Rheem Fury Electric Series Use and Care Manual - Page 11

Installation Checklist

Page 11 highlights

Installation Checklist A. Water Heater Location ❑ Close to area of heated water demand. ❑ Indoors and protected from freezing temperatures. ❑ Area free of flammable vapors. ❑ Provisions made to protect area from water damage. ❑ Sufficient room to service heater. B. Water Supply ❑ Water heater completely filled with water. ❑ Air purged from water heater and piping. ❑ Water connections tight and free of leaks. C. Relief Valve ❑ Temperature and Pressure Relief Valve properly installed and discharge line run to open drain. ❑ Discharge line protected from freezing. D. Wiring ❑ Power Supply voltage agrees with water heater rating plate. ❑ Branch circuit wire and fusing or circuit breaker of proper size. ❑ Electrical connections tight and unit properly grounded. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Installation Checklist
11
A. Water Heater Location
B. Water Supply
C.
Relief Valve
D.
Wiring
Close to area of heated water demand.
Indoors and protected from freezing
temperatures.
Area free of flammable vapors.
Provisions made to protect area from water
damage.
Sufficient room to service heater.
Water heater completely filled with water.
Air purged from water heater and piping.
Water connections tight and free of leaks.
Temperature and Pressure Relief Valve
properly installed and discharge line run to
open drain.
Discharge line protected from freezing.
Power Supply voltage agrees with water
heater rating plate.
Branch circuit wire and fusing or circuit
breaker of proper size.
Electrical connections tight and unit properly
grounded.