Panamax MIW-POWER Datasheet - Page 1

Panamax MIW-POWER Manual

Page 1 highlights

MAX In-Wall™ POWER The MAX In-Wall™ POWER discreetly delivers safe AC power and protects the customer's display in a UL approved, code compliant manner. This is how it works: remote audio/video equipment is powered by a branch circuit separate from the main system. If A/V signals are distributed from the main system to remote equipment, multiple ground references are created, making all equipment susceptible to voltage-differential surge damage. The MIW-POWER module combines AC surge protection with a bay for signal protection modules (sold separately). With a module in the bay, AC and signal lines are bonded together, creating one Isolated Ground Reference for the remote equipment. Simply remove the panel and replace it with the appropriate signal line module. GENERAL Product Name MAX In-Wall™ Power Part Number MIW-Power Retail Price 49.95 Application Custom Home Theater Systems Power Cord NO (hard-wired) Signal line modules may be mounted flush with faceplate, half-recess or with full recess. Modules can be removed or depthadjusted with the included puller. AC CIRCUIT AC Outlets, Total 1 AC 120V, 60Hz, 15A Clamping 400V L-N, L-G & N-G Energy Dissipation 675 joules (8x20ms) Current Capacity 26,000 Amps (8x20ms) SignalLine Protection Not Included / Modules Sold Separately UL® / cUL Listed (1449 2nd Edition YES PRODUCT WARRANTY Product Warranty 3 years For new construction (pre-wire): Use a Carlon® newwork electrical box (Model # B122A-UPC). A Carlon low voltage add-on bracket (Model # SC100SC) may be used with the new-work box to indicate the size and location of the opening needed in the drywall. The lowvoltage bracket may be left in place when installing the MIW-POWER. ORDERING INFORMATION Unit Dimensions 4.38"W x 3.81"L x 4.38"H Individual Unit UPC 0 50616 00735 1 Packaging Type Retail Box Packaging Dimensions 4.75"W x 4.00"L x 4.75"H Unit Weight (packaged 1 lbs. Units per Inner Pack 3 Inner Pack UPC 3 00 50616 00735 2 Inner Pack Dimensions 14.0"W x 5.50"L x 5.19"H Inner Pack Weight 4.45 lbs. Units per Master Carton 12 (4 Inner Packs) Master Carton UPC 5 00 50616 00735 6 Master Carton Dimensions 14.75"W x 11.25"D x 10.75"H B122A-UPC Single-Gang Box SC100SC Low Voltage Add-On Bracket * Patent-Pending #L507, 6/2004 The Power Specialists Since 1975 1690 Corporate Circle, Petaluma, CA 94954 • (800) 472-5555 • www.panamax.com

  • 1

MAX In-Wall
POWER
The Power Specialists Since 1975
1690 Corporate Circle, Petaluma, CA 94954 • (800) 472-5555 • www.panamax.com
The
MAX In-Wall™ POWER
discreetly delivers
safe AC power and protects the customer’s
display in a UL approved, code compliant
manner.
This is how it works:
remote
audio/video equipment is powered by a
branch circuit separate from the main system.
If A/V signals are distributed from the main
system to remote equipment, multiple ground
references are created, making all equipment
susceptible to voltage-differential surge
damage. The
MIW-POWER
module combines
AC surge protection with a bay for signal protection modules (sold separately).
With a module in the bay,AC and signal lines are bonded together, creating one
Isolated Ground Reference for the remote equipment.
GENERAL
Product Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MAX In-Wall™ Power
Part Number
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MIW-Power
Retail Price . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$49.95
Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Custom Home Theater Systems
Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NO (hard-wired)
AC CIRCUIT
AC Outlets, Total . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V, 60Hz, 15A
Clamping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400V L-N, L-G & N-G
Energy Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .675 joules (8x20ms)
Current Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26,000 Amps (8x20ms)
SignalLine Protection . . . . . . . . . . . . . . .Not Included / Modules Sold Separately
UL® / cUL Listed (1449 2nd Edition) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .YES
PRODUCT WARRANTY
Product Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 years
ORDERING INFORMATION
Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.38”W x 3.81”L x 4.38”H
Individual Unit UPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 50616 00735 1
Packaging Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Retail Box
Packaging Dimensions . . . . . . . . . . . . . . . . . . . . . . . . .4.75”W x 4.00”L x 4.75”H
Unit Weight (packaged) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 lbs.
Units per Inner Pack
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Inner Pack UPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 00 50616 00735 2
Inner Pack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . .14.0”W x 5.50”L x 5.19”H
Inner Pack Weight
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.45 lbs.
Units per Master Carton . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 (4 Inner Packs)
Master Carton UPC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 00 50616 00735 6
Master Carton Dimensions . . . . . . . . . . . . . . . . . . .14.75”W x 11.25”D x 10.75”H
Simply remove the panel and replace it with
the appropriate signal line module.
For new construction (pre-wire):
Use a Carlon
®
new-
work electrical box
(Model # B122A-UPC).
A Carlon low voltage
add-on bracket
(Model # SC100SC)
may be used with the
new-work box to indicate the size and location
of the opening needed in the drywall. The low-
voltage bracket may be left in place when
installing the
MIW-POWER
.
Signal line
modules
may be mounted flush
with faceplate, half-recess or with full
recess. Modules can be removed or depth-
adjusted with the included puller.
SC100SC
Low Voltage Add-On
Bracket
B122A-UPC
Single-Gang Box
* Patent-Pending