Panasonic CS-ME9SB4U Full Line Catalog - Page 48

Multi-Split Tube Adaptors

Page 48 highlights

Multi-Split Tube Adaptors Model Number CU-5E36QBU-5 2-Zone Suction Discharge 3/8" 1/4" 3/8" 1/4" 3-Zone Outdoor Unit 3/8" 1/4" CZ-MA1P-US-BUND Flare Nut 3/8" 1/2" (Indoor Connection Port) 12 or 18 kBtu/h Indoor Unit Line Set 3/8" 1/4" Suction Discharge 3/8" Indoor 5, 7 and 9k Btu/h have 1/4" Unit 1/4" and 3/8" flare connection 3/8" 3/8" 1/2" 1/2" Indoor 12 and 18 kBtu/h have 1/4" Unit 1/4" and 1/2" flare connection 1/4" 3/8" 3/8" Indoor 1/4" X 3/8" line set used for 1/4" Unit 5K, 7K, 9K, 12K & 18K 1/4" 4-Zone 5-Zone 3/8" 1/4" X 3/8" line set used for 3/8" 1/4" 3/8" 1/4" Indoor Unit 5K, 7K, 9K, 12K & 18K 1/4" X 1/2" line set for 24K 1/4" 1/4" X 1/2" line set used for 24K 3/8" 3/8" 1/2" 1/2" 1/2" 5/8" 5/8" 1/4" Indoor indoor unit Unit 1/4" Indoor unit flare connection 1/4" X 5/8" 1/4" CZ-MA2P-US-BUND 3/8" (Outdoor Connection Port) Flare Nut 1/2" CZ-MA3P-US-BUND Flare Nut 1/2" 5/8" (Indoor Connection Port) 24kBtu/h Indoor Unit (Qty) and Adaptor Required for Multi Zone Installations Adaptor Chart 2 Zone CU-2E18NBU CU-2E18SBU-5 O/D I/D CS-ME5RKUA none CS-ME7RKUA none CS-E9RKUAW none Wall Mount CS-E12RKUAW none CS-E18RKUAW N/A CS-E24RKUAW N/A CS-ME9SB4U none 4-Way CS-E12RB4UW none CS-E18RB4UW N/A none none none (1) MA1P N/A N/A none (1) MA1P N/A CS-ME5SD3UA none CS-ME7SD3UA none Slim Duct CS-E9SD3UAW none CS-E12SD3UAW none CS-E18SD3UAW N/A none none none (1) MA1P N/A none - no adaptor required N/A - indoor does not match capacity of outdoor Ducted Multi-Zone Applications Available March 2017. 2-3 Zone CU-3E19RBU-5 O/D I/D none none none none none none none (1) MA1P none (1) MA1P N/A N/A none none none (1) MA1P N/A (1) MA1P none none none none none none none (1) MA1P N/A (1) MA1P Adaptor Model CZ-MA1P-US-BUND CZ-MA2P-US-BUND (male/female) 3/8" M x 1/2"F 3/8" F x 1/2"M CZ-MA3P-US-BUND Flare Nut (included) 1/2" M x 5/8"F Note: Flare nut is usually supplied with all line sets. Panasonic also provides flare nut with adaptor for contractor convenience. 47 Tube Size Adaptor with Flare Nut CZ-MA1P-US-BUND CZ-MA2P-US-BUND CZ-MA3P-US-BUND 2-4 Zone CU-4E24RBU-5 O/D none none none none none (1) MA2P none none none none none none none none I/D none none none (1) MA1P (1) MA1P (1) MA3P none (1) MA1P (1) MA1P none none none (1) MA1P (1) MA1P 2-5 Zone CU-5E36QBU-5 O/D none none none none none (1) MA2P none none none none none none none none I/D none none none (1) MA1P (1) MA1P (1) MA3P none (1) MA1P (1) MA1P none none none (1) MA1P (1) MA1P Flare Nut Tube Adaptors

