RY905500E QUICK REFERENCE GUIDE WARNING: This Quick Reference Guide is not a substitute for reading the operator's manual. To reduce the risk of injury or death, user must read and understand operator's manual before using this product. All page references refer to the operator's manual. IMPORTANT! WARNING: Do not connect to a building's electrical system unless the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician. The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes. Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far away from windows, doors, and vents. TOOLS NEEDED Socket Wrenches, Phillips Screwdriver, and an Adjustable Wrench FIRST TIME ASSEMBLY 1 Install the feet (see page 11). 4 Raise the handle (see page 13). 2 Install the wheels (see page 12). 5 Add entire bottle of lubricant provided to the generator (see page 14). 3 Connect the battery (see page 12). STARTING THE UNIT USING THE GENERATOR 1 Add fuel (see page 14). NOTICE: Do not use E15 or E85 fuel in this product. It is a violation of federal law and will damage the unit and void your warranty. Only use unleaded gasoline containing up to 10% ethanol. 3 Press the start button to start the engine.Engine can also be started by pulling the recoil starting grip until the engine runs. (See page 15) 1 Connect devices to be powered by generator by following the steps below (see pages 8-9). • Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you will power at the same time. See page 9 for how to calculate total amount of power needed. • Start the generator with nothing connected. • Plug in and turn on the first load, preferably the largest load you have. • Permit the generator output to stabilize (engine runs smoothly and attached device operates properly). • Plug in and turn on the next load. • Again, permit the generator to stabilize. • Repeat previous two steps for each additional load. IMPORTANT: Never add more loads than the generator capacity. Take special care to consider surge loads in generator capacity. (See pages 8-9.) STORING THE UNIT OR PULL RECOIL STARTER TO START 11 When preparing to store the generator, allow the unit to cool completely, then follow the guidelines listed on page 19. TROUBLESHOOTING This is a 4-cycle engine. Do not mix fuel and lubricant ­together. Mix fuel stabilizer with gasoline according to manufacturer's directions prior to filling the tank. 2 Verify the run switch is in the ON position, then place the engine switch/fuel valve/choke lever in the START position (see page 15). RUN SWITCH ON START 4 Allow engine to run for 15-30 seconds, then move the engine switch/fuel valve/choke lever to the RUN position (see page 15). 15-30 S 15-30 S RUN STOPPING THE UNIT 1 Place the engine switch/fuel valve/choke lever in the OFF position (see page 15). OFF PROBLEM Engine will not start. Engine hard to start. POSSIBLE CAUSE SOLUTION Run switch is in the OFF position. Turn run switch ON. No fuel. Fill fuel tank. Stale gasoline or water in gasoline. Drain entire system and refill with fresh fuel. Lubricant level is low. Engine is equipped with Low Oil Shutoff. If engine lubricant level is low, it must be filled before unit will start. Check engine lubricant level and fill, if n­ ecessary. Spark plug faulty, fouled, or improperly Replace spark plug. gapped. Engine switch/fuel valve/choke lever is in Move engine switch/fuel valve/choke lever OFF or RUN position. to START position. Engine stored without treating or draining Drain fuel and carburetor. Refuel with fresh gasoline, or refueled with bad gasoline. gasoline. Dirty fuel filter. Replace fuel filter or contact a qualified service center. Water in gasoline. Drain entire system and refill with fresh fuel. Weak spark at spark plug. Replace spark plug or contact a qualified service center. Engine lacks power. Dirty air filter. Check air filter element. Clean or ­replace as needed. Engine stored without treating or draining Drain fuel and carburetor. Refuel with fresh gasoline, or refueled with bad gasoline. gasoline. Electric start feature not working. Engine switch/fuel valve/choke lever is in Move engine switch/fuel valve/choke lever to OFF position. START or RUN position. Battery wires are disconnected. Connect the battery wires. Battery is not charged. Charge the battery. Engine battery charge circuit fuse is blown. Replace the engine battery charge circuit fuse. AC receptacle does not work. Circuit breaker is tripped. Reset the AC circuit breaker. GFCI is tripped. Reset the GFCI. Item plugged in is defective. Try a different item. Generator makes a "spark knock" or "ping- An occasional light "knocking" or "pinging" Switch to a different brand of gasoline, ing" noise. under heavy load is not a cause for concern. making sure that the octane rating is 86 However, if the knocking or pinging oc- or higher. If problem continues, contact a curs under normal load at a steady engine qualified service center. speed, the problem may be with the brand of gasoline being used. If problem persists after trying the above solutions, contact customer service or a qualified service center for assistance. NOTICE: As the equipment owner, you are responsible for the performance of the required maintenance listed in the Maintenance section It is recommended that you retain all receipts covering maintenance on your equipment. Neglecting or failing to perform the required maintenance may increase emissions, decrease fuel efficiency, degrade performance, cause irreversible engine damage and/or void your warranty. Make the most of your purchase! Go to www.ryobitools.com and register your new tool online. For questions about o­ perating or maintaining your product, please call 1-800-860-4050. Set unit on flat surface so engine is level. Remove dipstick, wipe clean, put back in hole (but don't screw in) and check lubricant level. 991000747 11-17-15 (REV:02)

  • 1

991000747
11-17-15 (REV:02)
Install the feet
(see page 11).
WARNING:
This Quick Reference Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and understand operator’s manual before using this product. All page references refer to
the operator’s manual.
