Samsung AX300T9080 User Manual - Page 34
Pollution level, Display, The PM10, PM2.5, PM1.0 levels the all same.
View all Samsung AX300T9080 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Before Requesting Service Pollution level Display The fan speed does not change when the pollution level changes. • Set the fan speed to Auto. The fan speed does not change automatically when it is set to Low , Medium, or High or when the Wind-Free or Sleep mode is running. The PM10, PM2.5, PM1.0 levels do not change from Good (05). • This may happen when the room is properly sealed and the air is clean. To check if the sensor is functioning, test it by tearing paper by the sensor and/or rub them to create some dust. This will cause the PM levels to change if the sensor is working properly. -- Dusting off or cleaning the room may not necessarily cause sensor feedback if the dust particles are bigger than PM10, while they are still filtered and removed from the air. The PM10, PM2.5, PM1.0 levels the all same. • When the air is clean, you may not see a difference between the PM10, PM2.5 and PM1.0 levels. To check if the sensor is functioning, test it by tearing paper by the sensor and/or rub them to create some dust. This will cause the PM levels to change if the sensor is working properly. The filter replacement indicator is always turned on. • Replace the filters with new ones, and then press and hold the [ ] button for 3 seconds or more to reset the filter replacement reminder. Strange indications appear on the display. • If any of the indications C103, C154, C162, C163 appears, contact a Samsung Service Center. Appendix 34 English