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

Tube Size Adaptor with Flare Nut
CZ-MA1P-US-BUND
CZ-MA2P-US-BUND
CZ-MA3P-US-BUND
3/8"
1/4"
3/8"
1/4"
3/8"
1/4"
3/8"
1/4"
1/4" X 1/2" line set used for 24K
1/2"
1/4"
3/8"
1/4"
3/8"
1/4"
Indoor
Unit
5, 7 and 9k Btu/h have
1/4" and 3/8" flare connection
3/8"
1/4"
1/2"
1/4"
Indoor
Unit
12 and 18 kBtu/h have
1/4" and 1/2" flare connection
3/8"
1/4"
3/8"
1/4"
Indoor
Unit
1/4" X 3/8" line set used for
5/8"
1/4"
Indoor
Unit
3/8"
1/4"
indoor unit
Indoor unit flare connection 1/4" X 5/8"
5K, 7K, 9K, 12K & 18K
3/8"
1/4"
3/8"
1/4"
Indoor
Unit
1/4" X 3/8" line set used for
5K, 7K, 9K, 12K & 18K
1/4" X 1/2" line set for 24K
12 or 18 kBtu/h
Indoor Unit
1/2"
5/8"
3/8"
1/2"
3/8"
1/2"
3/8"
(Outdoor
Connection
Port)
1/2"
Flare Nut
1/2"
(Indoor Connection Port)
3/8"
Flare Nut
CZ-MA1P-US-BUND
Line Set
Suction
Discharge
Outdoor Unit
2-Zone
3-Zone
4-Zone
5-Zone
Suction
Discharge
CZ-MA3P-US-BUND
24kBtu/h
Indoor Unit
5/8"
(Indoor Connection Port)
Flare Nut
1/2"
CZ-MA2P-US-BUND
Multi-Split Tube Adaptors
Tube Adaptors
Adaptor Chart
2 Zone
CU-2E18NBU
CU-2E18SBU-5
2-3 Zone
CU-3E19RBU-5
2-4 Zone
CU-4E24RBU-5
2-5 Zone
CU-5E36QBU-5
O/D
I/D
O/D
I/D
O/D
I/D
O/D
I/D
Wall Mount
CS-ME5RKUA
none
none
none
none
none
none
none
none
CS-ME7RKUA
none
none
none
none
none
none
none
none
CS-E9RKUAW
none
none
none
none
none
none
none
none
CS-E12RKUAW
none
(1) MA1P
none
(1) MA1P
none
(1) MA1P
none
(1) MA1P
CS-E18RKUAW
N/A
N/A
none
(1) MA1P
none
(1) MA1P
none
(1) MA1P
CS-E24RKUAW
N/A
N/A
N/A
N/A
(1) MA2P
(1) MA3P
(1) MA2P
(1) MA3P
4-Way
CS-ME9SB4U
none
none
none
none
none
none
none
none
CS-E12RB4UW
none
(1) MA1P
none
(1) MA1P
none
(1) MA1P
none
(1) MA1P
CS-E18RB4UW
N/A
N/A
N/A
(1) MA1P
none
(1) MA1P
none
(1) MA1P
Slim Duct
CS-ME5SD3UA
none
none
none
none
none
none
none
none
CS-ME7SD3UA
none
none
none
none
none
none
none
none
CS-E9SD3UAW
none
none
none
none
none
none
none
none
CS-E12SD3UAW
none
(1) MA1P
none
(1) MA1P
none
(1) MA1P
none
(1) MA1P
CS-E18SD3UAW
N/A
N/A
N/A
(1) MA1P
none
(1) MA1P
none
(1) MA1P
Adaptor Model
(male/female)
CZ-MA1P-US-BUND
3/8" M x 1/2"F
CZ-MA2P-US-BUND
3/8" F x 1/2"M
CZ-MA3P-US-BUND
1/2" M x 5/8"F
Flare Nut (included)
(Qty) and Adaptor Required for Multi Zone Installations
Model Number CU-5E36QBU-5
Note: Flare nut is usually supplied with all line sets.
Panasonic also provides flare nut with adaptor for contractor convenience.
Flare Nut
none - no adaptor required
N/A - indoor does not
match capacity of outdoor
Ducted Multi-Zone Applications Available March 2017.
47