Connect the Stack Flu sensor. Fig. 10

Page 4 highlights

WIRE HARNESS REPLACEMENT INSTRUCTIONS (USA) 7. Install the bushing in the top of the control box. Use (Fig. 6) 10. Connect the Stack Flu sensor. (Fig. 10) FIG. 6. 8. Route the Red and Green wires into the Control Box through the bottom hole. Plug the Fireman's jumper into the terminal board. Install bushing. Note: The plugs are shown in the control box and the Fireman's jumper installed. (Fig. 7). FIG. 10. 11. Connect the Gas Valve. (Fig. 11). FIG. 7 9. If the heater has a legacy ICM, connect each wire from P/N 476204 wire adapter to its correct location labeled in the ICM. Otherwise, connect the multi-pin connector from the Wire Harness to lower right side of ICM as shown in Fig 8. FIG.11. 12. Connect the Blower assembly. (Fig. 12). FIG. 8. FIG.12. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

4
WIRE HARNESS REPLACEMENT INSTRUCTIONS (USA)
8.
Route the Red and Green wires into the Control Box
through the bottom hole. Plug the Fireman’s jumper into
the terminal board. Install bushing.
Note: The plugs
are shown in the control box and the Fireman’s jumper
installed. (Fig. 7).
9.
If the heater has a legacy ICM, connect each wire from
P/N 476204 wire adapter to its correct location labeled
in the ICM. Otherwise, connect the multi-pin connec-
tor from the Wire Harness to lower right side of ICM as
shown in Fig 8.
FIG. 8.
FIG. 7
7.
Install the bushing in the top of the control box. Use
(Fig. 6)
FIG. 6.
FIG.11.
10.
Connect the Stack Flu sensor. (Fig. 10)
FIG. 10.
11.
Connect the Gas Valve. (Fig. 11).
12.
Connect the Blower assembly. (Fig. 12).
FIG.12.