Rheem 13AJN Specifications - Page 22
Electrical and Physical Data
View all Rheem 13AJN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Electrical and Physical Data Air 13AJN Series Electrical and Physical Data ELECTRICAL PHYSICAL Model Number 13AJN Phase Frequency (Hz) Voltage (Volts) Compressor Rated Load Locked Rotor Amperes Amperes (RLA) (LRA) Fan Motor Full Load Amperes (FLA) Minimum Circuit Ampacity Amperes Fuse or HACR Circuit Breaker Minimum Maximum Amperes Amperes Outdoor Coil Face Area No. Sq. Ft. [m2] Rows CFM [L/s] Refrig. Per Circuit Oz. [g] Weight Net Shipping Lbs. [kg] Lbs. [kg] Rev. 5/17/2012 18 1-60-208/230 9/9 46 0.6 12/12 15/15 20/20 7.13 [0.66] 1 1415 [668] 67.4 [1911] 120 [54.4] 128 [54.4] 24 1-60-208/230 13.5/13.5 58.3 0.6 18/18 25/25 30/30 8.43 [0.78] 1 1665 [786] 67.8 [1922] 121 [54.9] 129 [54.9] 30 1-60-208/230 12.8/12.8 64 0.8 17/17 25/25 25/25 8.70 [0.81] 1 2075 [979] 75.0 [2126] 139 [63.1] 147 [63.1] 36 1-60-208/230 16.7/16.7 79 0.8 22/22 30/30 35/35 13.72 [1.27] 1 2540 [1199] 90.6 [2569] 149 [67.6] 157 [67.6] 42 1-60-208/230 17.9/17.9 112 1.2 24/24 30/30 40/40 13.72 [1.27] 1 2540 [1199] 106.0 [3005] 149 [67.6] 157 [67.6] 48 1-60-208/230 21.8/21.8 117 1.2 29/29 35/35 50/50 16.39 [1.52] 1 3290 [1553] 116.1 [3291] 188 [85.3] 192 [85.3] 60 1-60-208/230 26.4/26.4 134 1.2 35/35 45/45 60/60 19.17 [1.78] 1 3380 [1595] 157.2 [4457] 223 [101.2] 234 [101.2] ELECTRICAL PHYSICAL Model Number 13ACN Phase Frequency (Hz) Voltage (Volts) Compressor Rated Load Locked Rotor Amperes Amperes (RLA) (LRA) Fan Motor Full Load Amperes (FLA) Minimum Circuit Ampacity Amperes Fuse or HACR Circuit Breaker Minimum Maximum Amperes Amperes Outdoor Coil Face Area No. Sq. Ft. [m2] Rows CFM [L/s] Refrig. Per Circuit Oz. [g] Weight Net Shipping Lbs. [kg] Lbs. [kg] Rev. 5/17/2012 36 3-60-208/230 10.4/10.4 73 0.8 14/14 20/20 20/20 13.72 [1.27] 1 2540 [1199] 90.6 [2569] 149 [67.6] 157 [67.6] 42 3-60-208/230 13.2/13.2 88 1.2 18/18 25/25 30/30 13.72 [1.27] 1 2540 [1199] 106.0 [3005] 149 [67.6] 157 [67.6] 48 3-60-208/230 13.7/13.7 83.1 1.2 19/19 25/25 30/30 16.39 [1.52] 1 3290 [1553] 116.1 [3291] 188 [85.3] 192 [85.3] 60 3-60-208/230 16/16 110 1.2 22/22 30/30 35/35 19.17 [1.78] 1 3380 [1595] 157.2 [4457] 223 [101.2] 234 [101.2] ELECTRICAL PHYSICAL Model Number 13ADN Phase Frequency (Hz) Voltage (Volts) Compressor Rated Load Locked Rotor Amperes Amperes (RLA) (LRA) Fan Motor Full Load Amperes (FLA) Minimum Circuit Ampacity Amperes Fuse or HACR Circuit Breaker Minimum Maximum Amperes Amperes Outdoor Coil Face Area No. Sq. Ft. [m2] Rows CFM [L/s] Refrig. Per Circuit Oz. [g] Weight Net Shipping Lbs. [kg] Lbs. [kg] Rev. 5/17/2012 36 3-60-460 5.8/5.8 38 0.35 8/8 15/15 15/15 13.72 [1.27] 1 2540 [1199] 90.6 [2569] 149 [67.6] 157 [67.6] 42 3-60-460 6/6 44 0.8 9/9 15/15 15/15 13.72 [1.27] 1 2540 [1199] 106.0 [3005] 149 [67.6] 157 [67.6] 48 3-60-460 6.2/6.2 41 0.8 9/9 15/15 15/15 16.39 [1.52] 1 3290 [1553] 116.1 [3291] 188 [85.3] 192 [85.3] 60 3-60-460 7.8/7.8 52 0.8 11/11 15/15 15/15 19.17 [1.78] 1 3380 [1595] 157.2 [4457] 223 [101.2] 234 [101.2] ELECTRICAL PHYSICAL Model Number 13AYN Phase Frequency (Hz) Voltage (Volts) Compressor Rated Load Locked Rotor Amperes Amperes (RLA) (LRA) Fan Motor Full Load Amperes (FLA) Minimum Circuit Ampacity Amperes Fuse or HACR Circuit Breaker Minimum Maximum Amperes Amperes Outdoor Coil Face Area No. Sq. Ft. [m2] Rows CFM [L/s] Refrig. Per Circuit Oz. [g] Rev. 5/17/2012 Weight Net Shipping Lbs. [kg] Lbs. [kg] 48 3-60-575 4.8/4.8 33 0.8 7/7 15/15 15/15 16.39 [1.52] 1 3290 [1553] 116.1 [3291] 188 [85.3] 192 [85.3] 60 3-60-575 5.7/5.7 38.9 0.8 8/8 15/15 15/15 19.17 [1.78] 1 3380 [1595] 157.2 [4457] 223 [101.2] 234 [101.2] NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set. [ ] Designates Metric Conversions 22