Oregon Scientific RMR329PA User Manual - Page 1
Oregon Scientific RMR329PA Manual
View all Oregon Scientific RMR329PA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Radio-Controlled Projection Clock with Indoor / Outdoor Temperature Model: RMR329PA USER MANUAL EN INTRODUCTION Thank you for selecting this Oregon Scientific™ RadioControlled Projection Clock with Indoor / Outdoor Temperature. Please keep this manual for instructions and information you should know about. CLOCK OVERVIEW FRONT VIEW 1 5 2 6 3 4 1. LED status indicator 2. Wall mount hole 3. Battery compartment 4. RESET hole: Reset unit to default settings 5. CHANNEL button: Select channel 1 GETTING STARTED POWER SUPPLY Batteries serve as a back-up power supply. For continuous use of projector and backlight, install adapter. The socket-outlet shall be installed near the equipment and shall be easily accessible. NOTE will appear when power supply is not connected. To insert batteries: 1. Remove the battery compartment and insert batteries, matching polarities. 2. Press RESET after each battery change. LOCATION Clock / alarm area Outdoor / indoor temperature area MEANING Main unit batteries low Sensor batteries low REMOTE SENSOR To set up the sensor: 1. Open the battery compartment, and insert batteries, matching polarities. 2. Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount. 1. SNOOZE: Snooze alarm; activate backlight; rotate dual line projection display by 180° 2. ALARM: View alarm status; set alarm 3. CLOCK: Change display; set clock 4. / : Toggle setting options; activate / deactivate clock reception 5. Projector 6. TEMP: Toggle in / out temperature settings BACK VIEW 1 3 4 5 2 6 7 8 1. FOCUS: Focus the projected image 2. Battery compartment 3. Light sensor 4. PROJECTION: ON / OFF switch 5. LIGHT: Backlight ON / OFF switch 6. °C / °F: Select temperature unit 7. RESET: Reset settings to default 8. Adapter socket REMOTE SENSOR 2 1 4 3 5 The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. NOTE We recommend that you use alkaline batteries with this product for longer usage and consumer grade lithium batteries in temperatures below freezing. SENSOR DATA TRANSMISSION Outdoor sensor: The main unit will automatically search for the outdoor sensor. The sensor reception icon in the remote sensor area shows the status: ICON DESCRIPTION Main unit is searching for sensor(s) A channel has been found The sensor cannot be found. NOTE If the sensor is not found, check the batteries, obstructions, and remote unit location. For best results: • Place the sensor out of direct sunlight and moisture. • Position the sensor facing main unit, minimizing obstructions. • Place the sensor in a location with a clear view to the sky, away from metallic or electronic objects. • Position the sensor close to the main unit during cold winter months. CLOCK CLOCK RECEPTION This product is designed to synchronize its clock automatically with a clock signal. To enable / disable signal reception: Touch and hold to enable, or to disable signal signal reception. NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. Clock signal reception indicator: STRONG SIGNAL WEAK SIGNAL NO SIGNAL MANUALLY SET CLOCK 1. Press and hold CLOCK for 2 seconds. 2. Press or to change the settings. 3. Press CLOCK to confirm. 4. The setting order is: time zone offset, 12/24-hr format, hour, minute, year, day / month format, month, day and language. NOTE Time zone offset sets the clock +/- 23 hours from the received clock signal time. NOTE The language options are (E) English, (D) German, (F) French, (I) Italian, and (S) Spanish. To select display mode: Press CLOCK to choose between clock with seconds and clock with weekday. ALARM To set the alarm: 1. Press and hold ALARM for 2 seconds to enter alarm-setting mode. 2. Press / to set hour / minute. 3. Press ALARM to confirm. indicates alarm is ON. To toggle alarms ON / OFF: 1. Press ALARM to display alarm time. 2. Press ALARM again to turn alarm ON / OFF. To silence the alarms: • Press SNOOZE to silence it for 8 minutes OR • Press any other key to turn the alarm off and activate it again after 24 hours. TEMPERATURE To toggle temperature unit: Press °C / °F. To toggle between outdoor / indoor sensor readings: Press TEMP. / indicates indoor and outdoor temperature. To auto-scan between sensors: Press and hold TEMP for 2 seconds to display the sensor's data for 5 seconds. To deactivate auto-scan function press TEMP. PROJECTOR AND BACKLIGHT To activate Projection function: • Slide PROJECTION switch to ON to illuminate projection continuously. To activate Backlight function: • Slide LIGHT switch to ON to illuminate backlight continuously. OR • Press SNOOZE to turn on projector and