Pentair Boost-Rite Booster Pressure-Side Cleaner Pool Pump Boost-Rite Booster - Page 11

Page 11 highlights

7 OPERATION DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking. If this occurs, the damaged seal must be replaced. ALWAYS maintain proper water level in your pool. Continued operation in this manner could cause a loss of pressure, resulting in damage to the pump case, impeller and seal. Filter operates under high pressure. When any part of the circulating system (e.g., Lock Ring, Pump, Filter, Valves, etc.) is serviced, air can enter the system and become pressurized. Pressurized air can cause the filter lid to separate which can result in severe injury, death, or property damage resulting in damage to the pump case, impeller and seal, and may cause property damage and personal injury. To avoid this potential hazard, follow these instructions. Preparation for Operation Since the filter operates under high pressure, it is important to relieve any pressurized air before performing any maintenance or servicing. Follow the instructions below to relieve pressure from the filtration system. 1. Stop pump, close valves on suction and discharge lines, and release all pressure from system before proceeding. 2. Open the manual air relief valve on top of the filter. 3. Open the suction side valve to release any trapped air. Turn the filter pump on and stand clear of the filter. 4. Bleed air from the filter until a steady stream of water comes out. 5. Close the manual air relief valve. Starting the Pump For startup, be sure the filter pump is running and an automatic pool cleaner is connected before starting the booster pump. The booster pump must have a water flow of at least 20 GPM from the filtration system to avoid running the pump dry. 1. Start the filter pump at least 30 minutes before starting the booster pump to ensure pump is primed. 2. Be sure all valves are open before starting the booster pump. Shutoff valves can be located between the filter pump and filter or between the filter pump and pool. 3. Open all filtration valves to allow enough water for the booster pump during operation. 4. If there is a SVRS (Safety Vacuum Release System) for the filter and booster pumps, set SVRS to shut off both pumps. 5. Be sure the filter is clean and free of debris. A clogged filter reduces the water supply to the booster pump and can cause damage to the pump mechanical seal. Automatic Timer A separate automatic timer is recommended for the booster pump to ensure proper water flow from the filter to the booster pump. 1. Set the timer to start the filter pump at least 30 minutes before and stop 30 minutes after the booster pump. 2. Be sure your automatic pool cleaner is timed to run only for the length of time needed to clean the pool. Note: Operating the booster pump while the filter pump is off can damage the pump. 3. Reset the timers if power is shut off or interrupted. Check your system timers to be sure the filter pump starts before the booster pump. 4. A separate manual switch is recommended in addition to an automatic timer to turn the booster pump off if the filter system needs to be shut off for any reason. Example: Set Timer: Filter Pump Booster Pump Start 8:00 AM 8:30 AM Stop 2:00 PM 1:30 PM BOOST-RITE™ Universal Booster Pump Installation and User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

7
BOOST-RITE
Universal Booster Pump Installation and User’s Guide
Automatic Timer
A separate automatic timer is recommended
for the booster pump to ensure proper water
flow from the filter to the booster pump.
1.
Set the timer to start the filter pump at
least 30 minutes before and stop 30
minutes after the booster pump.
2.
Be sure your automatic pool cleaner is
timed to run only for the length of time
needed to clean the pool.
Note:
Operating the booster pump while
the filter pump is off can damage the pump.
3.
Reset the timers if power is shut off or
interrupted. Check your system timers to
be sure the filter pump starts before the
booster pump.
4.
A separate manual switch is recom-
mended in addition to an automatic
timer to turn the booster pump off if the
filter system needs to be shut off for any
reason.
Starting the Pump
For startup, be sure the filter pump is running
and an automatic pool cleaner is connected
before starting the booster pump. The booster
pump must have a water flow of at least 20
GPM from the filtration system to avoid running
the pump dry.
1. Start the filter pump at least 30 minutes
before starting the booster pump to ensure
pump is primed.
2.
Be sure all valves are open before starting
the booster pump. Shutoff valves can be
located between the filter pump and filter
or between the filter pump and pool.
3.
Open all filtration valves to allow enough
water for the booster pump during operation.
Preparation for Operation
Since the filter operates under high pressure, it
is important to relieve any pressurized air before
performing any maintenance or servicing.
Follow the instructions below to relieve pressure
from the filtration system.
1. Stop pump, close valves on suction and
discharge lines, and release all pressure
from system before proceeding.
2. Open the manual air relief valve on top
of the filter.
3. Open the suction side valve to release
any trapped air. Turn the filter pump on
and stand clear of the filter.
4. Bleed air from the filter until a steady
stream of water comes out.
5.
Close the manual air relief valve.
4.
If there is a SVRS (Safety Vacuum Release
System) for the filter and booster pumps,
set SVRS to shut off both pumps.
5.
Be sure the filter is clean and free of debris.
A clogged filter reduces the water supply to
the booster pump and can cause damage
to the pump mechanical seal.
OPERATION
DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start
leaking. If this occurs, the damaged seal must be replaced. ALWAYS maintain proper water level in your pool.
Continued operation in this manner could cause a loss of pressure, resulting in damage to the pump case,
impeller and seal.
Filter operates under high pressure. When any part of the circulating system (e.g., Lock Ring, Pump, Filter,
Valves, etc.) is serviced, air can enter the system and become pressurized. Pressurized air can cause the filter
lid to separate which can result in severe
injury, death, or property damage resulting in damage to the pump
case, impeller and seal, and may cause property damage and personal injury. To avoid this potential hazard,
follow these instructions.
Set Timer:
Start
Stop
Filter Pump
8:00 AM
2:00 PM
Booster Pump
8:30 AM
1:30 PM
Example: