Pentax 01459 ZX-60 Manual - Page 40

Built-in, Flash

Page 40 highlights

a 'USING r' , AILT- DEMIMONDES& THE BUILT-IN FLASH Auto-popup flash function Selecting the various built-in flash modes In this mode, the built-in flash pops up and discharges automatically in low light and backlight condition. At each depress of the flash 1 6 Depress the flash mode button until MI appears on the LCD panel. T o-7i)FF 01A 8 1 C21TvAvM AUTO Tv`-- Av 125 8.0 2 11 J Depress the shutter release button halfway down, and mode button, the flash mode on the LCD panel changes as shown in the chart. caio MODE DATE I I AUTO 's AUTO I♦ I® • I ® Auto-popup Auto-popup Manual-popup Manual-popup Flash off (See page 80) (See page 83) Red-eye reduction Red eye reduction the built-in flash (See page 78. 80) automatically pops up when the flash is required. MEMO • The built-in flash does not retract automatically, push the built-in flash down into the camera body after use. • The built-in flash does not discharge when not required even though it has been in the up position. • Do not use the lens hood when the built-in flash is used, as it may obstruct the path of the light coming from the flash, causing vignetting in the picture corners. • When using an inappropriate F or FA lens, T will blink rapidly in the viewfinder and on the LCD panel when the shutter release button is depressed halfway down. For more details on COMPATIBILITY OF F AND FA LENSES WITH THE BUILT-IN FLASH, see page 88. • If the built-in flash is used continuously, the battery may become warm, but it does not mean that the battery is faulty; it's one of the battery's characteristics. 136211 • o MEMO • The auto-popup flash mode can only be set when one of 6 picture modes is selected. • The built-in flash pops up automatically when VEM is displayed on the LCD panel. However, it discharges only when required. (Automatic flash function) or !_g_pi can only be set when one of 6 picture modes is selected. • The auto-popup function of the built-in flash does not work when the AE lock function is in use. • The automatic flash function can also be used with the external flash. • Even if MO is displayed on the LCD panel, the built-in flash does not pop up automatically when the external flash has been mounted either with the power off or the external flash is not yet fully charged. • If the red-eye reduction is used while the AF360 FGZ, etc. is set as a slave unit, the pre-flash will trigger the slave unit to discharge. Do not use red-eye reduction with slave unit. • The shutter cannot be released until the flash is fully charged. • . .

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

a
r'
,
AILT
-
DEMIMONDES&
'USING
THE
BUILT-IN
FLASH
Auto-popup
flash
function
In
this
mode,
the
built-in
flash
pops
up
and
discharges
automatically
in
low
light
and
backlight
condition.
1
Depress
the
flash
mode
button
until
MI
appears
on
the
LCD
panel.
oi
T
-
7)FF
01A
8
1
C
2
1TvAvM
AUTO
Tv`--
Av
125
8.0
2
Depress
the
shutter
release
button
halfway
down,
and
the
built-in
flash
automatically
pops
up
when
the
flash
is
required.
11
MEMO
The
built-in
flash
does
not
retract
automatically,
push
the
built-in
flash
down
into
the
camera
body
after
use.
The
built-in
flash
does
not
discharge
when
not
required
even
though
it
has
been
in
the
up
position.
Do
not
use
the
lens
hood
when
the
built-in
flash
is
used,
as
it
may
obstruct
the
path
of
the
light
coming
from
the
flash,
causing
vignetting
in
the
picture
corners.
When
using
an
inappropriate
F
or
FA
lens,
T
will
blink
rapidly
in
the
viewfinder
and
on
the
LCD
panel
when
the
shutter
release
button
is
depressed
halfway
down.
For
more
details
on
COMPATIBILITY
OF
F
AND
FA
LENSES
WITH
THE
BUILT-IN
FLASH,
see
page
88.
If
the
built-in
flash
is
used
continuously,
the
battery
may
become
warm,
but
it
does
not
mean
that
the
battery
is
faulty;
it's
one
of
the
battery's
characteristics.
The
shutter
cannot
be
released
until
the
flash
is
fully
charged.
.
.
Selecting
the
various
built-in
flash
modes
At
each
depress
of
the
flash
mode
button,
the
flash
mode
on
the
LCD
panel
changes
as
shown
in
the
chart.
6
caio
MODE
DATE
AUTO
I
I
I
Auto-popup
Auto-popup
Manual-popup
Manual-popup
Flash
off
(See
page
80)
Red
-eye
reduction
's
AUTO
®
I
J
(See
page
83)
Red
eye
reduction
(See
page
78.
80)
o
MEMO
The
auto-popup
flash
mode
can
only
be
set
when
one
of
6
picture
modes
is
selected.
The
built-in
flash
pops
up
automatically
when
VEM
is
displayed
on
the
LCD
panel.
However,
it
discharges
only
when
required.
(Automatic
flash
function)
or
!_g_pi
can
only
be
set
when
one
of
6
picture
modes
is
selected.
The
auto-popup
function
of
the
built-in
flash
does
not
work
when
the
AE
lock
function
is
in
use.
The
automatic
flash
function
can
also
be
used
with
the
external
flash.
Even
if
MO
is
displayed
on
the
LCD
panel,
the
built-in
flash
does
not
pop
up
automatically
when
the
external
flash
has
been
mounted
either
with
the
power
off
or
the
external
flash
is
not
yet
fully
charged.
If
the
red
-eye
reduction
is
used
while
the
AF360
FGZ,
etc.
is
set
as
a
slave
unit,
the
pre
-flash
will
trigger
the
slave
unit
to
discharge.
Do
not
use
red
-eye
reduction
with
slave
unit.