backlight for 5 seconds. • Press repeatedly to flip dual line projection image by 180 degrees. NOTE If projection is illuminated, do not look directly into the projector. NOTE To save battery life, the projector and backlight will only operate continuously when adapter is installed. The light sensor will turn off the projector automatically when it detects external light sources. RESET Press RESET to return to the default settings. PRECAUTIONS • Do not subject the unit to excessive force, shock, dust, temperature or humidity. • Do not cover the ventilation holes with any items such as newspapers, curtains etc. • Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. • Do not clean the unit with abrasive or corrosive materials. • Do not tamper with the unit's internal components. This invalidates the warranty. • Only use fresh batteries. Do not mix new and old batteries. • Images shown in this manual may differ from the actual display. • When disposing of this product, ensure it is collected separately for special treatment. • Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacture's care instructions for information. • The contents of this manual may not be reproduced without the permission of the manufacturer. • Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. • Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use. NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice. SPECIFICATIONS TYPE DESCRIPTION MAIN UNIT L x W x H 155 x 50 x 112 mm (6.1 x 1.97 x 4.41 in) Weight 240 g (8.5 oz) without battery Temperature Unit °C / °F Temperature range -5°C to 50°C (23°F to 122°F) Resolution 0.1°C (0.2°F) Signal frequency 433 MHz Power 3 x UM-4 (AAA) 1.5V batteries / 4.5V AC / DC adapter REMOTE UNIT (THN132N) L x W x H 92 x 60 x 20 mm (3.6 x 2.4 x 0.8 in) Weight 62 g (2.22 ounces) Transmission range 30 m (98 ft) unobstructed Temperature range -30°C to 60°C (-22°F to 140°F) Power 1 x UM-3 (AA) 1.5V battery ABOUT OREGON SCIENTIFIC Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you're in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientifi c.com/service/support OR Call 1-800-853-8883. For international inquiries, please visit: www2.oregonscientifi c.com/about/international FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio / TV technician for help. DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com), or on the warranty card for this product) for all inquiries instead. We Name: Address: Telephone No.: Fax No.: Oregon Scientific, Inc. 19861 SW 95th Ave., Tualatin, Oregon 97062 USA 1-800-853-8883 1-503-684-3332 declare that the product Product No.: RMR329PA Product Name: Radio-Controlled Projection Clock with Indoor / Outdoor Temperature Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1,41 Man Yue St., Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. COUNTRIES RTTE APPROVAL COMPLIED All EU countries, Switzerland CH and Norway N Horloge de projection radio-pilotée avec affichage de la température intérieure / extérieure Modèle: RMR329PA MANUEL DE L'USAGER FR INTRODUCTION Nous vous remercions d'avoir sélectionné cette Horloge de projection radio-pilotée de Oregon Scientific™ avec affichage de la température intérieure et extérieure. Veuillez conserver ce guide et prendre connaissance des instructions et informations nécessaires à l'utilisation. VUE D'ENSEMBLE DE L'HORLOGE VUE AVANT 1 5 2 6 3 4 1. SNOOZE (Rappel d'alarme): Permet d'activer le rappel d'alarme, le rétro éclairage, permet la rotation de l'image projetée sur deux lignes par 180° 2. ALARM: Visualisation du statut de l'alarme ; réglage de l'alarme 3. CLOCK: Permet de modifier l'affichage de l'horloge et de régler l'horloge 4. / : Permet d'alterner entre les options de réglage, active / désactive la réception de l'horloge 5. Projecteur 6. TEMP: Permet d'alterner entre les réglages de la température intérieure et extérieure FACE ARRIERE 1 3 4 5 2 6 7 8 1. FOCUS: Mise au point de l'image projetée 2. Compartiment des piles 3. Capteur de lumière 4. PROJECTION: Bouton ON / OFF 5. LIGHT: Bouton ON / OFF du rétro éclairage 6. °C / °F: Permet de sélectionner l'unité de mesure de la température 7. RESET (REINITIALISER): Permet de réinitialiser les réglages par défaut 8. Prise de l'adaptateur DETECTEUR A DISTANCE 2 1 4 3 5 1. Indicateur DEL 2. Trou de fixation murale 3. Compartiment des piles 4. Fente RESET (RÉINITIALISER): Réinitialise l'appareil aux réglages par défaut 5. Bouton CHANNEL: Permet de sélectionner le canal 1 POUR COMMENCER ALIMENTATION ELECTRIQUE Les piles n'ont qu'une fonction d'alimentation de secours. Si vous désirez utiliser continuellement le projecteur et le rétro éclairage, branchez l'adaptateur secteur. La prise de courant doit être installée à proximité de l'équipement et facilement accessible. REMARQUE s'affichera une fois le cordon d'alimentation électrique branché. Insérer les piles: 1. Retirez le couvercle du compartiment des piles et insérez les piles en respectant les polarités. 