Maintenance And Troubleshooting
View all ProForm Xp440 R Bike manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
MAINTENANCE AND TROUBLESHOOTING Inspect and tighten all parts of the exercise bike regularly. Replace any worn parts immediately. Next, locate the Reed Switch (46). Loosen, but do not remove, the M4 x 16mm Screw (61). To clean the exercise bike, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. CONSOLE TROUBLESHOOTING If the console display becomes dim, replace all the batteries at the same time; most console problems are the result of low batteries. See assembly step 7 on page 8 for replacement instructions. If the console does not display your heart rate when you use the handgrip heart rate monitor, see step 5 on page 15. 43 61 46 44 Next, rotate the Pulley (43) until a Magnet (44) is aligned with the Reed Switch (46). Slide the Reed Switch slightly toward or away from the Magnet. Then, retighten the M4 x 16mm Screw (61). HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, you must first remove the 12 Shield Cover (12). Using a flat screwdriver, release the tabs on the Shield Cover, and then lift the Shield Cover away from the frame. Rotate the Pulley (43) for a moment. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, reattach the shield cover. 18