Samsung DV431AEW/XAA User Manual (user Manual) (ver.1.0) (English) - Page 11

Alcove Or Closet Installation - dryer 01

Page 11 highlights

01 installing your dryer ALCOVE OR CLOSET INSTALLATION MINIMUM CLEARANCES FOR CLOSET AND ALCOVE INSTALLATIONS: Sides - 1 in / 25 mm Top - 17 in / 432 mm Rear - 4 in / 102 mm Closet Front - 2 in / 51 mm If the washer and dryer are installed together, the closet front must have at least a 72 in² (465 cm²) unobstructed air opening. A 1 in. (2.5 cm) B 17 in. (43.2 cm) 1 in. (2.5 cm) 27 in. (68.6 cm) 27 in. (68.6 cm) A. Recessed area B. Side view - closet or confined area 1 in. (2.5 cm) 2 in. (5 cm) 31.9 in. (81.1 cm) 4 in. (10.2 cm) DV431AEP-03021A-01_EN.indd Sec5:11 installing your dryer _11 2011-02-08 11:27:39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

installing your dryer
_11
ALCOVE OR CLOSET INSTALLATION
MINIMUM CLEARANCES FOR CLOSET AND ALCOVE INSTALLATIONS:
Sides – 1 in / 25 mm
Rear – 4 in / 102 mm
Top – 17 in / 432 mm
Closet Front – 2 in / 51 mm
If the washer and dryer are installed together, the closet front must have at least a 72 in² (465
cm²) unobstructed air opening.
A. Recessed area
B. Side view - closet or confined area
01 installing your dryer
B
2 in.
(5 cm)
31.9 in.
(81.1 cm)
4 in.
(10.2 cm)
17 in.
(43.2 cm)
A
1 in.
(2.5 cm)
27 in.
(68.6 cm)
1 in.
(2.5 cm)
1 in.
(2.5 cm)
27 in.
(68.6 cm)
DV431AEP-03021A-01_EN.indd Sec5:11