General, Type of Copper Tube and Insulation Material
View all Panasonic CU-4KS31NBU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
1. General This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning. If the electric wiring diagram does not appear in this manual, please check for the diagram on the indoor unit. 1-1. Tools Required for Installation (not supplied) 1. Standard screwdriver 7. Hacksaw 2. Phillips head screwdriver 8. Core bits 3. Knife or wire stripper 9. Hammer 4. Tape measure 10. Drill 5. Carpenter's level 11. Tube cutter 6. Sabre saw or key hole saw 12. Tube flaring tool 13. Torque wrench 14. Adjustable wrench 15. Reamer (for deburring) 16. Vacuum pump (For R410A) 17. Manifold valve 1-2. Accessories Supplied with Unit Table 1 Parts Figure Q'ty Parts Labels for inter-unit cable and tube ABCD 4 each Cushion rubber Reducer (3/8" 1/2") CU-3KS19NBU 1 Figure Q'ty Parts 4 Reducer (1/2" 3/8") Figure Q'ty CU-4KS24NBU 1 CU-4KS31NBU 2 Packed in the outdoor unit. 1-3. Optional Copper Tubing Kit Copper tubing for connecting the outdoor unit to the indoor unit is available in kits which contain the narrow and wide tubing, fittings and insulation. Consult your nearest sales outlet or air conditioning workshop. 1-4. Type of Copper Tube and Insulation Material If you wish to purchase these materials separately from a local source, you will need: 1. Deoxidized annealed copper tube for refrigerant tubing as detailed in Table 2. Cut each tube to the appropriate lengths 1' to 1'4" (30 cm to 40 cm) to dampen vibration between units. 2. Foamed polyethylene insulation for the specified copper tubes as required to precise length of tubing. Wall thickness of the insulation should be not less than 5/16" (8 mm). 3. Use insulated copper wire for field wiring. Wire size varies with the total length of wiring. Refer to 5. Wiring Instructions for details. CAUTION Check local electrical codes and regulations before obtaining wire. Also, check any specified instructions or limitations. Table 2 Model CS-MKS7NKU, CS-MKS9NKU, CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU CS-MKS9NB4U, CS-MKS12NB4U CS-KS18NB4UW Narrow Tube Outer Dia. Thickness 1/4" (6.35 mm) 0.0314" (0.8 mm) 1/4" (6.35 mm) 0.0314" (0.8 mm) 1/4" (6.35 mm) 0.0314" (0.8 mm) 1/4" (6.35 mm) 0.0314" (0.8 mm) 1/4" (6.35 mm) 0.0314" (0.8 mm) Wide Tube Outer Dia. Thickness 3/8" (9.52 mm) 0.0314" (0.8 mm) 1/2" (12.70 mm) 0.0314" (0.8 mm) 5/8" (15.88 mm) 0.0393" (1.0 mm) 3/8" (9.52 mm) 0.0314" (0.8 mm) 1/2" (12.70 mm) 0.0314" (0.8 mm) 1-5. Additional Materials Required for Installation 1. Refrigeration (armored) tape 2. Insulated staples or clamps for connecting wire (See local codes.) 3. Putty 4. Refrigeration lubricant 5. Clamps or saddles to secure refrigerant tubing 4