IMPORTANT SAFETY INSTRUCTIONS  Batteries can explode in the presence of a source of ignition, such as a pilot light. To reduce the risk of serious personal injury, never use any cordless product in the presence of open flame. An exploded battery can propel debris and chemicals. If exposed, flush with water immediately.  Do not crush, drop or damage battery pack. Do not use a battery pack or charger that has been dropped or received a sharp blow. A damaged battery is subject to explosion. Properly dispose of a dropped or damaged battery immediately. Failure to heed this warning can result in serious personal injury.  Do not abuse cord. Never use the cord to carry the light. Do not pull the light cord rather than the plug when disconnecting from receptacle. Damage to the cord or light could occur and create an electric shock hazard. Replace damaged cords immediately.  Save these instructions. Refer to them frequently and use them to instruct others who may use this tool. If you loan someone this tool, loan them these instructions also. ELECTRICAL DOUBLE INSULATION Double insulation is a concept in safety in electric products, which eliminates the need for the usual three-wire grounded power cord. All exposed metal parts are isolated from the internal metal motor components with protecting insulation. Double insulated products do not need to be grounded. WARNING: the minimum wire size required in an extension cord. Only round jacketed cords listed by Underwriter's Laboratories (UL) should be used. Use an extension cord that is designed for outside use. This type of cord is designated with "WA" or "W" on the cord's jacket. Before using any extension cord, inspect it for loose or exposed wires and cut or worn insulation. The double insulated system is intended to protect the user from shock resulting from a break in the product's internal wiring. Observe all normal safety precautions to avoid electrical shock. **Ampere rating (on product data plate) 0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0 Cord Length Wire Size (A.W.G.) 25´ 16 16 16 16 14 14 NOTE: Servicing of a product with double insulation requires 50´ 16 16 16 14 14 12 extreme care and knowledge of the system and should 100´ 16 16 14 12 10 - be performed only by a qualified service technician. For service, we suggest you return the product to your nearest authorized service center for repair. Always use original **Used on 12 gauge - 20 amp circuit NOTE: AWG = American Wire Gauge factory replacement parts when servicing. ELECTRICAL CONNECTION This product should be connected to a power supply that is 120 volts, AC only (normal household current), 60 Hz. Do not operate this product on direct current (DC) through the power cord. A substantial voltage drop will cause a loss of power and the product will overheat. If the product does not operate when plugged into an outlet, double-check the power supply. WARNING: Keep the extension cord clear of the working area. Position the cord so that it will not get caught on lumber, tools, or other obstructions while you are working with this product. Failure to do so can result in serious personal injury. EXTENSION CORDS WARNING: When using a product at a considerable distance from a power source, be sure to use an extension cord that has the capacity to handle the current the product will draw. An undersized cord will cause a drop in line voltage, resulting in Check extension cords before each use. If damaged replace immediately. Never use a product with a damaged cord since touching the damaged area could cause electrical shock resulting in serious injury. overheating and loss of power. Use the chart to determine 3 - English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

3 – English
the minimum wire size required in an extension cord. Only
round jacketed cords listed by Underwriter’s Laboratories
(UL) should be used.
Use an extension cord that is designed for outside use. This
type of cord is designated with “WA” or “W” on the cord’s
jacket.
Before using any extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
**Ampere rating (on product data plate)
0-2.0
2.1-3.4
3.5-5.0
5.1-7.0
7.1-12.0 12.1-16.0
Cord Length
Wire Size (A.W.G.)
25´
16
16
16
16
14
14
50´
16
16
16
14
14
12
100´
16
16
14
12
10
**Used on 12 gauge - 20 amp circuit
NOTE:
AWG = American Wire Gauge
WARNING:
Keep the extension cord clear of the working area. Po-
sition the cord so that it will not get caught on lumber,
tools, or other obstructions while you are working with
this product. Failure to do so can result in serious per-
sonal injury.
WARNING:
Check extension cords before each use. If damaged
replace immediately. Never use a product with a dam-
aged cord since touching the damaged area could cause
electrical shock resulting in serious injury.
DOUBLE INSULATION
Double insulation is a concept in safety in electric products,
which eliminates the need for the usual three-wire grounded
power cord. All exposed metal parts are isolated from the
internal metal motor components with protecting insulation.
Double insulated products do not need to be grounded.
WARNING:
The double insulated system is intended to protect the
user from shock resulting from a break in the product’s
internal wiring. Observe all normal safety precautions to
avoid electrical shock.
NOTE:
Servicing of a product with double insulation requires
extreme care and knowledge of the system and should
be performed only by a qualified service technician. For
service, we suggest you return the product to your nearest
authorized service center for repair. Always use original
factory replacement parts when servicing.
ELECTRICAL CONNECTION
This product should be connected to a
power supply that
is 120 volts, AC only (normal household current), 60 Hz
.
Do not operate this product on direct current (DC) through
the power cord. A substantial voltage drop will cause a loss
of power and the product will overheat. If the product does
not operate when plugged into an outlet, double-check the
power supply.
EXTENSION CORDS
When using a product at a considerable distance from a
power source, be sure to use an extension cord that has
the capacity to handle the current the product will draw. An
undersized cord will cause a drop in line voltage, resulting in
overheating and loss of power. Use the chart to determine
ELECTRICAL
Batteries can explode in the presence of a source
of ignition, such as a pilot light.
To reduce the risk of
serious personal injury, never use any cordless product
in the presence of open flame. An exploded battery can
propel debris and chemicals. If exposed, flush with water
immediately.
Do not crush, drop or damage battery pack. Do not
use a battery pack or charger that has been dropped
or received a sharp blow.
A damaged battery is subject
to explosion. Properly dispose of a dropped or damaged
battery immediately. Failure to heed this warning can
result in serious personal injury.
Do not abuse cord.
Never use the cord to carry the
light. Do not pull the light cord rather than the plug when
disconnecting from receptacle. Damage to the cord or
light could occur and create an electric shock hazard.
Replace damaged cords immediately.
Save these instructions.
Refer to them frequently and
use them to instruct others who may use this tool. If you
loan someone this tool, loan them these instructions also.