List of components FV-08WQ1 Part name Drawing Wall sleeve Screw I (4 x 30) Quantity Part name Screw III (4 x 8) 1 Template (Pattern paper) 4 Mounting plate Exterior hood 1 Screw II (4 x 6) (for new construction only) 2 Externsion sleeve Drawing Quantity 1 1 1 1 Description This Panasonic wall mounted ventilating fan uses a propeller fan driven by a capacitor motor. The motor is designed for extended service life with reduced energy consumption. It also incorporates a thermal-cutoff device for safety. The grille is easily detachable from the main unit. Reference installation drawing Wall thickness: 114.3 - 152.4 mm (4.5 - 6") No extension sleeve is used. When the wall thickness is between 152.4 mm (6") and 254 mm (10"), mount the extension sleeve as shown below. When the wall thickness is more than 254 mm (10"), prepare an extension sleeve with an inner diameter of 207 mm (8 5/32") and a length of wall thickness minus 127 mm (5"), and mount it as shown below. (The seam should be covered with aluminum tape.) Exterior wall Flexible conduit Interior wall Junction box Connector Exterior wall Flexible conduit Extension sleeve Interior wall Junction box Connector Exterior hood Exterior hood Outdoor Wall sleeve Wall thickness Main unit Indoor Outdoor 2 Wall sleeve Wall thickness Main unit Indoor

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Wall
thickness
Exterior wall
Exterior
hood
Outdoor
Flexible
conduit
Wall sleeve
Junction box
Connector
Main unit
Indoor
2
Part name
Drawing
Screw
III
(4 x 8)
Template (Pattern paper)
Exterior hood
Externsion sleeve
Wall
thickness
Interior wall
Junction box
FV-08WQ1
Part name
Drawing
Wall sleeve
Screw
I
(4 x 30)
Mounting plate
Screw
II
(4 x 6) (for new
construction only)
List of components
Reference installation drawing
Description
This Panasonic wall mounted ventilating fan uses a propeller fan driven by a capacitor motor.
The motor is designed for extended service life with reduced energy consumption.
It also incorporates a thermal-cutoff device for safety.
The grille is easily detachable from the main unit.
Interior wall
Wall thickness:
114.3 - 152.4 mm (4.5 - 6")
No extension sleeve is used.
Quantity
1
4
1
2
Quantity
1
1
1
1
Exterior wall
Exterior
hood
Outdoor
Flexible conduit
Wall sleeve
Connector
Main unit
Indoor
When the wall thickness is between 152.4 mm (6") and 254 mm (10"), mount the extension
sleeve as shown below. When the wall thickness is more than 254 mm (10"), prepare an
extension sleeve with an inner diameter of 207 mm (8 5/32") and a length of wall thickness
minus 127 mm (5"), and mount it as shown below. (The seam should be covered with
aluminum tape.)
Extension
sleeve