Panasonic WV-SFV781L Installation Guide - Page 2
Installation
View all Panasonic WV-SFV781L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
The installation tasks are explained using 3 steps. Step1 Fixing the brackets Installation Step2 Mount the camera to the attachment plate Step3 Adjustment Step1 Fixing the brackets [1] IMPORTANT: ●● Procure 4 screws (M4) to secure the A attachment plate (accessory) or B base bracket (accessory) to a ceiling or a wall. ●● When mounting the camera on a concrete ceiling, use an AY plug bolt (M4) for securing. (Recommended tightening torque: 1.6 N·m {1.18 lbf·ft}) ●● Select screws according to the material of the ceiling or wall that the camera will be mounted to. In this case, wood screws and nails should not be used. ●● If a ceiling board such as plaster board is too weak to support the total weight, the area shall be sufficiently reinforced. ●● If open wiring is conducted, be sure to use conduits and run the cables inside the conduit to protect the cables from direct sunlight. ●● Installation work shall be such that there is no exposure to water into the architecture through the conduits having been joined. [1] Mount the camera to a ceiling or a wall using base bracket The B base bracket (accessory) can be fixed in any of the following 5 screwing positions according to ceiling and wall conditions. Match the hole used when installing the camera to any of positions A to F. Position A 85 mm {3-11/32 inches} (85.7 mm {3-3/8 inches}) Position B Position C 46 mm {1-13/16 inches} 85 mm {3-11/32 inches} (85.7 mm {3-3/8 inches}) ø25.4 mm {ø1 inch}*1 138 mm {5-7/16 inches} ø25.4 mm {ø1 inch}*1 138 mm {5-7/16 inches} 83.5 mm {3-9/32 inches} ø25.4 mm {ø1 inch}*1 Position D 63 mm {2-15/32 inches} Position E*2 63 mm {2-15/32 inches} ø25.4 mm {ø1 inch}*1 Position F 108.5 mm {4-9/32 inches} 70 mm {2-3/4 inches} ø25.4 mm {ø1 inch}*1 *1 The wiring hole diameter is 25.4 mm {1 inch}. Select any of the 2 base bracket fixture holes of E template B (for the base bracket, accessory) when installing the base bracket. *2 When installing the WV-SFV781L, do not use Position E. ☞ For safety, a safety wire must be secured to a wall or ceiling. Refer to the "Securing a safety wire" leaflet for further information. ●● Mount the B base bracket (accessory) to a ceiling or wall using 4 fixing screws (M4, locally procured). Refer to the installation example on the right and pass the wiring through the base bracket. ●● Secure A attachment plate (accessory) to base bracket using 4 C attachment fixing screws (accessory). (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}) Fixing screws (M4 x 4, locally procured) Minimum pull-out strength: 539 N {121 lbf} (per 1 pc.) A Attachment plate (accessory) C Fixing screws for attachment plate: x 4 (accessory) (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}) B Base bracket (accessory) ARemove the cap for the female thread for the conduit by using a hexagon wrench (ISO 2936, width across flats S=5 mm {3/16 inches}). The female thread for conduit is compliant with ANSI NPSM (parallel pipe threads) 3/4 inches or G3/4 of ISO 228-1. * When making holes and wiring Cap for the female from a ceiling or wall, do not thread for the remove the cap for the female conduit thread for the conduit. BAttach the base bracket and attachment plate to a ceiling or wall. ●● Mount the base bracket to a ceiling or wall using 4 fixing screws (M4, locally procured). Refer to the installation example on the right and pass the wiring B Base bracket (accessory) through the base bracket. ●● Secure attachment plate to base bracket using 4 attachment fixing screws. (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}) Conduit B Base bracket (accessory) Fixing screws (M4 x 4, locally procured) Minimum pull-out strength: 539 N {121 lbf} (per 1 pc.) C F ixing screws for attachment plate: x 4 (accessory) (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}) A Attachment plate (accessory) When installing using an attachment plate, refer to "A Fixing the brackets [2][3]" in the bottom right of this page. Step2 Mount the camera to the attachment plate ACheck the position of attachment mounting screws on the bottom side of the camera. Attachment mounting screws x 4 BF ollow the instructions in "Making connections" to connect cables to the camera, then carry out waterproof treatment referring to "Waterproof Treatment for the Cable Joint Sections". CAlign the 4 attachment mounting screws at the bottom of the camera with the holes in the A attachment plate (accessory), and mount the camera. You can adjust the mounting direction of the camera in 90° increments. Make sure to hold both the camera body and protection cover when attaching the camera to the bracket. Rotate the camera approximately 15° so that Protruding part (4 locations) the LOCK mark is aligned with the protruding part. Dehumidifying device Wiring port A A ttachment plate (accessory) holes