Supplemental instructions for gas water heaters installed, in potable water/space heating

Page 18 highlights

Supplemental instructions for gas water heaters installed in potable water/space heating applications. Local codes or plumbing authority requirements may vary from the instructions or diagrams provided in this manual and take precedent over these instructions. Hot water supply to house Hot water supply to heating unit From HOT outlet on water heater Tee fitting for vertical hot water supply lines. Hot water supply to house From HOT outlet on water heater Hot water supply to heating unit Combination Potable Water and Space Heating Application Tee fitting must be installed as shown. This ensures that any air in the water lines will be purged through the domestic water faucets and showers. DANGER: When this system requires water for space heating at elevated temperatures (above 125°F [52°C.]), a mixing or tempering valve must be installed in the hot water supply line to the house in order to reduce the scald hazard potential. DANGER: Any piping or components used in the installation of this water heater in a combination potable and space heating application must be suitable for use with drinking water. DANGER: If this water heater is installed in an application intended to supply domestic hot water needs and hot water for space heating purposes, do not connect the heater to an existing heating unit or components of a heating system that have previously been used with a non drinking water system. Toxic chemicals such as those used for boiler treatment may be present and will contaminate the drinking water supply causing possible health risks. Never introduce toxic chemicals, such as those used for boiler treatment, into this system. Notice: 50' - 0" maximum distance from water heater to fan coil (developed length) is required for Massachusetts State. Tee fitting for horizontal hot water supply lines. Typical Piping Diagram for Combination Potable/Space Heating Installation Pressure Gauge Nominal 3/4" size mixing or tempering valve (refer to warning above). Follow mixing or tempering valve manufacturer's instructions for installation of the valve. Minimum of 2'-0" developed length of 3/4" pipe. Air vent 3/4" Tempered domestic hot water supply to house. 3/4" Check Valve with 1/8" Hole 3/4" Shut-Off Valve (Typ.) 3/4" cold water supply Spring loaded check valve in heating unit hot water supply line and cold water return line (not supplied with water heater) NOTE: This check valve is incorporated in some heating units. Refer to the installation instructions supplied with specific heating unit to determine if it is required. Isolation valve in hot water supply line to heating unit (not supplied with water heater) 3/4" ShutOff Valve (Typ.) 3/4" Shut-Off Valve (Typ.) Heat Trap 6" Min. 2 Gallon Thermal Expansion Tank (if required-not supplied with water heater) See diagrams above for proper pipe application for vertical or horizontal supply lines. Temperature and Pressure Relief Valve, tie to location approved by local code 140° 120° to 130° Hot water to space heater Hot water coil All bronze pump. Check valve internal in pump. Air bleed valve. Water Sample Tap. Gas line to water heater Temperature and pressure relief valve discharge line Gas Control (Thermostat) Gas Fired Water Heater Water Heater drain pan installed in accordance with the Local and State Code Water Heater to be installed in accordance with the Local and State Energy Code All water piping shall be insulated in accordance with Local and State Energy Code. 18 3/4" HWS & HWR to Heating Coil. Drain valve (not supplied with water heater) Isolation valve in cold water return line from heating unit (not supplied with water heater) Gas Direct Vent discharge must comply with Local and State Codes Combustion Air Inlet Openings Vacuum Relief Valve (Not Supplied) 6" Air Gap If required, install per local codes and valve manufacturer's instructions. Air Handler To HVAC Unit. T FAN ON OFF HEAT COOL Electronically controlled pump timer. Activates every 6 hours for 60 seconds. Wire to bronze pump.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Typical Piping Diagram for Combination Potable/Space Heating Installation
Spring loaded check valve in heating unit
hot water supply line and cold water return
line (not supplied with water heater)
NOTE: This check valve is incorporated
in some heating units. Refer to the
installation instructions supplied with
specific heating unit to determine if it is
required.
All water piping shall be insulated in
accordance with Local and State Energy
Code.
Isolation valve in
cold water return line
from heating unit (not
supplied with water
heater)
Nominal 3/4" size mixing or tempering valve
(refer to warning above).
Follow mixing or
tempering valve manufacturer’s instructions for
installation of the valve.
Temperature and pressure relief
valve discharge line
Air Handler
Drain valve
(not supplied with
water heater)
Hot water
to space heater
Temperature and Pressure Relief
Valve, tie to location approved by
local code
See diagrams above for proper
pipe application for vertical
or horizontal supply lines.
Isolation valve in hot water supply line
to heating unit (not supplied with water
heater)
3/4" cold water supply
3/4" Tempered
domestic hot water
supply to house.
Gas line to water heater
6” Air Gap
Combustion Air Inlet
Openings
2 Gallon Thermal
Expansion Tank (if
required-not supplied
with water heater)
Air vent
Heat Trap
6” Min.
3/4" Shut-Off Valve (Typ.)
3/4" Check Valve with 1/8" Hole
Pressure Gauge
3/4" Shut-Off Valve (Typ.)
3/4" Shut-
Off Valve
(Typ.)
Hot water coil
All bronze pump.
Check valve
internal in pump.
Air bleed valve.
Water Sample Tap.
T
FAN
ON
OFF
HEAT
COOL
To HVAC Unit.
Electronically controlled pump timer.
Activates every 6 hours for 60 seconds.
Wire to bronze pump.
3/4" HWS & HWR
to Heating Coil.
Minimum of 2'-0" developed length
of 3/4" pipe.
Water Heater drain pan installed in
accordance with the Local and State
Code
Water Heater to be installed in
accordance with the Local and State
Energy Code
Gas Fired
Water Heater
Gas Direct Vent discharge
must comply with Local
and State Codes
Vacuum Relief Valve
(Not Supplied)
If required, install per local codes
and valve manufacturer’s
instructions.
120° to 130°
140°
Gas
Control (Thermostat)
Tee fitting for vertical hot
water supply lines.
Hot water
supply to
house
From HOT
outlet on
water heater
Hot water
supply to
heating
unit
Supplemental instructions for gas water heaters installed
in potable water/space heating applications.
Local codes or plumbing authority requirements may vary from the instructions or diagrams provided
in this manual and take precedent over these instructions.
Tee fitting for horizontal hot
water supply lines.
From HOT
outlet on
water heater
Hot water
supply to
house
Hot water supply
to heating unit
Combination Potable Water and Space Heating Application
Tee fitting must be installed as shown.
This ensures that any air in the water lines
will be purged through the domestic water
faucets and showers.
DANGER: When this system
requires water for space heating at
elevated temperatures (above 125°F
[52°C.]), a mixing or tempering valve
must be installed in the hot water
supply line to the house in order to
reduce the scald hazard potential.
DANGER: Any piping or components
used in the installation of this water
heater in a combination potable and
space heating application must be
suitable for use with drinking water.
DANGER
:
If this water heater is
installed in an application intended to
supply domestic hot water needs and
hot water for space heating purposes,
do not connect the heater to an existing
heating unit or components of a heating
system that have previously been used
with a non drinking water system. Toxic
chemicals such as those used for boiler
treatment may be present and will
contaminate the drinking water supply
causing possible health risks. Never
introduce toxic chemicals, such as those
used for boiler treatment, into this
system.
Notice:
50' - 0" maximum distance from
water heater to fan coil (developed length)
is required for Massachusetts State.
18