RedMax BCZ2460TS Owners Manual - Page 20
Troubleshooting, Case 1. Starting failure, CHECK, PROBABLE CAUSES, ACTION
View all RedMax BCZ2460TS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
BCZ2460S/TS 13. Troubleshooting guide Case 1. Starting failure CHECK fuel tank fuel filter carburetor adjustment screw sparking (no spark) spark plug PROBABLE CAUSES ➞ incorrect fuel ➞ fuel filter is clogged ➞ out of normal range ➞ spark plug is fouled/wet ➞ plug gap is incorrect ➞ disconnected ACTION ➞ drain it and with correct fuel ➞ clean ➞ adjust to normal range ➞ clean/dry ➞ correct (GAP: 0.6 - 0.7 mm) ➞ retighten Case 2. Engine starts but does not keep running/Hard re-starting. CHECK PROBABLE CAUSES fuel tank ➞ incorrect fuel or staled fuel ➞ carburetor adjustment screw ➞ out of normal range ➞ muffler,cylinder (exhaust port) ➞ carbon is built-up ➞ air cleaner ➞ clogged with dust ➞ cylinder fin, fan cover ➞ clogged with dust ➞ ACTION drain it and with correct fuel adjust to normal range wipe away replace clean When your unit seems to need further service, please consult with our service shop in your area. US-20