Care and Replacement Replacing the lamp unit J Before replacing the lamp unit Switch off the MAIN POWER button in proper way and disconnect the power plug from the wall outlet. Make sure the lamp unit and the surroundings are cooled enough. Unplug all the cables from the projector. Prepare a Phillips-head screwdriver. Contact an Authorized Service Center to purchase a replacement lamp unit (ET-LAX100). When the projector is mounted in the ceiling, do not work directly under the projector or put your face closer to the projector. NOTE: • Prior to replacing the lamp unit, allow it to cool down to prevent the risk of burns, damage and other hazards. • Do not attempt replacement with an unauthorized lamp unit. J When to replace the lamp unit The lamp unit is consumable and the brightness decreases by duration of usage. The LAMP indicator will inform you of the replacement timing at 1 800 hours, and at 2 000 hours, the projector will be turned off. Those figures are rough guidance and might be shortened by the usage conditions, characteristics of the lamp unit, environmental conditions, and so on. You can check the duration of usage time using LAMP RUNTIME in the OPTION menu. On screen LAMP indicator Indication REPLACE LAMP Over 1 800 hours Over 2 000 hours "REPLACE LAMP" is displayed on the upper left of the screen for 30 seconds. To clear the screen immediately, press any button. Illuminates red. "REPLACE LAMP" is displayed on the upper left of the screen, and it will stay until you respond. To clear the screen, press any button. NOTE: • The guide times, 1 800 and 2 000 hours, are rough estimates based on certain conditions and is not a guaranteed time. The estimated condition is: LAMP POWER in OPTION menu set to NORMAL. • To prolong the lamp life, set the LAMP POWER in OPTION menu to ECO-MODE. See "LAMP POWER" on page 39. • For more information about the lamp unit, such as guaranteed time, see the instructions which is provided with the lamp unit. Maintenance 42 - ENGLISH

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Maintenance
Care and Replacement
42 -
E
NGLISH
Before replacing the lamp unit
Switch off the
MAIN POWER
button in proper way and disconnect the power plug from the wall outlet.
Make sure the lamp unit and the surroundings are cooled enough.
Unplug all the cables from the projector.
Prepare a Phillips-head screwdriver.
Contact an Authorized Service Center to purchase a replacement lamp unit (ET-LAX100).
When the projector is mounted in the ceiling, do not work directly under the projector or put your face closer to the
projector.
When to replace the lamp unit
The lamp unit is consumable and the brightness decreases by duration of usage. The
LAMP
indicator will
inform you of the replacement timing at 1 800 hours, and at 2 000 hours, the projector will be turned off. Those
figures are rough guidance and might be shortened by the usage conditions, characteristics of the lamp unit,
environmental conditions, and so on. You can check the duration of usage time using
LAMP RUNTIME
in the
OPTION
menu.
Replacing the lamp unit
NOTE:
Prior to replacing the lamp unit, allow it to cool down to prevent the risk of burns, damage and other hazards.
Do not attempt replacement with an unauthorized lamp unit.
Indication
On screen
LAMP
indicator
Over 1 800 hours
REPLACE LAMP
” is displayed on the upper left
of the screen for 30 seconds.
To clear the screen immediately, press any
button.
Illuminates red.
Over 2 000 hours
REPLACE LAMP
” is displayed on the upper left
of the screen, and it will stay until you respond.
To clear the screen, press any button.
NOTE:
The guide times, 1 800 and 2 000 hours, are rough estimates based on certain conditions and is not a guaranteed time.
The estimated condition is:
LAMP POWER
in
OPTION
menu set to
NORMAL
.
To prolong the lamp life, set the
LAMP POWER
in
OPTION
menu to
ECO-MODE
. See “LAMP POWER” on page 39.
For more information about the lamp unit, such as guaranteed time, see the instructions which is provided with the lamp
unit.
REPLACE LAMP