Pentair IntelliCenter Control System IntelliCenter Upgrade Kit - Legacy System - Page 2
General Installation Information - pool light customer service
View all Pentair IntelliCenter Control System manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
ii EasyTouch/IntelliTouch Control System Legacy Upgrade Kits Installation Instructions CUSTOMER SERVICE / TECHNICAL SUPPORT Customer Service 8 AM to 5.30 PM - Eastern and Pacific Times Phone: (800) 831-7133 Fax: (800) 284-4151 Visit www.pentair.com Technical Support Sanford, North Carolina (8 A.M. to 8.30 PM ET) Phone: (919) 566-8000 Fax: (919) 566-8920 Moorpark, California (8 A.M. to 5.30 PM PT) Phone: (805) 553-5000 (Ext. 5591) Fax: (805) 553-5515 Contents IMPORTANT WARNING AND SAFETY INSTRUCTIONS ii-vi OVERVIEW / SUMMARY ...1-2 BOX CONTENTS ...3 REMOVING THE EXISTING OUTDOOR CONTROL PANEL 4 INSTALL THE NEW 4A AND 5A LOW VOLTAGE CIRCUIT BREAKERS BRACKET AND SYSTEM TRANSFORMER ...6 INSTALLING THE INTELLICENTER CONTROL SYSTEM OUTDOOR CONTROL PANEL ......... 8 CONNECTING AND CONFIGURING POOL AND SPA EQUIPMENT 9 INSTALLING THE WIRING LABEL ON THE ENCLOSURE FRONT DOOR 10 NOTE: INSTALLING THE HIGH POWER WIRELESS (HPW) KIT ANTENNA (see manual provided in HPW Link box) General Installation Information 1. All work must be performed by a licensed electrician, and must conform to all national, state, and local codes. 2. Install to provide drainage of compartment for electrical components. 3. If this system is used to control underwater lighting fixtures, a ground-fault interrupter (GFCI) must be provided for these fixtures. Conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, junction boxes or enclosures containing other conductors unless such conductors are also protected by a ground-fault circuit-interrupter. Refer to local codes for details. 4. A terminal bar stamped is located inside the supply terminal box. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying this equipment (no smaller than 12 AWG or 3.3 mm). The bonding lug(s) provided on this unit are intended to connect a minimum of one No. 8 AWG for US installation and two No. 6 AWG for Canadian installations solid copper conductor between this unit and any metal equipment, metal enclosures or electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit. 5. The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with in accordance with the current National Electrical Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local installation codes and ordinances must also be adhered to. The disconnecting means must be readily accessible to the tub occupant but installed at least 10 ft. (3.05 m) from the inside wall of the pool. 6. GAS HEATER: This automation control system is designed to supply high voltage (120 VAC / 240 VAC) to a gas heater and override the thermostat in the heater's control circuit. This automation control system is intended to control gas heaters with a high temperature limit switch(s) safety circuit. P/N 523472 Rev. C 10/2020 Note: Refer to page 3 where (parts index number) is shown