEL
switch
GETTING STARTED
INSERT BATTERIES
1.
Remove the battery compartment.
2.
Insert the batteries, matching the polarities (see
FIG 2).
3.
Press
RESET
after each battery change.
Wireless Indoor and
Outdoor Thermometer
with LED Ice Alert
Model: EMR201
USER MANUAL
4
2
3
1
TEMP
TEMP
IN
OUT
�±²³´µ²¶·
RESET
C/ F
2
1
REMOTE SENSOR
To set up the sensor:
1.
Open the battery compartment (see FIG 3).
2.
Select channel 1 then press
RESET
.
3.
Close the battery door.
4.
Place the sensor within 30 m (98 ft) of the main
unit using the table stand or wall mount.
TIP
Ideal placements for the sensor would be in any
location on the exterior of the home at a height of
not more than 5 ft and which can shield it from direct
sunlight or wet conditions for an accurate reading.
NOTE
Use alkaline batteries for longer usage and
consumer grade lithium batteries in temperatures
below freezing.
SENSOR DATA TRANSMISSION
To search for a sensor:
Reset the unit.
The sensor reception icon in the remote sensor area
shows the status:
TIP
The transmission range may vary depending
on many factors. You may need to experiment with
various locations to get the best results.
ICE WARNING
If the channel 1 sensor falls between 3°C to -2 °C
(37°F to 28°F), LED indicator will flash, and will stop
flashing once the temperature is out of this range.
RESET
Press
RESET
to return to the default settings.
PRECAUTIONS
Do not subject the unit to excessive force,
shock, dust, temperature or humidity.
Do not cover the ventilation holes with any items
such as newspapers, curtains etc.
Do not immerse the unit in water. If you spill
liquid over it, dry it immediately with a soft,
lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do
not
tamper
with
the
unit’s
internal
components. This invalidates the warranty.
Only use fresh batteries. Do not mix new and
old batteries.
Images shown in this manual may differ from
the actual display.
When disposing of this product, ensure it is
collected separately for special treatment.
LOCATION
MEANING
Indoor temperature
area
Outdoor temperature
area
Main unit batteries low
Sensor batteries low
ICON
DESCRIPTION
Main unit is searching
for sensor(s).
A channel has been
found.
The sensor cannot be
found.
OUT
OUT
OUT
OUT
OUT
OUT
OUT
Placement of this product on certain types
of wood may result in damage to its finish for
which Oregon Scientific will not be responsible.
Consult
the
furniture
manufacturer’s
care
instructions for information.
The contents of this manual may not be
reproduced without the permission of the
manufacturer.
Do not dispose old batteries as unsorted
municipal waste. Collection of such waste
separately for special treatment is necessary.
Please note that some units are equipped with
a battery safety strip. Remove the strip from the
battery compartment before first use.
NOTE
The technical specifications for this product
and the contents of the user manual are subject to
change without notice.
SPECIFICATIONS
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to
learn more about Oregon Scientific products. If
you’re in the US and would like to contact our
Customer Care department directly, please visit:
www2.oregonscientific.com/service/support
OR
Call 1-800-853-8883.
For international inquiries, please visit:
www2.oregonscientific.com/about/international
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) This device must accept any interference
received, including interference that may cause
undesired operation.
WARNING
Changes or modifications not expressly
approved by the party responsible for compliance
could void the user’s authority to operate the
equipment.
NOTE
This equipment has been tested and found
to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection
against
harmful
interference
in
a
residential
installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference
will not occur in a particular installation. If this
equipment does cause harmful interference to radio or
television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one
or more of the following measures:
TYPE
DESCRIPTION
MAIN UNIT
L x W x H
241 g (8.5 oz) without battery
66 x 27.5 x 87.5 mm
(2.59 x 1.08 x 3.44 in)
Weight
Temperature range
-5°C to 50°C (23°F to 122°F)
Resolution
0.1°C (0.2°F)
Signal frequency
433 MHz
Humidity range
25% - 95%
Humidity resolution
1%
Power
2 x UM-4 (AAA)
1.5 V batteries
REMOTE UNIT (THN132N)
L x W x H
96 x 50 x 22 mm
(3.78 x 1.97 x 0.87 in)
Weight
62 g (2.22 ounces)
Transmission range
30 m (98 ft) unobstructed
Temperature range
-20°C to 60°C (-4°F to 140°F)
Power
1 x UM-3 (AA) 1.5 V batteries
·
Reorient or relocate the receiving antenna.
·
Increase the separation between the equipment
and receiver.
·
Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
·
Consult the dealer or an experienced radio / TV
technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as
contact for support or sales. Please call our
customer service number (listed on our website at
www.oregonscientific.com, or on the warranty card
for this product) for all inquiries instead.
We
Name:
Oregon Scientific, Inc.
Address:
19861 SW 95th Ave.,Tualatin,
Oregon 97062 USA
Telephone No.:
1-800-853-8883
declare that the product
Product No.:
EMR201
Product Name:
Wireless Indoor and Outdoor
Thermometer with LED Ice
Alert
Manufacturer:
IDT Technology Limited
Address:
Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
is in conformity with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference
received, including interference that may cause
undesired operation.
© 2007 Oregon Scientific. All rights reserved.
P/N: 086L005000-011
2
3
4
5
1