DATA SHEET MT 4 MULTICHANNEL TRANSFORMER MT 4 MULTICHANNEL TRANSFORMER General Description The MT 4 four-channel distribution transformer is packaged in a space saving 1U, 19-inch rack-mount tray. The fully isolated, high-performance toroid transformers provide flat frequency response within 1 dB from 40 Hz to 20 kHz. Each transformer is designed for an 8Ω 100 watt input, and 100 watt 70 volt or 100 watt 100 volt output. The recommended load for the 70 volt tap is 50 Ω. The recommended load for the 100 volt tap is 100 Ω. Convenient Euroblock connectors are provided on the rear of the chassis. The MT 4 comes ready-to-use with four mounted transformers and strain-relief Euro connectors. The tray with Euroblock connectors (model KT 4) and individual transformers with mounting hardware (model TF 4) are available separately, allowing the installer to build a tray with just the number of channels required. (see the mounting in Figure 4, next page). This makes this ideal for any rack system where high-performance 100 watt, 100 / 70 volt, isolated distribution transformers are required. For 25 volt audio distribution systems, the TF 4 can be used by connecting the 25V loads between its 70V and 100V taps (green and yellow wires). Thermal resistance of the TF 4 is only 1C/W and is lower when mounted in a MT 4 chassis. Other creative combinations are possible. For example, the yellow/green pair can drive 8Ω loads near to the amplifier, with the red/yellow pair being simultaneously used for a 70 V system. Depending on loading of the 70 V system, this arrangement presents an impedance between 4 and 8Ω to the amplifier. TF 4 can be used at power ratings much higher than 100 W, provided that the low-cut frequency is moved up accordingly. Since voltage capability doubles with each octave, power capability quadruples each octave. See the RaneNote "Constant-Voltage Audio Distribution Systems: 25, 70.7 & 100 Volts" available at rane.com. Features • Four channels, 100 watts, 100 / 70 volt • Input 8Ω, 100 watts • Euroblock strain-relief connectors • 1U, 19 inch rackmount tray • Frequency response 40 Hz to 20 kHz +0, -1 dB • Separate mounting tray and individual transformers available Options • MT 4 rackmount tray with four transformers (shown below) • KT 4 rackmount tray only • TF 4 individual transformers Data Sheet-1

  • 1
  • 2

Data Sheet-1
MT 4
MULTICHANNEL TRANSFORMER
Features
Four channels, 100 watts, 100 / 70 volt
Input 8Ω, 100 watts
Euroblock strain-relief connectors
1U, 19 inch rackmount tray
Frequency response 40 Hz to 20 kHz +0, -1 dB
Separate mounting tray and individual transformers available
Options
MT 4 rackmount tray with four transformers (shown below)
KT 4 rackmount tray only
TF 4 individual transformers
DATA SHEET
General Description
°e MT 4 four-channel distribution transformer is packaged in
a space saving 1U, 19-inch rack-mount tray. °e fully isolated,
high-performance toroid transformers provide flat frequency re-
sponse within 1 dB from 40 Hz to 20 kHz. Each transformer is
designed for an 8Ω 100 watt input, and 100 watt 70 volt or 100
watt 100 volt output. °e recommended load for the 70 volt tap
is 50 Ω. °e recommended load for the 100 volt tap is 100 Ω.
Convenient Euroblock connectors are provided on the rear of the
chassis.
°e MT 4 comes ready-to-use with four mounted transform-
ers and strain-relief Euro connectors. °e tray with Euroblock
connectors (model KT 4) and individual transformers with
mounting hardware (model TF 4) are available separately, allow-
ing the installer to build a tray with just the number of channels
required. (see the mounting in Figure 4, next page). °is makes
this ideal for any rack system where high-performance 100 watt,
100 / 70 volt, isolated distribution transformers are required.
For 25 volt audio distribution systems, the TF 4 can be used
by connecting the 25V loads between its 70V and 100V taps
(green and yellow wires). °ermal resistance of the TF 4 is only
1C/W and is lower when mounted in a MT 4 chassis.
Other creative combinations are possible. For example, the
yellow/green pair can drive 8Ω loads near to the amplifier, with
the red/yellow pair being simultaneously used for a 70 V system.
Depending on loading of the 70 V system, this arrangement
presents an impedance between 4 and 8Ω to the amplifier.
MT 4
MULTICHANNEL
TRANSFORMER
TF 4 can be used at power ratings much higher than 100 W,
provided that the low-cut frequency is moved up accordingly.
Since voltage capability doubles with each octave, power capabil-
ity quadruples each octave. See the RaneNote "
Constant-Voltage
Audio Distribution Systems: 25, 70.7 & 100 Volts
” available at
rane.com.