2. Appuyez sur REINITIALISER (RESET) après chaque changement de piles. EMPLACEMENT Zone Horloge / alarme Zone de température extérieure / intérieure SIGNIFICATION Piles faibles (Appareil principal) Piles du capteur faibles CAPTEUR A DISTANCE Installation du capteur: 1. Ouvrez le compartiment des piles et insérez les piles en respectant les polarités. 2. Installez le capteur à 30 m maximum (98 pieds) de l'appareil principal à l'aide du support de table ou de la fixation murale. La gamme de transmission peut varier en fonction de plusieurs facteurs. Vous pouvez expérimenter plusieurs emplacements afin d'obtenir les meilleurs résultats possibles. REMARQUE Nous vous recommandons d'utiliser des piles alcalines pour un usage prolongé et des piles au lithium pour la consommation lors de températures inférieures au gel. TRANSMISSION DES DONNEES DU CAPTEUR L'appareil principal recherchera immédiatement le capteur extérieur. L'icône de réception du capteur sur la zone du capteur à distance vous indique le statut de la transmission: ICONE DESCRIPTION L'appareil principal est à la recherche du/des capteur(s) Une chaîne a été trouvée Le capteur est introuvable REMARQUE Si le capteur n'est pas localisé, vérifiez les piles, les obstructions possibles et l'emplacement du capteur à distance. Pour obtenir de meilleurs résultats: • Ne placez pas le capteur directement face aux rayons du soleil ou en contact avec des matières humides. • Installez le capteur face à l'appareil principal en réduisant les obstructions possibles. • Placez le capteur directement vers le ciel, éloigné des objets métalliques et électroniques. • Installez le capteur à proximité de l'appareil principal pendant les périodes froides de l'hiver. HORLOGE RECEPTION DE L'HORLOGE Ce produit est conçu pour synchroniser automatiquement l'horloge avec le signal radio. Pour activer / désactiver la réception du signal: Maintenez le bouton pour activer ou pour désactiver le signal de réception. REMARQUE La réception prend entre 2 et 10 minutes. Si le signal est faible, 24 heures peuvent être nécessaires pour obtenir un signal valide. Indicateur de réception du signal de l'Horloge: SIGNAL FORT SIGNAL FAIBLE PAS DE SIGNAL REGLER MANUELLEMENT L'HORLOGE 1. Maintenez le bouton CLOCK pendant 2 secondes. 2. Appuyez sur ou pour changer les réglages. 3. Appuyez sur CLOCK pour confirmer. 4. L'ordre de réglage est le suivant : Fuseau horaire, format 12/24 heures, heure, minutes, année, format jour/mois, mois, jour et la langue. REMARQUE La fonction de décalage horaire règle l'horloge à +/- 23 heures de l'heure du signal reçu. REMARQUE Les langues disponibles sont l'anglais (E), le français (F), l'allemand (D), l'italien (I) et l'espagnol (S). Pour sélectionner le mode d'affichage: Appuyez sur CLOCK pour choisir entre l'horloge avec les secondes et l'horloge avec les jours de la semaine. ALARME Pour régler l'alarme: 1. Maintenez le bouton ALARM pendant 2 secondes pour entrer dans le mode de réglage de l'alarme. 2. Appuyez sur / pour régler l'heure / les minutes. 3. Appuyez sur ALARM pour confirmer. indique que l'alarme est activée. Pour activer/désactiver l'alarme: 1. Appuyez sur ALARM pour afficher l'heure de l'alarme. 2. Appuyez une nouvelle fois sur ALARM pour la mettre sur ON / OFF. Pour couper le son de l'alarme: • Appuyez sur SNOOZE, pour couper le son pendant 8 minutes OU • Appuyez sur n'importe quel bouton pour éteindre l'alarme et pour qu'elle se déclenche 24 heures plus tard. TEMPERATURE Pour sélectionner l'unité de température: Appuyez sur °C / °F. Pour alterner entre les lectures du capteur intérieur ou extérieur: Appuyez sur TEMP. / intérieure et extérieure. indique la température Pour activer l'auto balayage entre les capteurs: Maintenez le bouton TEMP pendant 2 secondes pour afficher les données du capteur pendant 5 secondes. Pour désactiver la fonction auto balayage, appuyez sur TEMP. PROJECTEUR ET RETRO ECLAIRAGE Pour activer la fonction Projection: • Positionnez le bouton PROJECTION sur ON pour activer continuellement la projection. Pour activer la fonction Rétro Eclairage: • Positionnez le bouton LIGHT sur ON pour activer continuellement la rétro éclairage. OU • Appuyez sur SNOOZE pour activer le projecteur et le rétro éclairage pendant 5 secondes. • Appuyez plusieurs fois pour renverser l'image projetée sur deux lignes par 180°. REMARQUE Si la projection est activée, ne regardez pas directement dans le projecteur. RMR329PA_086L004937-011.indd 1 6/5/07 9:58:16 AM