Rane ZR1 CP64S Data Sheet - Page 8

Rear Panel, Architectural Specifications, Available Accessories

Page 8 highlights

CP64S COMMERCIAL PROCESSOR Rear Panel Architectural Specifications The processor shall provide two fully independent gated paging inputs, three line-level non-priority program inputs and one gated line-level priority program input. Two zone outputs shall be served. Zone 1 shall be a stereo zone with balanced, crosscoupled outputs. Zone 2 shall be a mono zone with a balanced cross-coupled output. Mono expansion ports for page, program or zone signals shall be provided for each zone. Wired remote control ports shall be provided for paging zone assign, zone program select and zone level. Page inputs shall use a 5-pin Euroblock connector. Paging controls shall include: • 30 dB mic/line input pad. • Input gain trim range of 30 dB to 60 dB. • Mic gate threshold (range -∞ to +4 dBu). • 15 volt phantom power (internal switch). • Paging priority (page 1, none, page 2; internal switch). • Pre- or post-zone level summing (internal switch). • Front panel paging zone assign (Remote, Z1, Z2, Both). • Remote paging zone assign (Off, Z1, Z2, Both). • Paging zone level. Each Program input shall have stereo RCA input jacks and independent input level control. The priority program assign switch shall provide priority program override to zone 1, zone 2, both, or neither (off). The gated priority program input shall have internally adjustable threshold and release time controls. Zone outputs shall use 3-pin Euroblock connectors. Zone controls shall include: • Ducker on/off • Ducker depth (-6 to -50 dB) • Program select (L1, L2, L3, P) • Zone level • 7-band graphic equalizer (±12 dB) • Servo-Locked-Limiter™ threshold (-20 to +20 dBu) • Mono switch for Zone 1 (internal) • Remote engage switch Wired remote ports shall use 3-pin Euroblock connectors. Remote logic shall be active low with internal pull-up. Remote level control shall be ratiometric DC control with 5 volt reference. The unit shall be capable of operation by means of its own built-in universal power supply operating at 100-240 VAC and meet CE requirements. The unit shall be UL and cUL listed. The unit shall be entirely constructed from cold-rolled steel. Reliability and efficiency are to be primary design considerations. The unit shall be a Rane Corporation CP64S Commercial Processor. Available Accessories • SCP2S Security Cover (for EQ section) • SC 1.7 Security Cover (for entire front panel) • PR2 Page Assign Remote Control • ZR1 Zone Source/Volume Remote Control • VR1 Volume Remote Control • Hole Plugs (6 Provided with SCP2S) ©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5000 USA TEL 425-355-6000 FAX 425-347-7757 WEB rane.com Data Sheet-8 All features & specifications subject to change without notice. 1-2014

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Data Sheet-8
CP64S
COMMERCIAL PROCESSOR
©Rane Corporation
10802 47th Ave. W.,
Mukilteo WA 98275-5000 USA
TEL 425-355-6000
FAX 425-347-7757
WEB rane.com
CP64S
COMMERCIAL PROCESSOR
Rear Panel
All features & specifications subject to change without notice. 1-2014
Architectural Specifications
°e processor shall provide two fully independent gated paging
inputs, three line-level non-priority program inputs and one
gated line-level priority program input. Two zone outputs shall
be served. Zone 1 shall be a stereo zone with balanced, cross-
coupled outputs. Zone 2 shall be a mono zone with a balanced
cross-coupled output. Mono expansion ports for page, program
or zone signals shall be provided for each zone. Wired remote
control ports shall be provided for paging zone assign, zone
program select and zone level.
Page inputs shall use a 5-pin Euroblock connector. Paging
controls shall include:
• 30 dB mic/line input pad.
• Input gain trim range of 30 dB to 60 dB.
• Mic gate threshold (range -
to +4 dBu).
• 15 volt phantom power (internal switch).
• Paging priority (page 1, none, page 2; internal switch).
• Pre- or post-zone level summing (internal switch).
• Front panel paging zone assign (Remote, Z1, Z2, Both).
• Remote paging zone assign (Off, Z1, Z2, Both).
• Paging zone level.
Each Program input shall have stereo RCA input jacks and
independent input level control. °e priority program assign
switch shall provide priority program override to zone 1, zone 2,
both, or neither (off). °e gated priority program input shall
have internally adjustable threshold and release time controls.
Zone outputs shall use 3-pin Euroblock connectors. Zone
controls shall include:
• Ducker on/off
• Ducker depth (-6 to -50 dB)
• Program select (L1, L2, L3, P)
• Zone level
• 7-band graphic equalizer (±12 dB)
• Servo-Locked-Limiter
threshold (-20 to +20 dBu)
• Mono switch for Zone 1 (internal)
• Remote engage switch
Wired remote ports shall use 3-pin Euroblock connectors.
Remote logic shall be active low with internal pull-up. Remote
level control shall be ratiometric DC control with 5 volt
reference.
°e unit shall be capable of operation by means of its own
built-in universal power supply operating at 100-240 VAC and
meet CE requirements. °e unit shall be UL and cUL listed. °e
unit shall be entirely constructed from cold-rolled steel.
Reliability and efficiency are to be primary design consider-
ations.
°e unit shall be a Rane Corporation CP64S Commercial
Processor.
Available Accessories
SCP2S Security Cover (for EQ section)
SC 1.7 Security Cover (for entire front panel)
PR2 Page Assign Remote Control
ZR1 Zone Source/Volume Remote Control
VR1 Volume Remote Control
Hole Plugs (6 Provided with SCP2S)