x 4 Camera body OPEN DLoosen the 2 dome fixing screws and remove the L Protection cover (accessory) from the camera with it still attached to the dome cover. * The dome cover is temporarily fixed to the camera using 2 dome fixing screws at factory shipment. The temporarily fixed dome fixing screws are the screws not attached to the protection cover auxiliary part. ERemove the protective packaging and fixing tape from the camera body. Auxiliary wire FSecure the camera using the camera fixing screws. (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}) IMPORTANT: ●● Securely tighten the camera fixing screws. Failure to observe this may cause the camera to fall or water to seep in, which may cause a personal injury or damage the camera. Camera fixing screw ■Image of the camera inserted into the attachment plate Hook part (A Attachment plate (accessory)) Protruding part (B Base bracket (accessory)) L P rotection cover (accessory) When attaching the attachment plate directly to a ceiling or wall When using the base bracket L Protection cover (accessory) Note: ●● After connecting the cables to the camera, align the OPEN mark on the camera body side panel with the protruding part of the B base bracket (accessory), insert 4 attachment mounting screws into the attachment plate, rotate the camera approximately 15° clockwise when looking up at it as illustrated, and move the LOCK mark toward the protruding part of the base bracket to temporarily secure the camera. (When directly mounting the attachment plate to a ceiling or wall, align the OPEN mark with the hook on the attachment plate.) Dome setscrew x 2 (The second screw is placed at the opposing side of this screw.) Note: ●● Loosen the 2 dome fixing screws using the F bit (accessory). * The camera connection cables, protection cover, dome cover and IR LED cables are omitted in subsequent illustrations. IMPORTANT: ●● Disconnect the 12 V DC power source and PoE power source to prevent power from being supplied during mounting work. ●● The dome cover protected by the L Protection cover (accessory) is connected to the cam- era body using the auxiliary wire. Do not disconnect it. ●● For installations on the wall, to prevent water from accumulating on the surface of the dehumidifying device, install the camera so that the dehumidifying device does not face up. If water accumulates on the surface of the dehumidifying device, it cannot function properly. Step3 Adjustment AHook a finger on either one of the 2 projections (parts shown by the arrow below) at the head of the camera and open the IR LED mounting section of the camera. ●● When opening the IR LED mounting section, be careful not to touch the lightblocking rubber, IR LED cover, or camera lens section. Fingerprints, etc. may cause the image quality to deteriorate. ●● The IR LED mounting section can be temporarily secured by opening it to its fullest extent. BConnect the monitor for adjustment to the MONITOR OUT terminal with an RCA pin cable (locally procured). ●● The NTSC monitor for adjustment can be connected in the default settings of the camera. CTurn on the camera. Make sure that the LINK indicator lights up orange, and the ACT indicator is blinking green. (Refer to the descriptions in "Major operating controls" for more information about the indicators.) DWhen using the SD memory card, follow the procedure below to mount it. ●● Turn the label side of the SD memory card to face the lens side of the camera, and line it up with the SD memory card insertion slot. ●● Insert the SD memory card into the socket, and push it in until a click sound is heard. MONITOR OUT Projection SD memory card insertion slot IR LED cover SD memory card Projection IR LED mounting section Light-blocking rubber ring IR LED mounting section Note: ●● To remove the SD memory card, hold down the SD ON/OFF button for about 2 seconds. When the flashing SD MOUNT indicator goes out, you can remove the SD memory card. ●● When the replacement of the SD memory card is complete, press the SD ON/OFF button (for 1 second or less), and check that the SD MOUNT indicator lights up. ●● If you do not press the SD ON/OFF button after replacing the SD memory card, the SD MOUNT indicator is automatically lit approximately 5 minutes later. ELoosen the pan table fixing screw, tilt table fixing screw, and yaw fixing screw to adjust the angle of the camera, and then adjust the viewing angle by pressing the WIDE or TELE button. Pan angle: ±180° Tilt angle: 0 to 85° Yaw angle: -45° (left) to +300° (right) ●● After completing the adjustment, process the IR LED cable using the hook for wiring processing (A) or (C). Do not remove the IR LED cable from the hook for wiring processing (B) when adjusting the yaw angle. FAfter adjusting the viewing angle, tighten each fixing screw. ●● Pan table fixing screw (Recommended tightening torque: 0.59 N·m {0.44 lbf·ft}) ●● Tilt table fixing screw (Recommended tightening torque: 