Step 4
View all Samsung DV45K6200EW/A3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Installation Installation • A strain relief must be used. Do not loosen the nuts already installed on the terminal block. Be sure they are tight. Use a 3/8" (1 cm) deep well socket. STEP 4 Connect the water hose (applicable models only) The dryer must be connected to a cold water tap using the provided water hoses. 1. Close the cold water tap. If you have a washer cold water hose attached to the cold water faucet, unscrew and remove the hose. Then, connect the female end of the Y connector to the cold water tap. 2. Connect the straight end of the water hose to the Y connector. Tighten the hose coupling by hand. 3. Using pliers, tighten the coupling an additional two-thirds turn. Do not overtighten. You can damage the coupling. 4. Connect the angled end of the water hose to the filling valve at the bottom rear of the dryer. Turn the coupling by hand until it is tight. 5. Using pliers, tighten the coupling an additional two-thirds turn. Do not overtighten. You can damage the coupling. 6. If you detached the cold water hose from your washer, attach the hose to the open end of the Y connector, tighten the coupling by hand until it is tight, and then, using a pliers, tighten an additional two-thirds turn. 7. Open the cold water tap, and then check for any leaks. If the Y connector cannot be directly connected to the cold water tap, use the short hose as shown on the following page. 24 English DV7500K-03381C-02_EN.indd 24 4/7/2016 5:05:45 PM