Site Safety, Operation Safety, Installation Safety, Introduction to Refrigerants R32, Please note

Page 11 highlights

Introduction to Refrigerants R32 1. Site Safety Open Flames Prohibited 2. Operation Safety Ventilation Necessary Mind Static Electricity 3. Installation Safety Refrigerant Leak Detector Appropriate Installation Location Must Wear Protective Clothing and anti-static gloves Don't use mobile phone The left picture is the schematic diagram of a refrigerant leak detector. Please note that: 1.The installation site should be in a well-ventilated condition. 2.The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding, smoking, drying oven or any other heat source higher than 548¥ which easily produces open fire. 3.When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear antistatic clothing and/or gloves. 4.It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible and/or explosive environment. 5.If the indoor unit suffers refrigerant leak during the installation, all the personnel should go out till the refrigerant leaks completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product back to the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other operations on the user's site. 6.It is necessary to choose the place where the inlet and outlet air of the indoor unit is even. 7.It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

1. Site Safety
2. Operation Safety
Don't use mobile phone
Mind Static Electricity
Open Flames Prohibited
Ventilation Necessary
Must Wear Protective Clothing and
anti-static gloves
3. Installation Safety
Refrigerant Leak Detector
The left picture is the schematic diagram of a refrigerant leak detector.
Appropriate Installation
Location
1.The installation site should be in a well-ventilated condition.
2.The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or
welding, smoking, drying oven or any other heat source higher than 548
which easily produces open fire.
3.When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-
static
clothing and/or gloves.
4.It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of
the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible
and/or explosive environment.
5.If the indoor unit suffers refrigerant leak during the installation, all the personnel should go out till the refrigerant
leaks completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product back to
the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other operations on the user's
site.
6.It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
7.It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets,
kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit.
10
Introduction to Refrigerants R32
Please note that: