Samsung DV45H6300EW/A3 Trouble Shooting Guide Tech Manual (English, French, Sp - Page 3

TEST MODE, Data Display Mode, Smart Install, WARNING - dryer

Page 3 highlights

ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. TEST MODE Data Display Mode How to Enter: - In normal mode, press Drylevel  Time  Temp  Time in less than 2 seconds to enter the display mode. - To change the mode, use the cycle selector dial. Definition of Data Display Mode: - Display Mode 1 : Main micom version - Display Mode 2 : display micom version - Display Mode 3 : touch module version - Display Mode 4 : option value - Display Mode 5 : Temperature data - Display Mode 6 : Average temperature data for 1 minute - Display Mode 7 : Temperature data for detecting vent clog up - Display Mode 8 : Average touch sensor data for 1 minute - Display Mode 9 : cycle count Smart Install This allows service personnel to check if the dryer is installed properly. To enter this mode Turn on the product, and press and hold the Adjust Time Up + Temp key for 7 seconds. A message of "SC" appears on the display. 1. Checking the touch sensor Enter the Smart Install mode, and open the door. The state of the touch sensor appears on the display. 0 : Touch sensor open 1 : Touch sensor short Put a wet cloth on the touch sensor to display "1". Releasing it displays "0". 2. Checking the motor and the heater After checking the touch sensor is complete, press the Start button to enter the checking mode. When the checking is complete, the results appear on the display. OK : Both motor and heater work normally HE : Motor or heater doesn't work normally To exit the Smart Install mode, turn off the product. Error Recall Mode The Error Recall mode reminds users of the latest error that appeared. Press and hold both the Wrinkle prevent + Dry Level keys for more than 7 seconds to enter this mode. In the Error Recall mode, the most recent error that occurred is displayed. If there is no recent error, nothing is displayed. 3 Technical_information-03382A_EN_131209.indd 3 2013-12-09 �� 5:37:31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

3
TEST MODE
Data Display Mode
How to Enter:
-
In normal mode, press
Drylevel
Time
Temp
Time
in less than 2 seconds to enter the
display mode.
-
To change the mode, use the cycle selector dial.
Definition of Data Display Mode:
-
Display Mode 1 : Main micom version
-
Display Mode 2 : display micom version
-
Display Mode 3 : touch module version
-
Display Mode 4 : option value
-
Display Mode 5 : Temperature data
-
Display Mode 6 : Average temperature data for 1 minute
-
Display Mode 7 : Temperature data for detecting vent clog up
-
Display Mode 8 : Average touch sensor data for 1 minute
-
Display Mode 9 : cycle count
Smart Install
This allows service personnel to check if the dryer is installed properly.
To enter this mode
Turn on the product, and press and hold the
Adjust Time Up + Temp
key for 7 seconds.
A message of “SC” appears on the display.
1.
Checking the touch sensor
Enter the Smart Install mode, and open the door. The state of the touch sensor appears on the
display.
0
: Touch sensor open
1
: Touch sensor short
Put a wet cloth on the touch sensor to display "
1
". Releasing it displays "
0
".
2.
Checking the motor and the heater
After checking the touch sensor is complete, press the Start button to enter the checking
mode. When the checking is complete, the results appear on the display.
OK
: Both motor and heater work normally
HE
: Motor or heater doesn't work normally
To exit the Smart Install mode, turn off the product.
Error Recall Mode
The Error Recall mode reminds users of the latest error that appeared.
Press and hold both the
Wrinkle prevent + Dry Level
keys for more than 7 seconds to enter this mode.
In the Error Recall mode, the most recent error that occurred is displayed. If there is no recent error,
nothing is displayed.