Important Considerations Before installing the appliance, you must read the manual carefully to get the safety information and notes. Unit refrigerant charge amount: refer to unit name plate marking. A leak test must be done after the installation is completed. It is a must to do the safety inspection before maintaining or repairing an air conditioner using combustible refrigerant in order to ensure that the fire risk is reduced to minimum. It is necessary to operate the machine under a controlled procedure in order to ensure that any risk arising from the combustible gas or vapor during the operation is reduced to minimum. Introduction to Refrigerants R32(Only for R32 Model) 1. Site Safety Open Flames Prohibited 2. Operation Safety Open Flames Prohibited Ventilation Necessary Mind Static Electricity Must Wear Protective Clothing and anti-static gloves 3. Installation Safety Refrigerant Leak Detector Appropriate Installation Location Don't use mobile phone The left picture is the schematic diagram of a refrigerant leak detector. Please note that: 1. The installation site should be in a well-ventilated condition. 2. The sites for installing and maintaining an air conditioner using Refrigerant or welding, smoking, drying oven or any other heat source higher than 548 R3w2hsichhoueladsbiley fprreoedfurcoems ooppeenn ffiirree. 3. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-static clothing and/or gloves. 4. It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible and/or explosive environment. 5. If the indoor unit suffers refrigerant leak during the installation, all the personnel should go out till the refrigerant leaks completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product back to the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other operations on the user's site. 6. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even. 7. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit, and also prevent mechanical damage from occurring. 9