FIRST TIME ASSEMBLY
1
RY905500E QUICK REFERENCE GUIDE
STARTING THE UNIT
USING THE GENERATOR
2
5
Install the wheels
(see page 12).
Add entire bottle of lubricant provided to the
generator
(see page 14).
Add fuel
(see page 14).
1
2
Verify the run switch is in the ON position, then
place the engine switch/fuel valve/choke lever in
the START position
(see page 15).
Set unit on flat surface so engine is level.
Remove dipstick, wipe clean, put back in hole
(but don’t screw in) and check lubricant level.
This is a 4-cycle engine. Do not mix fuel and
lubricant together.
Mix fuel stabilizer with gasoline according to
manufacturer’s directions prior to filling the
tank.
START
TOOLS NEEDED
4
Raise the handle
(see page 13).
STOPPING THE UNIT
Place the engine switch/fuel valve/choke lever in the OFF position
(see page 15).
1
Connect devices to be powered by generator by following the steps below
(see pages 8-9).
Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you
will power at the same time. See page 9 for how to calculate total amount of power needed.
Start the generator with nothing connected.
Plug in and turn on the first load, preferably the largest load you have.
Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).
Plug in and turn on the next load.
Again, permit the generator to stabilize.
Repeat previous two steps for each additional load.
IMPORTANT: Never add more loads than the generator capacity. Take special care to consider surge loads in
generator capacity.
(See pages 8-9.)
1
WARNING:
Do not connect to a building’s electrical
system unless the generator and transfer
switch have been properly installed and
the electrical output has been verified by
a qualified electrician. The connection
must isolate the generator power from
utility power and must comply with all
applicable laws and electrical codes.
IMPORTANT!
Only use OUTSIDE and
far away from windows,
doors, and vents.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
3
Press the start button to start the engine.Engine can
also be started by pulling the recoil starting grip
until the engine runs.
(See page 15)
TROUBLESHOOTING
STORING THE UNIT
When preparing to store the generator, allow the unit to cool completely, then follow the guidelines listed on
page 19.
1
PROBLEM
POSSIBLE CAUSE
SOLUTION
Engine will not start.
Run switch is in the
OFF
position.
No fuel.
Stale gasoline or water in gasoline.
Lubricant level is low.
Spark plug faulty, fouled, or improperly
gapped.
Engine switch/fuel valve/choke lever is in
OFF
or
RUN
position.
Engine stored without treating or draining
gasoline, or refueled with bad gasoline.
Dirty fuel filter.
Turn run switch
ON
.
Fill fuel tank.
Drain entire system and refill with fresh fuel.
Engine is equipped with Low Oil Shutoff.
If engine lubricant level is low, it must be
filled before unit will start. Check engine
lubricant level and fill, if necessary.
Replace spark plug.
Move engine switch/fuel valve/choke lever
to
START
position.
Drain fuel and carburetor. Refuel with fresh
gasoline.
Replace fuel filter or contact a qualified
service center.
Engine hard to start.
Water in gasoline.
Weak spark at spark plug.
Drain entire system and refill with fresh fuel.
Replace spark plug or contact a qualified
service center.
Engine lacks power.
Dirty air filter.
Engine stored without treating or draining
gasoline, or refueled with bad gasoline.
Check air filter element. Clean or replace
as needed.
Drain fuel and carburetor. Refuel with fresh
gasoline.
Electric start feature not working.
Engine switch/fuel valve/choke lever is in
OFF
position.
Battery wires are disconnected.
Battery is not charged.
Engine battery charge circuit fuse is blown.
Move engine switch/fuel valve/choke lever to
START
or
RUN
position.
Connect the battery wires.
Charge the battery.
Replace the engine battery charge circuit fuse.
AC receptacle does not work.
Circuit breaker is tripped.
GFCI is tripped.
Item plugged in is defective.
Reset the AC circuit breaker.
Reset the GFCI.
Try a different item.
Generator makes a “spark knock” or “ping-
ing” noise.
An occasional light “knocking” or “pinging”
under heavy load is not a cause for concern.
However, if the knocking or pinging oc-
curs under normal load at a steady engine
speed, the problem may be with the brand
of gasoline being used.
Switch to a different brand of gasoline,
making sure that the octane rating is 86
or higher. If problem continues, contact a
qualified service center.
If problem persists after trying the above solutions, contact customer service or a qualified service center for assistance.
NOTICE:
As the equipment owner, you are responsible for the performance of the required maintenance listed in the
Maintenance
section It is recommended that you retain all receipts covering maintenance on your equipment. Neglecting or failing to
perform the required maintenance may increase emissions, decrease fuel efficiency, degrade performance, cause irreversible
engine damage and/or void your warranty.
Socket Wrenches, Phillips Screwdriver, and an Adjustable Wrench
NOTICE:
Do not use E15 or E85 fuel in this prod-
uct. It is a violation of federal law and will
damage the unit and void your warranty.
Only use unleaded gasoline containing
up to 10% ethanol.
Make the most of your purchase! Go to www.ryobitools.com
and register your new tool online. For questions about operating
or maintaining your product, please call 1-800-860-4050.
3
Connect the battery
(see page 12).
Allow engine to run for 15–30 seconds, then move
the engine switch/fuel valve/choke lever to the
RUN position
(see page 15).
4
RUN
15-30 S
OR PULL RECOIL STARTER TO START
OFF
RUN SWITCH ON