Pyle HTG158 Instruction Manual - Page 6
X-OVER, Low pass x-over frequency control, Bass BOOST, REMOTE, Warning, GREEN, Auxiliary outputs
View all Pyle HTG158 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
4. X-OVER • Full pass x-over switch When the switch is in the "Full" position, the full range is bypassed. • Low pass x-over switch When the switch is in the "LPF" position, frequencies lower than the low pass frequency setting are passed. The frequency can be adjusted between 50Hz and 250Hz. • High pass x-over switch When the switch is in the "HPF" position, frequencies higher than the high pass frequency setting are passed. 5. Low pass x-over frequency control This control is used to select the desired low pass x-over frequency. The frequency can be adjusted between 50Hz and 250Hz. 6. Bass BOOST The boost can be selected among 0dB, 6dB and 12dB. 7. REMOTE Controls the subwoofer ampli er gain, from a remote location for ease of adjustment during listening. Warning: Do not connect a level control knob from other manufacturers to the Remote Sub Level Control of any ampli er. Even though the connectors t properly, the control knob and connector pin positions may be di erent and the ampli er will be damaged. 8. LED Will illuminate GREEN to indicate the ampli er is on and operating normally, and will be illuminate RED if the ampli er shuts down due to short circuit, DC o set, or overheating detected by on board protection circuitry. 9. Auxiliary outputs The Auxiliary outputs o er LANZAR ampli ers easy, unlimited system expansion. Route RCA's from the line out of the rst ampli er to the line input of a second ampli er when using a single source output. 6 www.Lanzar.com