Samsung DV42H5600EP/A3 Trouble Shooting Guide Tech Manual (English, French, Sp - Page 9

WARNING, Sensor Bars & temperature sensor check

Page 9 highlights

TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. Sensor Bars & temperature sensor check Sensor Bars - Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5. Approx ∞ Ω without laundry Approx 190 Ω ± 10 % with wet clothes Cycling Thermistor 1 - Disconnect harness and test Blue wire Pin 3 to Red wire Pin 6. Approx 10 KΩ at 25 °C / 77 °F Vent Thermistor 2 (Vent sensor model only) Disconnect harness and test Yellow wire Pin 2 to White wire Pin 7. Approx 238.23 KΩ at 25 °C / 77 °F 9 Technical_information-03382A_EN_131209.indd 9 2013-12-09 �� 5:37:36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

9
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Sensor Bars & temperature sensor check
Sensor Bars
- Disconnect harness and test Pink
wire Pin 4 to Orange wire Pin 5.
Approx ∞ Ω without laundry
Approx 190 Ω ± 10 % with wet clothes
Cycling Thermistor 1
- Disconnect harness and
test Blue wire Pin 3 to Red wire Pin 6.
Approx 10 KΩ at 25 °C / 77 °F
Vent Thermistor 2 (Vent sensor model only)
-
Disconnect harness and test
Yellow wire Pin 2 to White wire Pin 7.
Approx 238.23 KΩ at 25 °C / 77 °F