Samsung DV48J7770EW/A2 User Manual - Page 51

Information codes

Page 51 highlights

Information codes If the dryer fails to operate, you may see an information code on the screen. Check the table below and try the suggestions. No Code Action Operating the dryer with the door open. 1 dC • Make sure the door is properly closed. • Make sure laundry is not caught in the door. Invalid power source frequency • Check if you are using regular power source frequencies. 2 FC • Check the power frequency sensor circuit. • Try restarting the cycle. • If the information code remains, contact a customer service centre. Electronic control problem (Invalid Communication). 3 AC • First check the PCB and wire harness. • If the information code remains, contact a customer service centre. Malfunction is detected in the motor relay circuit. 4 3C • Check the motor connection cable. • Check the motor relay operation of the PCB. • Check the drum belt. 5 bC2 Incorrect button state. • If the display PCB key circuit is shorted or not. 6 HC High temperature heating check • Clean the filter case or condenser. 7 HC4 • If the information code remains, contact a customer service centre.(enter the line test mode). The electronic control needs to be checked (Over Voltage Error). 8 9C1 • Check the PCB and wire harness. • Check if power is supplied properly. • If the information code remains, contact a customer service centre. The Thermistor1 resistance is very low or high. 9 tC • Check for a clogged lint screen • Check if the vent system is restricted or . • Check Thermistor1 resistance. The Thermistor2 resistance is very low or high. 10 tC5 • Check for a clogged lint screen. • Check if the vent system is restricted. • Check Thermistor2 resistance. Maintenance %7+2@&/64JOEE English 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

English 51
Maintenance
Information codes
If the dryer fails to operate, you may see an information code on the screen. Check the table
below and try the suggestions.
No
Code
Action
1
dC
Operating the dryer with the door open.
• Make sure the door is properly closed.
• Make sure laundry is not caught in the door.
2
FC
Invalid power source frequency
• Check if you are using regular power source frequencies.
• Check the power frequency sensor circuit.
• Try restarting the cycle.
• If the information code remains, contact a customer service centre.
3
AC
Electronic control problem (Invalid Communication).
• First check the PCB and wire harness.
• If the information code remains, contact a customer service centre.
4
3C
Malfunction is detected in the motor relay circuit.
• Check the motor connection cable.
• Check the motor relay operation of the PCB.
• Check the drum belt.
5
bC2
Incorrect button state.
• If the display PCB key circuit is shorted or not.
6
HC
High temperature heating check
• Clean the filter case or condenser.
• If the information code remains, contact a customer service centre.(enter
the line test mode).
7
HC4
8
9C1
The electronic control needs to be checked (Over Voltage Error).
• Check the PCB and wire harness.
• Check if power is supplied properly.
• If the information code remains, contact a customer service centre.
9
tC
The Thermistor1 resistance is very low or high.
• Check for a clogged lint screen
• Check if the vent system is restricted or .
• Check Thermistor1 resistance.
10
tC5
The Thermistor2 resistance is very low or high.
• Check for a clogged lint screen.
• Check if the vent system is restricted.
• Check Thermistor2 resistance.
DV7700J-03170Q-05_EN-US.indd
51
2015/11/3