ProForm Xp210 U Bike English Manual - Page 19
Maintenance And Troubleshooting
View all ProForm Xp210 U Bike manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
MAINTENANCE AND TROUBLESHOOTING Inspect and tighten all parts of the exercise bike regularly. Replace any worn parts immediately. Next, locate the Reed Switch (21). Loosen, but do not remove, the M4 x 16mm Screw (40). To clean the exercise bike, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid 13 damage to the console, keep liquids away from the console and keep the console out of direct sunlight. CONSOLE TROUBLESHOOTING If the console display becomes dim, replace all the batteries at the same time; most console problems are the result of low batteries. See assembly step 11 on page 10 for replacement instructions. If the console does not display your heart rate when you use the handgrip heart rate monitor, see step 5 on 16 page 15. HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. 40 21 Using a flat screwdriver, remove the Top Shield Cap (10). Then, remove the two M4 x 16mm Screws (40) and lift the Top Shield (9) away from the frame. Rotate the Pulley (13) until a Pulley Magnet (16) is aligned with the Reed Switch (21). Slide the Reed Switch slightly toward or away from the Pulley Magnet. Then, retighten the M4 x 16mm Screw (40). 40 9 10 Rotate the pulley for a moment. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, reattach the top shield and the top shield cap. 19