Rheem Power Direct Vent Series Specifications - Page 2
Air-Inlet Venting Information for PDV40 and PDV50, Air-Inlet Venting Information for PDV50-65, PDV65 - power direct vent
View all Rheem Power Direct Vent Series manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Residential Gas WI NaTtEeGrR AT ED HOME COMFORT Power Direct Vent Water Heaters Model PDV40 PDV40 PDV40 PDV50 PDV50 PDV50 Model PDV40 PDV40 PDV40 PDV40 PDV50 PDV50 PDV50 Model PDV40 PDV40 PDV40 PDV50 PDV50 Air-Inlet Venting Information for PDV40 and PDV50 Vent & Combustion Air-Inlet System Diameter (Inches) 2 3 3 2 3 3 From Sea Level Through 5,999 ft. Above Sea Level Minimum Allowed Equivalent Vent & Combustion Maximum Allowed Equivalent Vent & Combustion Air-Inlet Lengths - Each Pipe Run (Ft.) Air-Inlet Lengths - Each Pipe Run (Ft.) 7 30 7 60 7 50 7 30 7 60 7 50 Vent & Combustion Air-Inlet System Diameter (Inches) 2 2 3 3 2 3 3 From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level Minimum Allowed Equivalent Vent & Combustion Maximum Allowed Equivalent Vent & Combustion Air-Inlet Lengths - Each Pipe Run (Ft.) Air-Inlet Lengths - Each Pipe Run (Ft.) 7 15 7 30 7 60 7 50 7 15 7 60 7 50 Vent & Combustion Air-Inlet System Diameter (Inches) 2 3 3 3 3 From 7,701 ft. Above Sea Level Through 10,200 ft. Above Sea Level Minimum Allowed Equivalent Vent & Combustion Maximum Allowed Equivalent Vent & Combustion Air-Inlet Lengths - Each Pipe Run (Ft.) Air-Inlet Lengths - Each Pipe Run (Ft.) 7 15 7 60 7 50 7 60 7 50 Vent and Combustion Air-Inlet System Termination(s) 90° Elbows Concentric* 90° Elbows - - Concentric* 90° Elbows Concentric* 90° Elbows - - Concentric* Vent and Combustion Air-Inlet System Termination(s) 90° Elbows - - Concentric* 90° Elbows - - Concentric* - Concentric* 90° Elbows - - Concentric* Vent and Combustion Air-Inlet System Termination(s) - Concentric* 90° Elbows - - Concentric* 90° Elbows - - Concentric* Model PDV50-65 PDV50-65 PDV50-65 PDV65 PDV65 PDV65 PDV75 PDV75 PDV75 Air-Inlet Venting Information for PDV50-65, PDV65 and PDV75 Vent & Combustion Air-Inlet System Diameter (Inches) 3 3 4 3 3 4 3 3 4 From Sea Level Through 2,000 ft. Above Sea Level Minimum Allowed Equivalent Vent & Combustion Maximum Allowed Equivalent Vent & Combustion Air-Inlet Lengths - Each Pipe Run (Ft.) Air-Inlet Lengths - Each Pipe Run (Ft.) 7 50 7 40 7 100 8 50 8 40 8 100 8 50 8 40 8 100 Vent and Combustion Air-Inlet System Termination(s) 90° Elbows - - Concentric* 90° Elbows - 90° Elbows - - Concentric* 90° Elbows - 90° Elbows - - Concentric* 90° Elbows - Model PDV50-65 PDV50-65 PDV50-65 PDV65 PDV65 PDV65 PDV75 PDV75 PDV75 Vent & Combustion Air-Inlet System Diameter (Inches) 3 3 4 3 3 4 3 3 4 From 2,001 ft. Above Sea Level Through 5,999 ft. Above Sea Level Minimum Allowed Equivalent Vent & Combustion Maximum Allowed Equivalent Vent & Combustion Air-Inlet Lengths - Each Pipe Run (Ft.) Air-Inlet Lengths - Each Pipe Run (Ft.) 7 50 7 40 7 100 8 30 8 20 8 100 8 25 8 20 8 100 Vent and Combustion Air-Inlet System Termination(s) 90° Elbows - - Concentric* 90° Elbows - 90° Elbows - - Concentric* 90° Elbows - 90° Elbows - - Concentric* 90° Elbows - Model PDV50-65 PDV50-65 PDV50-65 PDV65 PDV75 Vent & Combustion Air-Inlet System Diameter (Inches) 3 3 4 4 4 From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level Minimum Allowed Equivalent Vent & Combustion Maximum Allowed Equivalent Vent & Combustion Air-Inlet Lengths - Each Pipe Run (Ft.) Air-Inlet Lengths - Each Pipe Run (Ft.) 7 50 7 40 7 100 8 40 8 50 Vent and Combustion Air-Inlet System Termination(s) 90° Elbows - - Concentric* 90° Elbows - 90° Elbows - 90° Elbows - Model PDV50-65 PDV50-65 PDV50-65 Vent & Combustion Air-Inlet System Diameter (Inches) 3 3 4 From 7,701 ft. Above Sea Level Through 10,200 ft. Above Sea Level Minimum Allowed Equivalent Vent & Combustion Maximum Allowed Equivalent Vent & Combustion Air-Inlet Lengths - Each Pipe Run (Ft.) Air-Inlet Lengths - Each Pipe Run (Ft.) 7 25 7 20 7 100 • One 90° elbow is approximately equivalent to 5 feet of pipe. One 45° elbow is approximately equivalent to 2.5 feet of pipe. * Use only Rheem 3 inch concentric termination. Vent and Combustion Air-Inlet System Termination(s) 90° Elbows - - Concentric* 90° Elbows - In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com IINNTTEEGGRRAATETDE DHOHMOEMCEOCMOFOMRFTO RT 2 PRINTED IN U.S.A. 05/12 WP FORM NO. 102-55 Rev. 4