TALLY CONNECTOR, Pin assignment, Pin No., Signal name, Input/output, Description of signal - av hs300g
View all Panasonic AVHS300G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
6. External interfaces 6-3. Tally connector The tally connector comes with tally output, output enable, power supply or fan alarm output pins. The output signals from the tally output pins are for lighting the tally lamps, and these outputs are open collector outputs. 12345 6 789 Pin assignment Pin No. 1 2 3 4 5 6 7 Signal name IN1 IN2 IN3 IN4 IN5 IN6 ENABLE 8 ALARM 9 GROUND Input/output Open collector output Open collector output Open collector output Open collector output Open collector output Open collector output Input Open collector output GROUND Description of signal Tally output of input video 1 Tally output of input video 2 Tally output of input video 3 Tally output of input video 4 Tally output of input video 5 Tally output of input video 6 Enable signal of tally output Open: Output; GND: no output Fan alarm or power supply alarm output Ground Pins 1 to 6 and pin 8 must satisfy the following conditions: Dielectric strength: Max. DC 24 V Current: Max. 50 mA Example of tally connections AV-HS300G (Max. voltage: 24V) Tally, Alarm output (IN1 to 6, ALARM) (Max. current: 50mA) GROUND Tally LED 52