0.59 N·m {0.44 lbf·ft}) ●● Yaw fixing screw should be tighten firmly by hand. GDisconnect the monitor for adjustment from the MONITOR OUT terminal and finally close the IR LED mounting section. Pan table fixing screw Pan angle TELE button WIDE button Tilt table fixing screw Hook for wiring processing (A) Hook for wiring processing (B) Yaw angle TOP mark Yaw angle IR LED mounting section Tilt angle Yaw fixing screw Hook for wiring processing (C) IR LED cable Note: ●● When the screen size is adjusted using the WIDE TELE button, the camera's focus is automatically adjusted with the basic focus adjustment function each time the WIDE button or TELE button is pressed. ●● Note that the camera silhouette appears depending on the adjustable angle or zoom ratio. ●● When mounting the camera, adjust the pan, tilt, and yaw angles so that the TOP mark of the lens always comes to the top side. ●● When the camera is installed on a wall, the image is rotated 180° upside down in the default settings. To correct the way the image is displayed, rotate the PAN angle 180° clockwise, or select "On" for "Upside-down" from the setup menu. Refer to the "Operating Instructions" (included in the CD-ROM) for information on how to set "Upside-down" in the setup menu. ●● Take care so that the IR LED cable does not get caught when closing the IR LED mounting section. ●● The pan table fixing screw, tilt table fixing screw, and yaw fixing screw may fall off if they are loosened excessively. ●● When using the camera at a position where the camera lens is nearly horizontal, part of an image may appear to be overlapped. In this case, decrease the vertical position angle or adjust the zoom ratio. HAttach the dome cover protected by IPull the 2 hooks of the protection the L protection cover (accessory) cover auxiliary part outward at the to the camera again, and fix it using same time, and remove the protection the 2 dome fixing screws shown in cover. illustration below. JSecure with the 2 dome fixing screws (Recommended tightening torque: shown in illustration below. (Secure 1.37 N·m {1.01 lbf·ft}) When attaching the dome cover protected by the protection cover, insert the extra part of the installation auxiliary the dome cover with 4 screws.) (Recommended tightening torque: 1.37 N·m {1.01 lbf·ft}) wire into the processing groove. The 3rd dome setscrew Auxiliary wire (the 4th screw is placed at the opposing side of this screw.) Hook of protection cover auxiliary part (There is one more on the opposite side.) Auxiliary wire Processing groove L P rotection cover (accessory) The 1st dome setscrew (the 2nd screw is placed at the opposing side of this screw.) Protection cover auxiliary part IMPORTANT: ●● When attaching the dome cover, process the wiring so that the installation auxiliary wire does not get caught. If the wire does get caught, the waterproofing performance may be compromised. ●● Securely tighten the 4 dome fixing screws. Failure to do so may cause the camera to drop. Recommended tightening torque: 1.37 N·m {1.01 lbf·ft} ●● After removing the L Protection cover (accessory), take care not to touch the surface of the dome cover. ●● When the dome cover is attached, the camera may go out of focus. After attaching the dome cover, start the auto focus function from the setup menu. Note: ●● When removing the camera, perform removal by above the installation procedure in the reverse order. ●● After installation has been completed, store the L Protection cover (accessory) to be used during servicing. When servicing the camera, remove the packing (2 pcs.) from the protection cover. A Fixing the brackets [2][3] [2] Using a two-gang junction box 46 mm {1-13/16 inches} Two-gang junction 83.5 mm {3-9/32 inches} A Attachment plate (accessory) Fixing screws (M4, locally procured) [3] Directly attach the attachment bracket to the ceiling or wall Attachment plate hook (4 places) 46 mm {1-13/16 inches} ø25.4 mm {1 inch}*3 83.5 mm {3-9/32 inches} ø73 mm {2-7/8 inches}*4 FRONT A Attachment plate (accessory) Fixing screws (M4, locally procured) *3 When the camera attachment direction has been determined before installation Match the FRONT direction (the direction of the FRONT direction marker when the camera is installed) of D template A to the direction you want the camera to face and open a ø25.4 mm (1 inch) hole before starting the installation. Install the camera with the Panasonic logo of the camera facing the FRONT direction of template A. *4 When the camera attachment direction has not been determined before installation or when changing the camera direction after installation To change the direction the camera faces, open a ø73 mm (2-7/8 inches) hole. The camera mounting direction can be changed in 90° increments. Information on installing or adjusting the camera is continued from Step 2. After installing the camera, refer to "Configure the settings of the camera" (leaflet) and perform the camera settings.